h/p/cosmos vakumlu koşu bandı All models error codes
Codes
- E21Error codeError of elevation system
- E30Error codeError of speed / distance measurement
- E31Error code+ tolerance aberration speed sensor The measured speed-value (actual value) is higher than the calculated value (debit-value) (at least with the percentage set in administrator OP12 )
- E32Error code- tolerance aberration speed sensor The measured speed-value (actual value) is lower than the calculated value (debit-value) (at least with the percentage set in administrator OP12 )
- E41Error codeError during memory initialization “SETUP ERROR“ MCU or low or defective battery
- E50Error codeError of frequency inverter / motor regulation At ANALOG control of frequency inverter
- E51Error codeError of frequency inverter/ motor regulation Signal error between MCU5 and frequency inverter. Only applicable at digital control (RS485) of MCU5/frequency inverter
- E52Error codeError of RS485 cable motor control Cable defect or bad contact at the connection MCU/frequency inverter Only applicable for digital control (RS485) of MCU5/frequency inverter
- E121Error codeelevation error increments
- E130Error codespeed error increments
- E151Error codeFU error response
- E152Error codeFU communication timeout
- E153Error codeinternal communication error
- E155Error codeinternal communication error response
- E156Error codeinternal communication error general
- Err01Error codeError chip card drive (not all models)
- Err02Error codeError chip card drive (not all models)
- Err03Error codeError chip card drive (not all models)
- Err04Error codeError chip card drive (not all models)
- OP01Error codeIf for example the E.02 service-time-interval is being set back with this operation, the distance-interval is not set back and vice versa! Only administrator option OP 47 resets all three values simultaneously
- OP03Error codeIndication of total hours of operation = stand-by-time including runtime of motor/ running belt (h)
- OP04Error codeIndication of total hours of runtime of motor/running belt (h)
- OP06Error codecurrent date/time
- OP11Error codeActivating and de-activating speed measurement
- OP12Error codeSetting of allowance for speed signal comparison (measurement / control) These values do not reflect the real speed accuracy of the running belt. Accuracy of running belt speed is higher
- OP13Error codeActivating and deactivating motor brake
- OP20Error codeRS232 interface protocol: COM 1 Various ECG and ergospirometry systems support the h/p/cosmos coscom protocol. Individual adaptation of protocol on request. For further information about the h/p/cosmos coscom protocol see www.coscom.org We recommend using the h/p/cosmos coscom v3 protocol as it provides a high standard of safety and functionality and is in compliance with norm EN 62304. All other interface protocols (other than coscom v3) are not validated by h/p/cosmos and not released by h/p/cosmos based on EN 62304 and EN 14971 and must not be used for new installations and configurations of medical devices and medical applications from 21.03.2010. h/p/cosmos para control® and h/p/cosmos para graphics® exclusively work with the h/p/cosmos coscom protocol
- OP34Error codeManual speed calibration (counted increments from the speed sensor for 10 m belt movement) Note. Normally the speed calibration values are set by selecting the correct device type (administrator option number 3)
- OP35Error codeOil interval
- OP37Error codeInterval for service message TSC (time-dependent) for technical safety control E.02 “HELP"
- OP38Error codeService interval (distance-dependent) "E 02" "HELP"
- OP39Error codeElevation: display as set point or true value (This option is only available for treadmills, not for ladder ergometers)
- OP40Error codeSpeed: display as set point or true value
- OP48Error codeMaximum speed during maximum activation of the frequency inverter (applicable for digital RS485 and/or analogue control 0…10 volt of the frequency inverter)
- OP51Error codeError statistics of the digital FI control Note: At each emergency stop the number of timeout errors is increased automatically by at least one numerator because the transmission line to the FI is interrupted by hardware
- OP89Error codeSystem for elevation measurement (option not relevant for treadmills without elevation or ladder ergometers) Note: Normally the correct system for elevation measurement is set by selecting the correct device type (administrator option number 3). Only in very few cases and for special models is this option needed
- OP93Error codeTotal time of operation (h) = standby time including time of use of the motor / running belt Note: It is not allowed to change the total time of operation or the total distance to a value which does not match the real value of the device
- OP94Error codeTotal time of use (h) = time of use of motor / running belt only Note: It is not allowed to change the total time of operation or the total distance of the running machine to a value which does not match the real value of the device
- RS232Error code
- S165Error codeCommunication interruption to external / failsafe
- SPR11Error codeGroup 1 Class B