Skip to content
RemFixitSearch fault code

Error code

h/p/cosmos vakumlu koşu bandı All models code E52

For your safety

This fault is rated critical. No remote repair or do-it-yourself instructions are given; do not use the appliance or try to open or repair it.

If there is a risk to life, first move to a safe place, then call 112. Do not follow remote repair instructions.

Call 112

The emergency numbers here are for Turkey. If you are outside Turkey, call your local emergency number.

All emergency numbers and province details

No approved translation for this record yet; showing the original text.

Meaning

Error of RS485 cable motor control Cable defect or bad contact at the connection MCU/frequency inverter Only applicable for digital control (RS485) of MCU5/frequency inverter

Member details

Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.

View details as a member

Possible causes

= E 52 ! FU flashing § $ % HELP flashing The MCU5 control boards always send a reset message every time the device is switched on. After 10 consecutive time-out failures, the MCU generates the E52 error-message. This is equivalent to a missing connection (e.g. cable defect) from MCU5 to frequency- inverter. N Check RS485 plug at the MCU5 control board. N Check RS485 plug at the frequency inverter. N Check RS485 plug at the opto coupler board. N Contact authorized service engineer

Solution

Solution steps are not shared for faults that may be dangerous.

No do-it-yourself solution is given for this fault. For your safety, call an authorised service.