h/p/cosmos vakumlu koşu bandı All models code OP20
For your safety
This fault is rated critical. No remote repair or do-it-yourself instructions are given; do not use the appliance or try to open or repair it.
If there is a risk to life, first move to a safe place, then call 112. Do not follow remote repair instructions.
Call 112The emergency numbers here are for Turkey. If you are outside Turkey, call your local emergency number.
No approved translation for this record yet; showing the original text.
Meaning
RS232 interface protocol: COM 1 Various ECG and ergospirometry systems support the h/p/cosmos coscom protocol. Individual adaptation of protocol on request. For further information about the h/p/cosmos coscom protocol see www.coscom.org We recommend using the h/p/cosmos coscom v3 protocol as it provides a high standard of safety and functionality and is in compliance with norm EN 62304. All other interface protocols (other than coscom v3) are not validated by h/p/cosmos and not released by h/p/cosmos based on EN 62304 and EN 14971 and must not be used for new installations and configurations of medical devices and medical applications from 21.03.2010. h/p/cosmos para control® and h/p/cosmos para graphics® exclusively work with the h/p/cosmos coscom protocol
Member details
Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.
View details as a memberPossible causes
§ indicates flashing: number of the RS232 interface protocol $ and % reports: OFF = RS232 not active / no protocol / interface deactivated 1 = h/p/cosmos coscom v1, v2, v3 with Baudrate 9600 bps (standard setting COM 1 and COM 2) 2 = JAEGER OXYCON (up to 1995); if available use: h/p/cosmos coscom (= 1). Not to be used after 21.03.2010! 3 = printer protocol (serial printer or converter required) 4 = free 5 = free 6 = free 7 = TM treadmill emulation in km/h if available use: h/p/cosmos coscom (= 1) 8 = TM treadmill emulation in miles per hour if available use: h/p/cosmos coscom (= 1) 9 = free 10 = Loop Back Test (special test plug required, available at h/p/cosmos) 11 = SunTech Tango blood pressure monitor (signal tunnel/loop only) 12 = Remote Control Hardware Terminal MCU 4 (special hardware required) 13 = free 14 = free 17 = free 18 = free 20 = h/p/cosmos coscom v3 with baud rate 115200 bps For advanced h/p/cosmos coscom v3 connections with baud rate 115200, please select OP20=20.
Solution
Solution steps are not shared for faults that may be dangerous.
No do-it-yourself solution is given for this fault. For your safety, call an authorised service.