MAN gemi jeneratörü All models error codes
Codes
- 38Error codeReserve, fuel level in tank 2. Priority 5: Display during stop and driving. Fault: 1. too high; 2. too low; 3. unacceptable; 5. Short circuit to ground; 6. Short circuit to Ubat; 10. Pinout A302: R1 / 14
- 3779Error codeline pressure. Fuel leakage in compensating amount. Engine may stop or lose power. Risk of fire
- 3780Error codeline pressure. High output at idle. Engine may stall due to low line pressure
- 3781Error codepressure limiting valve. Pressure relief valve is open. Fuel pressure is too high. Check valve opening sensitivity
- 3782Error codefuel supply pressure. Possible air ingress into the fuel supply system
- 3783Error codeFFR2: Errors in acceleration reports specified for the noise control unit (NORD). The EDC system limits fuel flow to reduce noise
- 3784Error codeError in Smoke-Identification message. Sent by FFR to select the characteristics of smoke when system exhaust gas recirculation is off
- 3785Error codeparticulate filter PM-Kat (solid catalyst). High or low pressure drop of exhaust gases. If the difference is low, the filter is burnt or missing
- 3786Error codeTemperature of the particle filter. High or low temperature dust filter during a competent recharge. At high temperatures the system capacity decreases
- 3789Error codeSensor drop or comparative exhaust gas pressure sensor.
- 3790Error codeAccuracy exhaust pressure difference. If the exhaust gas pressure is higher than normal when the engine is off, or the pressure drops when the engine speed is two lower than normal, then the sensor is likely to be faulty
- 3792Error codeexhaust gas temperature sensor before additional purification.
- 3793Error codeExhaust gas temperature sensor after aftertreatment (physical parameters). High or low temperatures, faulty wiring or contacts in connectors.
- 3794Error codeExhaust gas temperature sensor after aftertreatment.
- 3795Error codeButterfly valve AGR. The set throttle position does not match the actual situation
- 3796Error codeoutput stage (Highside) EGR 2.
- 3797Error codeOutput stage (Highside) oxygen content in the exhaust gas sensor (oxygen sensor). Checking the output stage for an open or short circuit
- 3800Error codeHighside overflow valve on exhaust turbocharger. Checking the outlet stage for open or short circuit
- 3801Error codeOutput stage (Highside) cut-off valve NT. Checking the output stage for open or short circuit
- 3802Error codeoutput stage (Highside) closed compressed air valve.
- 3803Error codeError sending message CAN1 (FFR / EDC-CAN). CAN message sending error motor. Possibly data channel overloaded. Messages FFR from unit EDC1, EDC2, EDC3 are present
- 3804Error codeError in sending message via CAN1 (FFR/EDC-CAN). Reception of one of the time transmissions/dates of FFR1, FFR2, FFR3 or FFR is not possible
- 3805Error codeError sending message on CAN2 (Master-Slave CAN). Master-Slave Messaging is broken (for V-shaped engine). Possibly data channel overloaded. Slave control unit blocks fuel supply until connection is re-established. Engine only starts when Master unit is at half power
- 3806Error codeCAN2 (Master-Slave CAN). Master-Slave Messaging is broken (for V-shaped engine). Slave controller blocks fuel supply until communication is reestablished. Engine only runs when Master is at half power
- 3807Error codeAn error occurred while sending FFR1 (FFR / EDC-CAN). FFR is transmitting incorrect values on FFR1
- 3808Error codeAn error occurred while sending FFR2 (FFR / EDC-CAN). FFR is transmitting incorrect values on FFR2
- 3809Error codeAn error occurred while sending FFR3 (FFR / EDC-CAN). FFR is transmitting incorrect values on FFR3
- 3810Error codeError in time and date (FFR / EDC-CAN). FFR transmits an invalid value
- 3811Error codeIdentification of exhaust gas temperature before additional treatment.
- 3812Error codeDetermining the exhaust gas temperature after aftertreatment.
- 3813Error codeStarter protection device. The system monitors the starter's operating time. If the starter motor operates for more than 30 seconds, the engine does not start on the display, indicating a fault. The message is displayed until the starter motor cools down
- 3814Error codeControl unit shutdown time. It is not possible to determine the control unit shutdown time. The fault does not affect engine operation and is completely inactive after a software update to version V27
- 3820Error codeTesting the data channel for errors in messages
- 3821Error code
- 3836Error codeDetermination of oxygen sensor amount in exhaust gas values (lambda probe).
- 3837Error codeChecking the amount of oxygen sensor in the exhaust gas (lambda probe).
- 3838Error codeInternal number of oxygen sensor resistance in exhaust gases (oxygen sensor).
- 3839Error codeInternal number of oxygen sensor resistance in exhaust gases (oxygen sensor).
- 3843Error codecoolant temperature.
- 3844Error codeThe temperature of the combustion air before entering the cylinder.
- 3845Error codeAmbient air temperature.
- 3847Error codeTemperature of charge air in pipe after boost intercooler.
- 3851Error codePosition of EGR valve.
- 3852Error codeDefining AGR by temperature. The temperature of the charge air before entering the cylinder is significantly different from the temperature of the discharge air after the intercooler
- 3854Error codeTemperature sensor blockedEDC ?2.
- 3855Error codeOxygen level in exhaust gas sensor (oxygen sensor).
- 3857Error codeSPI Communication oxygen amount in exhaust gas sensor (oxygen sensor). Error check in control units. Malfunction of main control unit with consequences of processing unit
- 3858Error codeTemperature sensor The amount of oxygen in the exhaust gas (lambda probe). Above 800 ° C is considered high temperature. Below 600 ° C is considered low temperature
- 3859Error codeExhaust gas temperature sensor oxygen content calibration value (lambda probe). Calibration value above or below the norm
- 3863Error codeGear Control. High-time injector settings in overrun mode. Control unit restarts in case of failure