MAN gemi jeneratörü All models error codes
Codes
- 70Error code"Parking brake" signal. Priority 2: Fault requiring removal of the service centre. Fault: 8. Wrong signal
- 81Error codeExhaust pressure difference. High or low pressure difference. Checking the rate of change of differential pressure of exhaust gases, checking the cables and connectors
- 94Error codeFuel supply pressure. Low or high fuel pressure. Clogged fuel filter, faulty fuel pump, air in fuel lines. Engine may stall
- 96Error codeReserve, fuel level in tank 1. Priority 5: Display during stop and driving. Fault: 1. too high; 2. too low; 3. unacceptable; 5. Short circuit to ground; 6. Short circuit to Ubat; 10. Pinout A302: R1 / 13
- 639Error codeData Bus T-CAN Higt, serial communication. Priority 1: Requires engine stop. Error: 4. No signal. Pinout A302 M / 1
- 651Error codeBank1, injector 1 (four-cylinder engine cylinder ?1, six-cylinder engine cylinder ?1, eight-cylinder engine cylinder head ?1, ?5 slave cylinder, ten-cylinder engine main ?1, ?6 slave cylinder, twelve-cylinder engine ?1 master cylinder ?12 slave). In case of fault in injector circuit, only one injector is closed, by closing the circuit all injectors of the affected unit are disabled
- 652Error codeBank2 injector 1 (four-cylinder engine cylinder ?3, ?5 cylinder six-cylinder engine, eight-cylinder engine main ?2, ?7 slave cylinder, ten-cylinder engine cylinder head ?5, ?10 slave cylinder, twelve-cylinder engine ?5 master cylinder ?8 slave cylinder). In case of fault in the injector circuit, only one injector is closed, by closing the circuit, all injectors of the affected unit are disabled
- 653Error codeBank1, Injector 2 (four-cylinder engine cylinder ?4, six-cylinder engine cylinder ?3, eight-cylinder engine cylinder head ?3, ?6 slave cylinder, ten-cylinder engine main ?2, ?7 slave cylinder, twelve-cylinder engine ?3 master cylinder ?10 slave). In case of fault in injector circuit, only one injector is closed, by closing the circuit all injectors of the affected unit are disabled
- 654Error codeBank2, Injector 2 (four-cylinder engine cylinder ?2, ?6-cylinder six-cylinder engine, eight-cylinder engine ?4 master cylinder ?8 slave, ten-cylinder engine cylinder ?3 master cylinder ?8 slave, twelve-cylinder engine ?6 master cylinder ?7 slave). In case of fault in the injector circuit, only one injector is closed, by closing the circuit, all injectors of the affected unit are disabled
- 655Error codeBank1, injector 3 (six-cylinder engine cylinder ?4; cylinder ?4 is ten-cylinder engine head, cylinder ?9 is slave, twelve-cylinder engine master ?2, ?11 is slave cylinder). In case of fault in injector circuit, only one injector is closed, circuit is closed, disabling all injectors of the affected unit
- 656Error codeBank2 injector 3 (six-cylinder engine cylinder ?4; cylinder ?2 twelve-cylinder engine head, cylinder ?11 slave). In the event of a fault in the injector circuit, only one injector is closed, closing the circuit disables all injectors of the affected unit
- 767Error codeIncluding transfer of R. Priority 2: Fault requiring removal of the service center. Fault: 5. Pinout A302 M / 6
- 6036Error codeSignal level of liquid in the secondary retarder, during rejection of acceptance or sending of a message. Priority 4: The screen is not displayed, which does not affect the operability. Fault: 8. wrong signal
- 6037Error codeSignal level of liquid in the primary retarder, rejection of acceptance or sending a message. Priority 4: No display affects operability. Fault: 8. wrong signal
- 6038Error codeEEC2 post 2elektronnoy engine management system failure when receiving or sending a message. Priority 4: No display does not affect operability. Fault: 8. wrong signal
- 6039Error codeTransmission fluid level fault signal when receiving or sending messages. Priority 4: No display does not affect operability. Fault: 8. wrong signal
- 6040Error codeSignal for load on rear axle (EBS system), failure to receive or send message. Priority 4: No display does not affect operability. Failure: 8. wrong signal
- 6041Error codeSignal while loading the vehicle (ECAS system), failure while receiving or sending messages. Priority 4: No display does not affect operability. Failure: 8. false signal
- 6042Error codeEngine configuration error signal when receiving or sending message. Priority 4: Not displayed does not affect operability. Error: 8. wrong signal
- 6043Error code"SPN Response (MAN data request)" message for channel I-CAN data error when receiving or sending message. Priority 4: No image does not affect operability. Error: 8th wrong signal
- 6044Error code"SPN Response (MAN data request)" message for channel I-CAN data error when receiving or sending message. Priority 4: Not displayed does not affect operability
- 6045Error codeAfter ECAM1 channel data T-CAN, residual pressure signal fault when receiving or sending message. Priority 4: No display does not affect operability
- 6046Error codeSent by WSK system (hydrotransformer clutch), failure when receiving or sending message. Priority 4: No display does not affect operability. Failure: 8. wrong signal
- 6047Error codePost VDC1 is not accepted due to failure of T-CAN data channel, failure to receive or send message. Priority 4: No display does not affect operability. Error: 8. wrong signal
- 6048Error codeAfter ETC2 channel I-CAN data error while receiving or sending message. Priority 4: No display does not affect operability
- 6050Error codeDM1 ZBR2 sent by channel I-CAN data error. While receiving or sending message. Priority 4: No display does not affect operability
- 6051Error codeDM1 fault memory and pamyatiOBDU (on-board diagnostic device), failure to receive or send messages. Priority 4: No display does not affect operability
- 6052Error codeNotification of chassis number in channel I-CAN data error when receiving or sending message. Priority 4: Not displayed does not affect operability. Error: 8. wrong signal
- 6053Error codeSent by KSM2 (controller for external data exchange) via T-CAN data, failure while receiving or sending message. Priority 4: No display does not affect operability. Failure: 8. wrong signal
- 6054Error codeASS1_A After ECAS (electronic controlled air suspension), failure when receiving or sending messages. Priority 4: No display does not affect operability. Failure: 8th wrong signal
- 6055Error codeASS1_B After ECAS (electronic controlled air suspension), failure when receiving or sending messages. Priority 4: No display does not affect operability. Failure: 8th wrong signal
- 6056Error codeASS1_B After ECAS (electronically controlled air suspension), failure during receiving or sending messages
- 6057Error codeReport on chassis number in channel I-CAN data error when receiving or sending message. Priority 4: No display does not affect operability. Error: 8. wrong signal
- 6058Error codeSignal Aux_Stat Inst2 channel I-CAN data no message about failure during switching, receiving or sending in the data channel. Priority 4: No display, does not affect operability. Error: 8. wrong signal
- 6059Error codeAfter ESP, failure during receiving or sending messages. Priority 4: No display does not affect operability. Error: 8. wrong signal
- 6060Error codeAfter ASS3 ECAS (electronic controlled air suspension), failure when receiving or sending messages. Priority 4: No display does not affect operability. Failure: 8th wrong signal
- 6061Error codeSystem ECAS (electronically controlled air suspension) vehicle weight reporting, failure during message reception or sending. Priority 4: No display does not affect operability. Failure: 8th false signal
- 6062Error codeVehicle weight notification from EBS (electronic controlled brake system), failure when receiving or sending messages. Priority 4: No display does not affect operability. Failure: 8. wrong signal
- 6250Error codeNo buffer CAN data communication channel (reserved by the manufacturer for ZBR or ZBRO). Priority 4: No display does not affect operability. Error: 4. No signal
- 6251Error codeMessages on the dannyhCAN channel were not processed (manufacturer reserves for ZBR or ZBRO). Priority 4: No image affects operability. Error: 4. No signal
- 6280Error codeROM error check (program code) (reserve for manufacturer ZBR or ZBRO). Priority 2: Error requiring removal of service center. Error: 3. Unacceptable
- 6281Error codeROM check error (EOL option (factory programming)) (manufacturer reserve for ZBR or ZBRO). Priority 2: Error requiring removal of service center. Error: 3. Unacceptable
- 6302Error codeK-cable KWP2000 (a protocol for diagnostics using a PC), Serial communication. Priority 2: Malfunction requiring removal of the service center. Pinout A302 M / 10
- 6303Error codeT-CAN Masse, serial communication. Pinout A302 M / 9
- 6304Error codeThe signal indicating the temporary fault is data channel T-CAN, serial communication. Priority 4: No display, does not affect the operability. Fault: 4. No signal
- 6305Error codeTemporary fault signal I-CAN data channel serial communication. Priority 4: No display, does not affect operability. Fault: 4. No signal
- 8010Error codeNotification that the pressure has fallen below the acceptable level vECAM (electronically controlled air suspension). Priority 1: Requires engine shutdown or Priority 2: Fault requiring service centre removal. Fault: 2. Too low
- 8104Error codeResidual pressure in circuit 5 (input circuit) in the ECAM system (electronic controlled air suspension). Priority 1: Requires engine shutdown. Fault: 1. too high; 2. too low; 4. No signal; 6. Short circuit to Ubat. Pinout A302 M / 15
- in2Error codeConical ring in 2/2 Rotocap, complete Spring, inner Spring, outer Valve spindles, inlet Valve spindles, exhaust