Fanuc All models error codes
Codes
- 6Error codeSign “ - ” input error (Sign “ - ” was input after an address with which it cannot be used. Or two or more “ - ” signs were input.) Modify the program
- 7Error codeDecimal point “.” input error (A decimal point was input after an address with which it can not be used. Or two decimal points were input.) Modify the program
- 80Error codeM series;In the automatic tool length measurement function (G37), the measurement position reach signal (XAE, YAE,or ZAE) is not turned on within an area specified in parameter 6254 (value ε).This is due to a setting or operator error
- 85Error codeWhen entering data in the memory by using Reader / Puncher interface,an overrun, parity or framing error was generated. The number of bits of input data or setting of baud rate or specification No. of I/O unit is incorrect
- 86Error codeWhen entering data in the memory by using Reader / Puncher interface,the ready signal (DR) of reader / puncher was off.Power supply of I/O unit is off or cable is not connected or a P.C.B. is defective
- 87Error codeWhen entering data in the memory by using Reader / Puncher interface,though the read terminate command is specified, input is not interrupted after 10 characters read. I/O unit or P.C.B. is defective
- 88Error codeFile data transfer over the OSI-Ethernet was terminated as a result of a transfer error
- 89Error codeFile data transfer over the OSI-Ethernet was terminated as a result of a transfer error
- 97Error codeP type cannot be directed when the program is restarted.(After power ON, after emergency stop or P/S alarm 94 to 97 were reset, no automatic operation is performed).Perform automatic operation
- 5115Error codeThere is an error in the specification of the rank. No knot is specified. The knot specification has an error. The number of axes exceeds the limits. Other program errors
- 5116Error codeThere is a program error in a block under look-ahead control. Monotone increasing of knots is not observed. In NURBS interpolation mode, a mode that cannot be used together is specified
- 5122Error codeA spiral interpolation or conical interpolation command has an error. Specifically, this error is caused by one of the following;1) L = 0 is specified.;2) Q = 0 is specified.;3) R/, R/, C is specified.;4) Zero is specified as height increment.;5) Three or more axes are specified as the height axes.;6) A height increment is specified when there are two height axes.;7) Conical interpolation is specified when the helical interpolation function is not selected.;8) Q 0 is specified when radius difference 0.;9) Q 0 is specified when radius difference 0.;10) A height increment is specified when no height axis is specified
- 5135Error codeFSSB has entered error mode
- 5137Error codeFSSB detected a configuration error
- 5139Error codeServo initialization did not terminate normally. The optical cable may be defective, or there may be an error in connection to the amplifier or another module. Check the optical cable and the connection status
- 5195Error codeWhen the touch sensor with a single contact signal input is used in the direct input B function for tool offset measurement values, the stored pulse direction is not constant. One of the following conditions exists;· The stop state exists in offset write mode.;· Servo off state;· The direction varies.;· Movement takes place simultaneously along two axes
- 5196Error codeDetach operation was performed in HPCC mode. (If detach operation is performed in HPCC mode, this alarm is issued after the currently executed block terminates.)
- 5212Error codeThere is a parameter setting error. Check that 4 is set as the I/O channel
- 5213Error codeThe memory card cannot be used. Check the memory card. (Check whether the memory card is write-protected or defective.)
- 5218Error codeThere is an inclination compensation parameter setting error. Cause;1. The number of pitch error compensation points between the negative (-) end and positive (+) end exceeds 128.;2. The relationship in magnitude among the inclination compensation point numbers is incorrect.;3. An inclination compensation point is not located between the negative (-) end and positive (+) end of the pitch error compensation points.;4. The amount of compensation per compensation point is too large or too small. Correct the parameter
- 5222Error codeThe SRAM correctable error cannot be corrected. Cause: A memory problem occurred during memory initialization. Action: Replace the master printed circuit board (SRAM module)
- 5227Error codeA specified file is not found during communication with the built-in Handy File
- 5231Error codeThe number of files exceeds the limit during communication with the built-in Handy File
- 5235Error codeA communication error occurred during communication with the built-in Handy File
- 5237Error codeA floppy disk in the built-in Handy File cannot be read from. The floppy disk may be defective, or the head may be dirty. Alternatively, the Handy File is defective
- 5238Error codeA floppy disk in the built-in Handy File cannot be written to. The floppy disk may be defective, or the head may be dirty. Alternatively, the Handy File is defective
- 5242Error codeThe axis number of the synchronous master axis or slave axis is incorrect. (This alarm is issued when flexible synchronization is turned on.) Alternatively, the axis number of the slave axis is smaller than that of the master axis
- 5243Error codeThe gear ratio is not set correctly. (This alarm is issued when flexible synchronization is turned on.)
- 5300Error codeAfter the inch/metric automatic conversion function (OIM: Bit 0 of parameter No. 5006) for tool offset data is enabled or disabled, all the tool offset data must be reset. This message reminds the operator to reset the data. If this alarm is issued, reset all the tool offset data. Operating the machine without resetting the data will result in a malfunction
- 5303Error codeA touch panel error occurred. Cause;1. The touch panel is kept pressed.;2. The touch panel was pressed when power was turned on. Remove the above causes, and turn on the power again
- 5311Error codeA connection related to FSSB is illegal. This alarm is issued when either of the following is found;1. Two axes having adjacent servo axis numbers (parameter No. 1023), odd number and even number, are assigned to amplifiers to which different FSSB systems are connected.;2. The system does not satisfy the requirements for performing HRV control, and use of two pulse modules connected to different FSSB systems having different FSSB current control cycles is specified
- 5321Error codeThe straightness compensation value has exceeded the maximum value of 32767.After this alarm is issued, make a manual reference position return
- 5400Error codeAn axis specified for spline interpolation or smooth interpolation is incorrect. If an axis that is not the spline axis is specified in spline interpolation mode, this alarm is issued. The spline axis is the axis specified in a block containing G06.1 or the next block. For smooth interpolation, the axis specified in G5.1Q2 is incorrect
- 5402Error codeA movement is made along an axis that is not the spline interpolation axis. For example, in three-dimensional tool compensation mode using an offset vector of which components are the X-, Y-, and Z-axes, when two-axis spline interpolation is performed with the two spline axes set to the X- and Y-axes, a movement along the Z-axis occurs, resulting in this alarm
- 5452Error codeA G code that cannot be specified is found. (5-axis mode) This alarm is issued when;1) Three-dimensional cutter compensation (side-face offset and leading- edge offset) is applied during cutter compensation, or cutter compensation is applied during three-dimensional cutter compensation (side-face offset and leading-edge offset).;2) A leading-edge offset of three-dimensional cutter compensation is applied during side-face offsetting of three-dimensional cutter compensation, or a side-face offset of three-dimensional cutter compensation is applied during leading-edge offsetting of three-dimensional cutter compensation.;3) Tool axis direction tool length compensation is applied during tool length compensation, or tool length compensation is applied during tool axis direction tool length compensation.;4) Tool center point control is provided during tool length compensation, or tool length compensation is applied during tool center point control.;5) Tool center point control is provided during tool axis direction tool length compensation, or tool axis direction tool length compensation is applied during tool center point control.;If this alarm is issued, cancel the relevant mode, then s
- 5453Error codeWhen bit 2 of parameter No. 5400 is set to 1, and a reset does not cancel G68, this alarm is issued at the time of program restart. To release this alarm, press RESET and CAN. Once this operation is performed, the alarm will not be issued at the next restart
- EN6100Error codeIEC801-4
- G54Error codeG59 iş parçası koordinat sistemi değerleri hatalı veya eksik
- I0051Error codeCounter Error status
- IC693AError codeGE Fanuc Automation N.A., Inc. - Asia Pacific Operations No. 1 Teban Gardens Crescent Jurong - Singapore 608919 Phone: (65) 566-9902 or (65) 566-4918 Fax: 011 (65) 567-1856 or 011 (65) 566-7703
- Q0051Error codeClear error (all counters)
- R0106Error codeStart address + 5
- RSError code232 veya Ethernet üzerinden veri transferinde hata
- S0001Error codefst scn _
- S0002Error codelst scn _
- S0009Error codesy full _
- S0010Error codeio full _
- SA0003Error codeapl flt _
- SB0009Error codeno prog _
- SB0014Error codestor er _