Yaskawa All models error codes
Codes
- CEError codeMEMOBUS/Modbus İletişim Hatası ( devamı >> )
- CFError codeKontrol Hatası ( devamı >> )
- CF1Error codeFeedback Option Module Communications Error(Reception error)
- CF2Error codeFeedback Option Module Communications Error(Timer stop)
- CPF00Error codeDigital Operator Transmission Error 1
- CPF01Error codeDigital Operator Transmission Error 2
- CPF02Error codeSürücünün kontrol devresinde bir sorun var
- CPF03Error codeControl Board Connection Error
- CPF06Error codeEEPROM Memory Data Error
- CPF07Error codeTerminal Board Connection Error
- CPF20Error codeControl Circuit Error
- CPF22Error codeHybrid IC Error
- CPF23Error codeControl Board Connection Error
- CPF24Error codeDrive Unit Signal Fault
- CPF25Error codeKontrol panosuna ba÷lı terminal panosu yoktur
- CPF46Error codeTerminal Board Error
- d00Error codePosition Error Overflow(Position error exceeded the value set in the excessive position error alarm level (Pn520).)
- d01Error codePosition Error Overflow Alarm at Servo ON
- d02Error codePosition Error Overflow Alarm by Speed Limit at Servo ON
- d3-01Error coded3-01 to d3-04 allow programming of three prohibited frequency reference points for eliminating problems with resonant vibration of the motor / machine. This feature does not eliminate the selected frequency values, but accelerates and decelerates the motor through the prohibited bandwidth. The parameters must be according to the rule d3-01 ≥ d3-02 ≥ d3-03
- d10Error codeMotor-load Position Error Overflow
- ded20Error codeThe torque reference exceeded 20% during Auto-Tuning
- ded80Error codeThe results from Auto-Tuning the no-load current exceeded 80%
- ded110Error codeExceeded 110% of the rated output current of the drive while operating at low speeds
- E1Error codeV/f Pattern for Motor 1
- E1-01Error codeInput Voltage
- E1-04Error codeLED Operator Display Cause The following simultaneous contradictory settings: C6-05 is greater than 6 and C6-04 is greater than C6-03 (carrier frequency lower limit is greater than the upper limit). If C6-05 is less than or equal to 6, the drive operates at C6-03. Upper and lower limits between C6-0
- E1-05Error codeMaximum Voltage
- E1-06Error codeBase voltage
- E1-08Error codeMid Output Frequency Voltage
- E1-09Error codePhase wiring between the drive and motor is incorrect. The forward direction for the motor is set up incorrectly. The motor is running at almost 0 Hz and the Speed Search estimated the speed to be in the opposite direction.
- E1-12Error codeMid Output Frequency Voltage 2
- E1-13Error codeBase Voltage
- E2Error codeMotor 1 Parameters .............................................................................................................150
- E2-01ParameterCurrent suppression prevents the drive from accelerating. Load is too heavy. Frequency reference is too low. Load is too heavy. Acceleration time has been set too long. Motor characteristics and drive parameter settings are incompatible with one another. Incorrect frequency reference setting. The St
- E2-02Error codeSets the motor rated slip in Hertz. Automatically set during rotational Auto-Tuning
- E2-03Error codeSets the magnetizing current of the motor in Ampere. Automatically set during rotational Auto-Tuning
- E2-05Error codeSets the phase-to-phase motor resistance in ohms. Automatically set during Auto-Tuning
- E2-06Error codeSets the voltage drop due to motor leakage inductance as a percentage of motor rated voltage. Automatically set during Auto-Tuning
- E2-08Error codeSets the motor iron saturation coefficient at 75% of magnetic flux. Automatically set during Auto-Tuning
- E2-09Error codeSets the motor mechanical loss as a percentage of motor rated power (kW). Adjust in the following circumstances: When there is a large amount of torque loss due to motor bearing friction. When there is a large amount of torque loss
- E2-10Error codeSets the motor iron loss in watts (W)
- E2-12Error codeSet to the motor iron saturation coefficient at 130% of magnetic flux. Automatically set during rotational Auto-Tuning
- E3Error codeV/f Characteristics for Motor 2 .............................................................................................152
- E3-04Error codeThese parameters set the V/f pattern for motor 2. To set linear V/f characteristics, set the same values for E3-07 and E3-09. In this case, the setting for E3-08 will be disregarded. Ensure that the four frequencies are set according to these rules or oPE10 fault will occur: E3-04 ≥ E3-06 > E3-07 > E3-09 VACrms Out (V) E3-05 E3-12 E3-13 E3-08 E3-10 E3-09 E3-07 E3-06 E3-11 E3-04 Frequency (Hz)
- E4Error codeMotor 2 Parameters .............................................................................................................153
- E4-01Error codeSets the motor 2 nameplate full load current in amperes (A). This value is automatically set during Auto-Tuning
- E4-02Error codeSets the motor 2 rated slip in Hz. Automatically set during Auto-Tuning
- E4-03Error codeSets the magnetizing current of motor 2 in Ampere. Automatically set during Rotational Auto-Tuning
- E4-04Error codeSets the number of poles of motor 2. This value is automatically set during Auto-Tuning