Codes
- P1-07Error codeAsynchronous motor rotor resistance
- P1-08Error codeLeakage inductance of asynchronous motor
- P1-09Error codeMutual inductance of asynchronous motor
- P1-10Error codeNo load current of asynchronous motor
- P1-35Error codeSelf learning of motor parameters
- P2-00Error codeInput terminal X1 function selection
- P2-59Error codeAI mode switch
- P3Error code
- P3-01Error codeY1 output function selection
- P3-13Error codeAO1 output selection
- P4-00Error codeStart mode
- P4-03Error codeStarting DC brake current/ pre-excitation current percentage
- P4-06Error codeSpeed tracking mode (Only valid for asynchronous motors)
- P4-10Error codeSpeed tracking closed loop current
- P4-25Error codePercentage of DC braking current during stop
- P5-02Error codeMultipoint VF voltage point V1
- P5-04Error codeMultipoint VF voltage point V2
- P5-05Error codeMultipoint VF frequency point F3
- P5-06Error codeMultipoint VF voltage point V3
- P5-09Error codeThe voltage source of VF separation
- P5-10Error codeVoltage source digital setting of VF separation
- P5-11Error codeVoltage acceleration time of VF separation
- P5-12Error codeVoltage deceleration time of VF separation
- P5-13Error codeVF separated stop mode selection
- P5-19Error codeVF over current stall action current
- P5-20Error codeVF over current stall suppression enable
- P5-21Error codeVF over current stall suppression gain
- P5-22Error codeVF over current stall action current compensation coefficient
- P5-23Error codeVF over voltage stall action voltage
- P5-24Error codeVF over voltage stall suppression enable
- P5-25Error codeWF over voltage stall suppression frequency gain
- P5-26Error codeVF over voltage stall suppression voltage gain
- P5-27Error codeVF over voltage stall maximum rise frequency limit
- P5-34Error codePID stop reference voltage (3742 and above versions support)
- P6-10Error codeSpeed control (drive) torque upper limit source
- P7Error code20: Wave by wave current limiting fault 21: Magnetic pole position detection failed 23: Brake resistance short circuit 26: SVC stall fault 43: External fault 44: Communication fault 45: EEPROM read / write fault 46: Operation time arrival 47: Power on time arrival 48: User defined fault 1 49: User defined fault 2 50: PID feedback loss during operation 51: Switch motor during operation 52: Speed feedback deviation too large 53: Motor over speed 54: Motor over temperature fault 56: Power on lock time arrival
- P7-00Error codeThird (last) time fault type
- P7-01Error codeSecond time fault type
- P7-02Error codeFirst time fault type
- P7-03Error codeThird (last) time fault frequency
- P7-04Error codeThird (last) time fault current
- P7-05Error codeThird (last) time fault bus voltage
- P7-06Error codeThird (last) time fault input terminal status
- P7-07Error codeThird (last) time fault output terminal status
- P7-08Error codeThird (last) time fault VFD status
- P7-09Error codeThird (last) time fault power on time
- P7-10Error codeThird (last) time fault operation time
- P7-11Error codeLocation information of the third (last) time fault
- P7-13Error codeSecond time fault frequency
- P7-14Error codeSecond time fault current