- a02bError codeTH ERROR DEFIB CONFIG (Conflicting defib type. Cold boot if test bit set; otherwise, disable biphasic; param = test-bit setting.) _ _ _
- a02cError codeTH ERROR DUMP LINE FAIL (One of dump lines failed; param = test ID.) _ _ _ _
- a02dError codeTH ERROR WRONG DEFIB TYPE (Wrong Defib. type for software.) _ _ _ _
- a02eError codeTH ERROR ADC READ (ADC read failure when getting cap charge.) _ _ _
- A03Error codePower PCB
- A04Error codeTherapy PCB-Edmark Devices
- A05Error codeInterface PCB
- A06Error codeOEM PCB Assembly
- A07Error codeContact PCB
- A08Error codeBacklight PCB
- a10bError codeDE ERROR CHG TIME (Takes too long to reach charge.) _ _ _
- a10cError codeDE ERROR CHG ENABLE (CHG EN1 is stuck high.) _ _ _ _
- a10dError codeDE ERROR DUMP ENERGY (Defib HW error.) _ _ _
- a10eError codeDE ERROR RCV (Defib HW error.) _ _
- a11aError codeDE ERROR TEST CPU (Defib HW error.) _ _ _
- a11dError codeDE ERROR XFER TIMEOUT (Defib HW error.) _ _ _
- a11eError codeDE ERROR BUTTONS UP (Defib HW error.) _ _ _
- a11fError codeDE ERROR SYNC INTERRUPT (Defib HW error.) _ _ _
- a020Error codeTH ERROR PACER DISABLE (Pacer disabled; cannot communicate with processor.) _ _ _
- a021Error codeTH ERROR CAP CHARGE FAIL (Cap. stays zero while charging. No charge; param = defib setting.) _ _ _ _
- a022Error codeTH ERROR CORRUPT ENERGY SELECT (Energy select corrupt; param = main energy selection.) _ _ _ _
- a023Error codeTH ERROR XFER ENABLE ON (Defib transfer-enable line high unexpected. Defib transfer-enable line was not off during startup.) _ _ _ _
- a024Error codeTH ERROR VCAP2 SATURATED (VCAP2 reading full scale all the time. Reading not processed.) _ _ _
- a026Error codeTH ERROR ENERGY RESIDUE (There is still energy on the cap.) _ _ _
- a027Error codeTH ERROR PA RATE CORRUPT (Pacing rate storage corrupted; param: high-16 = rate selected, low-16 = actual rate.) _ _ _ _
- a028Error codeTH ERROR CAL ENERGY FAIL (Calibrated voltage is out of range; param: high-16 = table index, low-16 = voltage count.) _ _ _ _
- a029Error codeTH ERROR BTE FAIL (Error condition with BTE board; param: high-16 bits = fault type, low-16 bits = cedar state.) _ _ _
- a101Error codeDE ERROR LONG WDT (Long watchdog test failed or watchdog did not reset in time.) _ _ _
- a102Error codeDE ERROR SHORT WDT (Short watchdog test failed.) _ _ _
- a103Error codeDE ERROR SCI RCV (Serial port receiver error.) _ _ _
- a104Error codeDE ERROR XFER KEY (Defib HW error.) _ _ _
- a106Error codeDE ERROR ENERGY OUT OF BOUND (VCAP-1 over/under charge.) _ _ _ _ _
- a107Error codeDE ERROR HP ENG SELECT (Cannot determine the rotary setting.) _ _ _ _
- a109Error codeDE ERROR CAL CRC (Calibration Table CRC error.) _ _ _
- a111Error codeDE ERROR ENERGY NOT ZERO (Unexpected energy while biphasic is in high-pot test.) _ _ _ _
- a112Error codeDE ERROR TEST XFER ENABLE (Problem with transfer; turn on at main.) _ _ _ _
- a113Error codeDE ERROR TEST XFER ENGAGE (Error reading the transfer engage feedback.) _ _ _ _
- a114Error codeDE ERROR TEST DUMP RELAY (Biphasic error.) _ _ _ _
- a115Error codeDE ERROR TEST ADC (Defib HW error.) _ _ _
- a116Error codeDE ERROR TEST DAC (Defib HW error.) _ _ _
- a117Error codeDE ERROR TEST HARDWARE (Defib HW error.) _ _ _
- a118Error codeDE ERROR TEST RAM (Defib HW error.) _ _ _
- a119Error codeDE ERROR TEST ROM (Defib HW error.) _ _ _
- a120Error codeDE ERROR SELF TEST INCOMPLETE (Defib HW error.) _ _ _ _
- a123Error codeDE ERROR CAL RCV CRC (CRC failed for new calibration data.) _ _ _ _
- a124Error codeDE ERROR CAL NVM CRC (Cannot write energy table to EEPROM.) _ _ _ _
- a125Error codeDE ERROR DAC WRITE (Byte could not be written to the DAC through the SPI interface.) _ _ _
- a126Error codeDE ERROR ADC READ (Cannot read from ADC.) _ _ _
- a127Error codeDE ERROR TEST MODE (Must be idle to switch to test mode.) _ _ _
- a129Error codeDE ERROR XFER CABLE (Defib HW error.) _ _ _