Olivetti fotokopi makinesi All models error codes
Codes
- U1Error codeDetail
- U2Error codeDetail
- U6Error codeDetail
- U7Error codeDetail
- U009XError codeA page reception error occurred in G3 mode (refer to 1-4-35 U009XX error code table)
- U010XError codeTransmission in G3 mode was interrupted by a signal error (refer to 1-4-36 U010XX error code table)
- U011XError codeReception in G3 mode was interrupted by a signal error (refer to 1-4-37 U011XX error code table)
- U017XError codeA communication error occurred before starting T.30 protocol during transmission in V.34 mode (refer to 1-4-38 U017XX error code table)
- U018XError codeA communication error occurred before starting T.30 protocol during reception in V.34 mode (refer to 1-4-38 U018XX error code table)
- U044XError codeCommunication was interrupted because of an encryption key error during encrypted transmission (refer to 1-4-38 U044XX error code table)
- U0090Error codeAn RTN or PIN signal was transmitted because of a page reception error
- U0091Error codeA page reception error remained after retry of transmission in the ECM mode
- U0109Error codeDuring transmission in V.34 mode, communication was interrupted because of an impos- sible combination of the symbol speed and communication speed
- U0110Error codeFunction of the unit (excl. communication mode select) differs from that indicated by an NSS signal
- U0116Error codeReception was aborted due to a modem malfunction during message reception
- U0119Error codeCommunication was interrupted because an error occurred during an image data recep- tion sequence in the V.34 mode
- U0140Error codeAn invalid one-touch key was specified during communication
- U0150Error codeA communication error occurred when calling in V.8 mode
- U0160Error codeA communication error occurred when called in V.8 mode
- U0170Error codeA communication error occurred in phase 2 (line probing)
- U0172Error codeA communication error occurred in phase 4 (modem parameter exchange)
- U0180Error codeA communication error occurred in phase 2 (line probing)
- U0181Error codeA communication error occurred in phase 3 (primary channel equivalent device training)
- U0182Error codeA communication error occurred in phase 4 (modem parameter exchange)
- U250ParameterSetting the maintenance cycle Description Displays, clears and changes the maintenance cycle. Purpose To check and change the maintenance cycle. Method 1. Press the start key. The currently set maintenance cycle is displayed. Setting 1. Select [M.CNT A] using the cursor up/down keys. 2. Change the setting using the cursor left/right keys or numeric keys. Description Setting range Initial setting Maintenance cycle 0 to 9999999 100000 3. Press the start key. The value is set. Clearing 1. Select [CLEAR] using the cursor up/down keys. 2. Press the start key. The count is cleared. Completion Press the stop key. The screen for selecting a maintenance item No. is displayed
- U345ParameterSetting the value for maintenance due indication Description Sets when to display a message notifying that the time for maintenance is about to be reached, by setting the number of copies that can be made before the current maintenance cycle ends. When the difference between the number of copies of the maintenance cycle and that of the maintenance count reaches the set value, the message is displayed. Purpose To change the time for maintenance due indication. Setting 1. Press the start key. 2. Select [COUNT] using the cursor up/down keys. 3. Change the setting using the cursor left/right keys. Description Setting range Initial setting Time for maintenance due indication 0 to 9999 0 (Remaining number of copies that can be made before the current maintenance cycle ends) 4. Press the start key. The value is set. Clearing 1. Select [CLEAR] using the cursor up/down keys. 2. Press the start key. The value is cleared. Completion Press the stop key. The screen for selecting a maintenance item No. is displayed
- U411Error codeError Codes Codes Description 01 Black band detection error (scanner leading edge registration) 02 Black band detection error (scanner center line) 03 Black band detection error (scanner main scanning direction magnification) 04 Black band is not detected (scanner leading edge registration) 05 Black band is not detected (scanner center line) 06 Black band is not detected (scanner main scanning direction magnification) 07 Black band is not detected (scanner auxiliary scanning direction magnification) 08 Black band is not detected (DP main scanning direction magnification far end) 09 Black band is not detected (DP main scanning direction magnification near end) 0a Black band is not detected (DP auxiliary scanning direction magnification leading edge) 0b Black band is not detected (DP auxiliary scanning direction magnification leading edge original check) 0c Black band is not detected (DP auxiliary scanning direction trailing edge) 0d Black band is not detected (DP auxiliary scanning direction trailing edge 2) 0e DMA time out 0f Auxiliary scanning direction magnification error 10 Auxiliary scanning direction leading edge detection error 11 Auxiliary scanning direction trailing edge de
- U600Error codeInitializing all data Description Initializes software switches and all data in the backup data on the FAX control PWB, according to the destination and OEM. Executes the check of the file system, when abnormality of the file system is detected, initializes the file system, communication past record and register setting contents. Purpose To initialize the FAX control PWB. Method 1. Press the start key. 2. Select [Execute]. The screen for entering the destination code and OEM code is displayed. 3. Select [Country Code] and enter a destination code using the numeric keys (refer to the des- tination code list on following for the destination code). 4. Press the start key. There is no operation necessary on this screen. The destination code and the OEM code are displayed with the values currently set. 5. Press the start key. Data initialization starts. To cancel data initialization, press the stop key. 6. After data initialization, the entered destination, OEM codes and ROM version are displayed. A ROM version displays three kinds, application, boot, and IPL. Destination code list Code Destination Code Destination 000 Japan 253 CTR21 (European nations) 009 Australia Italy 038 China Ger
- U601Error codeInitializing permanent data Description Initializes software switches on the FAX control PWB according to the destination and OEM. Purpose To initialize the FAX control PWB without changing user registration data. Method 1. Press the start key. 2. Select [Execute]. The screen for entering the destination code and OEM code is displayed. 3. Select [Country Code] and enter a destination code using the numeric keys (refer to the des- tination code list on page 1-3-22 for the destination code). 4. Press the start key. There is no operation necessary on this screen. The destination code and the OEM code are displayed with the values currently set. 5. Press the start key. Data initialization starts. To cancel data initialization, press the back key. 6. After data initialization, the entered destination, OEM codes and ROM version are displayed. A ROM version displays three kinds, application, boot, and IPL
- U630Error codeSetting communication control 1 Description Makes settings for fax transmission regarding the communication. Method 1. Press the start key. 2. Select the item to be set using the cursor up/down keys. Display Description TX SPEED Sets the communication starting speed. RX SPEED Sets the reception speed. TX ECHO Sets the waiting period to prevent echo problems at the sender. RX ECHO Sets the waiting period to prevent echo problems at the receiver. Setting the communication starting speed Sets the initial communication speed when starting transmission. When the destination unit has V.34 capability, V.34 is selected for transmission, regardless of this setting. 1. Select the setting using the cursor up/down keys. Display Description 14400bps/V17 V.17, 14400 bps 9600bps/V29 V.17, 9600 bps 4800bps/V27ter V.27ter, 4800 bps 2400bps/V27ter V.27ter, 2400 bps * : Initial setting: 14400bps/V17 2. Press the start key. The setting is set
- U631Error codeSetting communication control 2 Description Makes settings regarding fax transmission. Method 1. Press the start key. 2. Select the item to be set using the cursor up/down keys. Display Description ECM TX Sets ECM transmission. ECM RX Sets ECM reception. CED FREQ. Sets the frequency of the CED signal. Setting ECM transmission To be set to OFF when reduction of transmission costs is of higher priority than image quality. This should not be set to OFF when connecting to the IP (Internet Protocol) telephone line. 1. Select the setting using the cursor up/down keys. Display Description ON ECM transmission is enabled. OFF ECM transmission is disabled. * : Initial setting: ON 2. Press the start key. The setting is set. Setting ECM reception To be set to OFF when reduction of transmission costs is of higher priority than image quality. This should not be set to OFF when connecting to the IP (Internet Protocol) telephone line. 1. Select the setting using the cursor up/down keys. Display Description ON ECM reception is enabled. OFF ECM reception is disabled. * : Initial setting: ON 2. Press the start key. The setting is set. Setting the frequency of the CED signal Sets the frequency of the
- U632Error codeSetting communication control 3 Description Makes settings for fax transmission regarding the communication. Method 1. Press the start key. 2. Select the item to be set using the cursor up/down keys. Display Description DIS 4BYTE Sets the DIS signal to 4 bytes. SHORT PRTCL TX Sets the short protocol transmission. SHORT PRTCL RX Sets the reception of short protocol transmission. NUM OF CNG(F/T) Sets the CNG detection times in the fax/telephone auto select mode. Setting the DIS signal to 4 bytes Sets if bit 33 and later bits of the DIS/DTC signal are sent. 1. Select the setting using the cursor up/down keys. Display Description ON Bit 33 and later bits of the DIS/DTC signal are not sent. OFF Bit 33 and later bits of the DIS/DTC signal are sent. * : Initial setting: OFF 2. Press the start key. The setting is set. Setting the short protocol transmission Sets if short protocol transmission is performed. 1. Select the setting using the cursor up/down keys. Display Description ON Short protocol transmission is performed. OFF Short protocol transmission is not performed. * : Initial setting: ON 2. Press the start key. The setting is set. Setting the reception of a short protocol transmissi
- U633Error codeSetting communication control 4 Description Makes settings for fax transmission regarding the communication. Purpose To reduce transmission errors when a low quality line is used. Method 1. Press the start key. 2. Select the item to be set using the cursor up/down keys. Display Description V.34 Enables or disables V.34 communication. V.34-3429Hz Sets the V.34 symbol speed (3429 Hz). DIS 2RES Sets the number of times of DIS signal reception. RTN CHECK Sets the reference for RTN signal output. Enabling/disabling V.34 communication Sets whether V.34 communication is enabled/disabled for transmission and reception. 1. Select the setting using the cursor up/down keys. Display Description ON V.34 communication is enabled for both transmission and reception. TX V.34 communication is enabled for transmission only. RX V.34 communication is enabled for reception only. OFF V.34 communication is disabled for both transmission and reception. * : Initial setting: ON 2. Press the start key. The setting is set
- U634Error codeSetting communication control 5 Description Sets the maximum number of error bytes judged acceptable when receiving a TCF signal. Used as a measure to ease transmission conditions if transmission errors occur. Setting 1. Press the start key. 2. Change the setting using the cursor left/right keys or numeric keys. Description Setting range Initial setting Number of allowed error bytes when detecting TCF 0 to 255 0 3. Press the start key. The value is set. Completion Press the stop key. The screen for selecting a maintenance item No. is displayed
- U640ParameterSetting communication time 1 Description Sets the detection time when one-shot detection is selected for remote switching. (This setting item will be displayed, but the setting made is ineffective.) Sets the detection time when continuous detection is selected for remote switching. (This setting item will be displayed, but the setting made is ineffective.) Method 1. Press the start key. 2. Select the item to be set using the cursor up/down keys. Display Description TIME (ONE) Sets the one-shot detection time for remote switching. TIME (CONT) Sets the continuous detection time for remote switching. Setting the one-shot detection time for remote switching 1. Change the setting using the cursor left/right keys. Description Setting range Initial setting One-shot detection time for remote switching 0 to 255 7 2. Press the start key. The value is set. Setting the continuous detection time for remote switching 1. Change the setting using the cursor left/right keys. Description Setting range Initial setting Continuous detection time for remote switching 0 to 255 80 2. Press the start key. The value is set. Completion Press the stop key. The screen for selecting a maintenance item No. is di
- U641ParameterSetting communication time 2 Description Sets the time-out time for fax transmission. Purpose To improve transmission performance for international communications mainly. Method 1. Press the start key. 2. Select the item to be set using the cursor up/down keys. Display Description T0 TIME OUT Sets the T0 time-out time. T1 TIME OUT Sets the T1 time-out time. T2 TIME OUT Sets the T2 time-out time. Ta TIME OUT Sets the Ta time-out time. Tb1 TIME OUT Sets the Tb1 time-out time. Tb2 TIME OUT Sets the Tb2 time-out time. Tc TIME OUT Sets the Tc time-out time. Td TIME OUT Sets the Td time-out time. Setting the T0 time-out time Sets the time before detecting a CED or DIS signal after a dialing signal is sent. Depending on the quality of the exchange, or when the auto select function is selected at the destination unit, a line can be disconnected. Change the setting to prevent this problem. 1. Change the setting using the cursor left/right keys. Description Setting range Initial setting T0 time-out time 30 to 90 s 56 2. Press the start key. The value is set. Setting the T1 time-out time Sets the time before receiving the correct signal after call reception. No change is necessary for this ma
- U660Error codeSetting the NCU Description Makes setting regarding the network control unit (NCU). Purpose To be set when installing the facsimile kit. Method 1. Press the start key. 2. Select the item to be set using the cursor up/down keys. Display Description EXCHANGE Sets the connection to PBX/PSTN. DIAL TONE Sets PSTN dial tone detection. BUSY TONE Sets busy tone detection. PBX SETTING Setting for a PBX. DC LOOP Sets the loop current detection before dialing. Setting the connection to PBX/PSTN Selects if a fax is to be connected to either a PBX or public switched telephone network. 1. Select the setting using the cursor up/down keys. Display Description PSTN Connected to the public switched telephone network. PBX Connected to a PBX. * : Initial setting: PSTN 2. Press the start key. The setting is set. Setting PSTN dial tone detection Selects if the dial tone is detected to check the telephone is off the hook when a fax is connected to a public switched telephone network. 1. Select the setting using the cursor up/down keys. Display Description ON Detects the dial tone. OFF Does not detect the dial tone. * : Initial setting: ON 2. Press the start key. The setting is set
- U670Error codeOutputting lists Description Outputs a list of data regarding fax transmissions. Printing a list is disabled either when a job is remaining in the buffer or when [Pause All Print Jobs] is pressed to halt printing. Purpose To check conditions of use, settings and transmission procedures of the fax. Method 1. Press the start key. 2. Select the item to be output using the cursor up/down keys. 3. Press the start key. The selected list is output. Display Description SETTING LIST Outputs a list of software switches, self telephone number, confidential boxes, ROM versions and other information. ACTION LIST Outputs a list of error history, transmission line details and other information. SELF ST REPORT Outputs a list of settings in maintenance mode (own-status report) regarding fax transmission only. PROTOCOL LIST Outputs a list of transmission procedures. ERROR LIST Outputs a list of error. ADDR BOOK (No.) Outputs address book in order IDs were added ADDR BOOK (Name) Outputs address book in order of names ONE-TOUCH LIST Outputs a list of one-touch. GROUP LIST Outputs a list of group. Completion Press the stop key. The screen for selecting a maintenance item No. is displayed
- U699Error codeSetting the software switches Description Sets the software switches on the FAX control PWB individually. Purpose To change the setting when a problem such as split output of received originals occurs. Since the communication performance is largely affected, normally this setting need not be changed. Method 1. Press the start key. 2. Press [SW No.]. 3. Enter the desired software switch number (3 digits) using the numeric keys and press the enter key. 4. Use numeric keys 7 to 0 to switch each bit between 0 and 1. 5. Press the start key to set the value. Completion Press the stop key. The screen for selecting a maintenance item No. is displayed. List of Software Switches of Which the Setting Can Be Changed <Communication control procedure> No. Bit Item 36 7654 Coding format in transmission 3210 Coding format in reception 37 5 33600 bps/V34 4 31200 bps/V34 3 28800 bps/V34 2 26400 bps/V34 1 24000 bps/V34 0 21600 bps/V34 38 7 19200 bps/V34 6 16800 bps/V34 5 14400 bps/V34 4 12000 bps/V34 3 9600 bps/V34 2 7200 bps/V34 1 4800 bps/V34 0 2400 bps/V34 41 3 FSK detection in V.8 42 4 4800 bps when low-speed setting is active 2 FIF length in transmission of more than 4 times of DIS/DTC signal
- U917Error codeError Codes Codes Description Codes Description e002 Parameter error e31e User managements error e003 File write error e31f User managements open error e004 File initialization error e320 User managements error e005 File error e410 Box file open error e006 Processing error e411 Box error in writing e010 Address book clear error (contact) e412 Box error in reading e011 Address book open error (contact) e413 Box list error e012 Address book list error (contact) e414 Box list error e013 Address book list error (contact) e415 Box error e014 Address book clear error (group) e416 Box error e015 Address book open error (group) e417 Box open error e016 Address book list error (group) e418 Box close error e017 Address book list error (group) e419 Box creation error e110 Job accounting clear error e41a Box creation error e111 Job accounting open error e41b Box deletion error e112 Job accounting open error e41c Box movement error e113 Job accounting error in writing e510 Program error in writing e114 Job accounting list error e511 Program error in reading e115 Job accounting list error e710 Fax memory open error e210 One-touch open error e711 Fax memory initialization error e211 One-touch lis
- U977Error codeData capture mode Description Store the print data sent to the machine into USB memory. Purpose In case to occur the error at printing, check the print data sent to the machine. Method 1. Insert USB memory in USB memory slot. 2. Turn the main power switch on. 3. Enter the maintenance item. 4. Press the start key. 5. Select [EXECUTE]. 6. Press the start key. 7. Send the print data to the machine. Once the print data is stored into USB memory, OK will be displayed. Completion Press the stop key. The screen for selecting a maintenance item No. is displayed
- U1930Error codeTransmission failed because an error occurred during JBIG encoding
- Vg1Error codeGrid voltage correction value
- YC1Error codeGround SBM drive control signal SBM drive control signal SBM drive control signal SBM drive control signal MPSOL: On/Off 24 V DC power from EPWB RFM: Full speed/Half speed/Off TEMS detection voltage (temperature) 5 V DC power from EPWB TEMS clock signal TEMS clock signal TEMS detection voltage (humidity)
- YC2Error code24 V DC power to paper feeder Serial communication clock signal 5 V DC power to paper feeder Paper feeder ready signal Paper feeder select signal (0) Paper feeder select signal (1) Paper feeder select signal (2) Serial communication data signal input Serial communication data signal output Ground
- YC5Error codeSerial communication data signal output 24 V DC power from CPWB-L (via ILSW) 24 V DC power from CPWB-L (via ILSW) Ground Ground Ground Ground Ground 24 V DC power from CPWB-L 5 V DC power from CPWB-L 5 V DC power from CPWB-L 5 V DC power from CPWB-L 5 V DC power to CPWB-L
- YC10Error codeCSSW: On/Off CSSW: On/Off CSSW detection voltage CSSW: On/Off
- YC12Error codePM ready signal PM: On/Off Laser output enable signal Horizontal synchronizing signal Serial busy signal Serial communication direction change signal Engine interruption signal Serial communication data signal input Serial communication data signal output Serial communication clock signal Reset signal 24 V DC power to MPWB 5 V DC power to MPWB 5 V DC power to MPWB Ground 5 V DC power to MPWB Ground Ground Ground 24 V DC power to MPWB
- YC13Error codePM ready signal PM: On/Off Laser output enable signal Horizontal synchronizing signal Serial busy signal Serial communication direction change signal Engine interruption signal Serial communication data signal input Serial communication data signal output Serial communication clock signal Reset signal
- YC14Error codeSerial communication clock signal