- d3-01Error coded3-01 to d3-04 allow programming of three prohibited frequency reference points for eliminating problems with resonant vibration of the motor / machine. This feature does not eliminate the selected frequency values, but accelerates and decelerates the motor through the prohibited bandwidth. The parameters must be according to the rule d3-01 ≥ d3-02 ≥ d3-03
- d4-05Error code0: Bias value is held if no input Up 2 or Down 2 is active. 1: When the Up 2 reference and Down 2 reference are both on or both off, the applied bias becomes 0. Currently selected accel / decel. times are used. Enabled only when d4-03 = 0
- ded20Error codeThe torque reference exceeded 20% during Auto-Tuning
- ded80Error codeThe no-load current exceeded 80% of the drive rated current during Auto-Tuning
- E1-01Error codeInput Voltage Reference
- E1-04Error codeE1-04 and E1-06 to E1-13 can only be changed when E1-03 is set to F. In this case, the setting for E1-08 will be disregarded. When E1-13 = 0.0 V, then the drive uses the value set to E1-05 to control the voltage level. VACrms Out(V) E1-05 E1-12 E1-13 E1-08 E1-10 E1-09 E1-07 E1-06 E1-11 E1-04 Frequency (Hz)
- E1-05Error codeMaximum Voltage
- E1-08Error codeMiddle Output Frequency Voltage
- E1-10Error codeMinimum Output Frequency Voltage
- E1-12Error codeMiddle Output Frequency Voltage 2
- E1-13Error codeBase Voltage
- E2Error codeMotor 1 Parameters .............................................................................................................164
- E2-01Error codeMotor Rated Current
- E2-02Error codeSets the motor rated slip in Hertz. Automatically set during rotational Auto-Tuning
- E2-03Error codeSets the magnetizing current of the motor in Ampere. Automatically set during rotational Auto-Tuning. Note: Set E2-03 (Motor No-Load Current) before making changes to E2-01. An oPE01 error will be triggered if E2-01 < E2-03
- E2-04Error codeNumber of Motor Poles
- E2-05Error codeSets the phase-to-phase motor resistance in ohms. Automatically set during Auto-Tuning
- E2-06Error codeSets the voltage drop due to motor leakage inductance as a percentage of motor rated voltage. Automatically set during Auto-Tuning
- E2-08Error codeSets the motor iron saturation coefficient at 75% of magnetic flux. Automatically set during Auto-Tuning
- E2-09Error codeSets the motor mechanical loss as a percentage of motor rated power (kW). Adjust in the following circumstances: When there is a large amount of torque loss due to motor bearing friction. When there is a large amount of torque loss
- E2-10Error codeSets the motor iron loss in watts (W)
- E2-11Error codeMotor Rate Capacity
- E2-12Error codeSet to the motor iron saturation coefficient at 130% of magnetic flux. Automatically set during rotational Auto-Tuning
- E3Error codeV/f Characteristics for Motor 2 .............................................................................................166
- E3-01Error codeMotor 2 Control Method Selection
- E3-04Error codeMotor 2 Max Output Frequency
- E3-05Error codeMotor 2 Max Voltage
- E3-06Error codeMotor 2 Base Frequency
- E3-07Error codeMotor 2 Mid Output Freq
- E3-08Error codeMotor 2 Mid Output Freq. Voltage
- E3-09Error codeMotor 2 Min. Output Freq
- E3-10Error codeMotor 2 Min. Output Freq. Voltage
- E3-11Error codeMotor 2 Mid Output Frequency 2
- E3-12Error codeMotor 2 Mid Output Frequency Voltage 2
- E3-13Error codeMotor 2 Base Voltage
- E3-14Error codeMotor 2 Slip compensation gain
- E4Error codeMotor 2 Parameters .............................................................................................................167
- E4-01Error codeSets the motor 2 nameplate full load current in amperes (A). This value is automatically set during Auto-Tuning
- E4-02Error codeSets the motor 2 rated slip in Hz. Automatically set during Auto-Tuning
- E4-03Error codeSets the magnetizing current of motor 2 in Ampere. Automatically set during Rotational Auto-Tuning
- E4-04Error codeSets the number of poles of motor 2. This value is automatically set during Auto-Tuning
- E4-05Error codeSets the phase-to-phase resistance of motor 2 in ohms. Automatically during Auto-Tuning
- E4-06Error codeSets the voltage drop due to motor leakage inductance as a percentage of rated voltage of motor 2. Automatically set during Auto-Tuning
- E4-07Error codeSet to the motor iron saturation coefficient at 50% of magnetic flux. Automatically set during Rotational Auto-Tuning
- E4-08Error codeSet to the motor iron saturation coefficient at 75% of magnetic flux. This value is automatically set during Rotational Auto-Tuning
- E4-09Error codeSets the motor mechanical loss as a percentage of motor rated power (kW) capacity. Adjust in the following circumstances: • When there is a large amount of torque loss due to motor bearing friction. • When there is a large amount of torque loss
- E4-10Error codeSets the motor iron loss in watts
- E4-11Error codeSets the motor rated capacity in kW. Automatically set during Auto-Tuning
- E4-12Error codeSet to the motor iron saturation coefficient at 130% of magnetic flux. Automatically set during Rotational Auto-Tuning
- E20Error codensure the power supply voltage is correct: 0 V class: single-phase 200 to 240 Vac 50/60 Hz 0 V class: 3-phase 200 to 240 Vac 50/60 Hz 0 V class: 3-phase 380 to 480 Vac 50/60 Hz