Yaskawa inverter CIMR-VC All models error codes
Codes
- E4-14Error codeSets the slip compensation gain for motor 2. The function is the same as C3-01 for motor 1. Refer to C3-01: Slip Compensation Gain on page 144
- E4-15Error codeSets the torque compensation gain for motor 2. The function is the same as C4-01 for motor 1. Refer to C4-01: Torque Compensation Gain on page 145
- E5Error codePM Motor Settings ...............................................................................................................169
- E5-01Error code"Reverse run prohibited" is selected. If b1-04 (Reverse Prohibit Operation) is set to 1 (reverse run prohibited), the drive will not accept a reverse run command. The drive prohibits reverse rotation. A Reverse run signal has not been entered, although 3-Wire sequence is selected.
- E5-02Error codeMotor Rated Capacity (for PM motors)
- E5-03Error codeMotor Rated Current (for PM motors)
- E5-04Error codeMotor Poles (for PM motors)
- E5-05Error codeMotor Stator Resistance (for PM motors)
- E5-06Error codeMotor d Axis Inductance (for PM motors)
- E5-07Error codeMotor q Axis Inductance (for PM motors)
- E5-09Error codeMotor Induction Voltage Constant 1 (for PM motors)
- E5-24Error codeMotor Induction Voltage Constant 2 (for PM motors)
- E5-39Error codeSets the current detection delay time at the time of d-Axis and q-Axis current feedback calculation. Changing this parameter from the default setting is not normally required
- een10Error code<1>
- Er-01Error codeMotor data fault The input motor data are not valid. (e.g. the base frequency and base speed do not fit)
- Er-02Error codeMinor Fault • The wiring is faulty. • The load is too heavy
- Er-04Error codeResistance fault • Wrong input data • Auto tuning exceeded the given time frame. • Calculated values out of range
- Er-05Error codeNo-Load Current Error • Incorrect data was entered. • Auto tuning took too long. • Calculated values out of range
- Er-08Error codeRated Slip Error • Wrong data input • Auto tuning exceeded the given time frame. • Calculated values out of range
- Er-09Error codeAcceleration error The motor did not accelerate for the specified acceleration time
- Er-11Error codeMotor speed fault The torque reference was too high
- Er-12Error codeCurrent detection error • One or all output phases are lost. • Current is either too low or exceeds the drives rating. • The current sensors are faulty
- F1Error codeError Detection for V/f Control with PG ................................................................................172
- F1-02Error codeSets stopping method when a PG open circuit fault (PGo) occurs. Refer to parameter F1-14. 0: Ramp to Stop - Decelerate to stop using the active deceleration time. 1: Coast to Stop 2: Fast-stop - Decelerate to stop using the deceleration time in C1-09. 3: Alarm only - Drive continues operation
- F1-03Error codeSets the stopping method when an overspeed (oS) fault occurs. Refer to F1-08 and F1-09. 0: Ramp to stop - Decelerate to stop using the active deceleration time. 1: Coast to stop 2: Fast-stop - Decelerate to stop using the deceleration time in C1-09. 3: Alarm Only - Drive continues operation
- F1-04Error codeSets the stopping method when a speed deviation (dEv) fault occurs. Refer to F1-10 and F1-11. 0: Ramp to stop - Decelerate to stop using the active deceleration time. 1: Coast to stop 2: Fast-stop - Decelerate to stop using the deceleration time in C1-09. 3: Alarm only - Drive continues operation
- F1-08Error codeSets the speed feedback level which has to be exceeded for the time set in F1-09 before an oS fault will occur. Set as a percentage of the maximum output frequency (E1-04)
- F1-09Error codeSets the time in seconds for which the speed feedback has to exceed the overspeed detection level F1-08 before an oS fault will occur
- F1-10Error codeSets the allowable deviation between motor speed and frequency reference before a speed deviation fault (dEv) is triggered. Set as a percentage of the maximum output frequency (E1-04)
- F1-11Error codeSets the time in seconds for which a deviation between motor speed and frequency reference has to exceed the speed deviation detection level F1-10 before a dEv fault will occur
- F1-14Error codeSets the time for which no PG pulses must be detected before a PG Open (PGo) fault is triggered
- F6Error codeSerial Communications Option Card Settings......................................................................173
- F6-01Error codeSelects the operation after a communications error occurred. 0: Ramp to stop using current accel/decel time 1: Coast to stop 2: Fast-stop using C1-09 3: Alarm only 4: Alarm and Run at d1-04 <9> <10> 5: Alarm and Ramp to stop <9>
- F6-02Error codeSets when an external fault from a comm option is detected. 0: Always detected 1: Detection during Run only
- F6-03Error codeAn external fault was received from the PLC with other than F6-03 = 3 “alarm only” (the drive continued to run after external fault)
- F6-04Error codeSet the delay time for error detection if a bus error occurs
- F6-08Error code0: Communication-related parameters (F6-oo and F7-oo) are not reset when the drive is initialized using A1-03. 1: Reset all communication-related parameters (F6-oo and F7-oo) when the drive is initialized using A1-03
- F6-11Error codeCC-Link Communications Speed
- F6-14Error codeSelects if a BUS fault can be automatically reset. 0: Disabled 1: Enabled
- F6-25Error code0: Ramp to stop. Decelerate using the deceleration time in C1-02. 1: Coast to stop 2: Fast stop. Decelerate using the deceleration time in C1-09. 3: Alarm only
- F6-26Error codeSets the number of option communication errors (bUS)
- F6-36Error codeCANopen Communication Speed
- F6-51Error codeDeviceNet Communication Speed
- F6-54Error codeSelects if an EF0 fault is detected when no data are received from the master. <4> 0: Detection enabled 1: No detection
- F6-57Error codeSets the scaling factor for the output current monitor in DeviceNet Class ID 2AH Object
- F6-60Error codeSets the scaling factor for the voltage monitor in DeviceNet Class ID 2AH Object
- F6-62Error codeSets the heartbeat interval for DeviceNet communications
- F7-18Error codeCommunication Speed Selection
- F7-21Error codeCommunication Loss Time Out
- H1-03Error code24: External Fault (N.O., always detected, coast to stop)