Yaskawa inverter CIMR-JC 200 V Class error codes
Codes
- L8-18Error codeSelects the software current limit function. Typically no adjustment is required. 0: Disabled 1: Enabled
- L8-38Error codeProvides protection to the IGBTs by reducing the carrier frequency at low speeds. 0: Disabled 1: Enabled below 6 Hz 2: Enabled for the whole speed range Current ND HD 200 V Single Phase C6-02 80% of HD Carrier Frequency 400 V: 60% of HD 0 2 10 (8) 15
- n1-02Error codeSets the gain for the Hunting Prevention Function. If the motor vibrates while lightly loaded, increase the gain by 0.1 until vibration ceases. If the motor stalls, decrease the gain by 0.1 until the stalling ceases
- o1-02Error codeSelects the monitor to display upon power-up. 1: Frequency Reference (U1-01) 2: Forward/Reverse 3: Output Frequency (U1-02) 4: Output Current (U1-03)
- o2-02Error codeDetermines if the STOP key on the digital operator will stop the drive when operating from the external terminals or via serial communication. 0: Disabled 1: Enabled
- o2-06Error codeSets drive action when the digital operator is removed in LOCAL mode or with b1-02 = 0 (valid for optional remote operator only). 0: The drive will continue operation 1: The drive will trigger a fault (oPr) and the motor will coast to stop
- o3-01Error codeSelects the copy function operation. 0: No action 1: READ - All parameters are read from the drive and stored in the LED operator. 2: COPY - All parameters are copied from the LED operator to the drive. 3: VERIFY - Parameter settings in the drive are compared to those in the LED operator. NOTE: When using the copy function, the drive model number (o2-04) and the software number (U1-14) must match or an error will occur
- o4-03Error codeCooling Fan Maintenance Setting (Operation Time)
- o4-11Error codeSelects if U2-oo (Fault History) monitors are reset at drive initialization. 0: Saves the fault monitor data 1: Resets the fault monitor data
- oL2Error code150% of drive rated Heavy Duty current for 60 s
- RS-232CError codeRS232C communications interface to connect the drive to a PC or the optional copy unit
- RS-422Error codeInterface for RS-422/485 communications using the MEMOBUS/Modbus RTU protocol
- T1Error codeDrive output
- to40Error code3/4 (depending on drive size)
- U1-03Error codeDisplays the output current
- U1-06Error codeDisplays the output voltage
- U1-07Error codeDisplays the DC bus voltage
- U1-11Error codeDisplays the output terminal status. Multi-Function Digital Output (fault) (terminal MA/MB-MC)
- U1-19Error codeDisplays the contents of a MEMOBUS/Modbus error. CRC Error Data Length Error Not Used Parity Error Overrun Error Framing Error Timed Out Not Used
- U2Error codeFault History.........................................................................................................................117
- U2-01Error codeDisplay of the current fault
- U2-02Error codeDisplay of the previous fault. o4-11 resets the values for U2-02
- U4-04Error codeCooling Fan
- U4-08Error codeDisplays the heatsink temperature
- U4-13Error codeDisplays the peak hold current during run