Yaskawa inverter CIMR-JC 200 V Class error codes
Codes
- A0001Error codeHeavy Duty Max. Motor Capacity Rated Output No. kW Current A 0001 0.1 0.8 0002 0.2 1.6 0003 0.4 3.0 0006 0.75 5.0 0010 1.5 8.0
- b1-01Error codeSelects the frequency reference input source. 0: Operator - Digital preset speed d1-01 to d1-08 1: Terminals - Analog input terminal A1 2: MEMOBUS/Modbus communications (option) 3: Potentiometer (option)
- b1-07Error codeDetermines the operation when the Run command source is switched from LOCAL to REMOTE or between REMOTE and MEMOBUS/Modbus communication. 0: External Run command has to be cycled at the new source to be activated. 1: External Run command at new source is accepted immediately
- b1-17Error codeDetermines the operation when a Run command is active at power up of the drive. 0: Run command not issued, needs to be cycled 1: Run command issued, motor operation start
- b2-01Error codeDC Injection Current (b2-02)
- b2-02Error codeDC Injection Current (b2-02)
- b2-04Error codeSets DC Injection Braking time at stop. When b1-03 = 0, this parameter sets the amount of DC Injection time applied to the motor at the end of the decel ramp. Disabled when set to 0.00
- C1-01Error codeAdjusting accel and decel times will affect the torque presented to the motor during acceleration or deceleration
- C1-09Error codeSets the time to decelerate from maximum frequency to 0 for the multi-function input fast-stop function. Note: This parameter is also used by selecting “Fast-Stop” as a Stop Method when a fault is detected
- C3Error codeMotor Slip Compensation
- C4Error codeMotor Torque Compensation
- C4-01Error codeSets the gain for the automatic torque (voltage) boost function and helps to produce better starting torque.
- C6-01Error codeRated Output Current
- d3-01Error coded3-01 to d3-04 allow programming of three prohibited frequency reference points for eliminating problems with resonant vibration of the motor/machine. This feature does not eliminate the selected frequency values, but accelerates and decelerates the motor through the prohibited bandwidth. The parameters must be according to the rule d3-01 ≥ d3-02
- E1-01Error codeInput Voltage Reference
- E1-05Error codeMaximum Voltage
- E1-08Error codeMid Output Frequency Voltage
- E1-10Error codeMinimum Output Freq. Voltage
- E2Error codeMotor 1 Parameters ...............................................................................................................88
- E2-01Error codeMotor Rated Current
- E2-02Error codeSets the motor rated slip in Hertz
- E2-03Error codeSets the magnetizing current of the motor in Ampere
- E2-05Error codeSets the phase-to-phase motor resistance in ohms
- En20Error codesure the power supply voltage is correct: 0 V class: single-phase 200 to 240 Vac 50/60 Hz 0 V class: 3-phase 200 to 240 Vac 50/60 Hz 0 V class: 3-phase 380 to 480 Vac 50/60 Hz
- H1-03Error code24: External Fault
- H1-04Error code14: Fault Reset
- H4-02Error codeSets terminal AM output level when selected monitor is at 100%. Maximum output voltage is 10 V
- H5Error codeMEMOBUS/Modbus Serial Communication ........................................................................101
- H5-01Error codeSelects drive slave number (address) for MEMOBUS/Modbus communication. Cycle power for the setting to take effect
- H5-02Error codeSelects the baud rate for MEMOBUS/Modbus communication. Cycle power for the setting to take effect. 0 : 1200 bps 1 : 2400 bps 2 : 4800 bps 3 : 9600 bps 4 : 19200 bps 5 : 38400 bps
- H5-03Error codeSelects the communication parity for MEMOBUS/Modbus communication. Cycle power for the setting to take effect. 0: No parity 1: Even parity 2: Odd parity
- H5-04Error code• Remove the cause of the external fault. • Remove the external fault input from the PLC
- H5-05Error codeEnables or disables the communications timeout fault (CE). 0: Disabled - A communication loss will not cause a communication fault. 1: Enabled - If communication is lost for more than 2 seconds, a CE fault will occur
- L1Error codeMotor Protection Functions ..................................................................................................102
- L1-01Error codeMotor Protection Function Selection
- L1-02Error codeSets the motor thermal overload protection (oL1) time. A larger L1-02 time will increase the time for an oL1 fault to occur. This parameter does not typically require adjustment. Should be set in accordance with the overload tolerance of the motor
- L2-01Error codeEnables and disables the momentary power loss function. 0: Disabled - Drive trips on (Uv1) fault when power is lost. 1: Power Loss Ride-Thru Time - Drive will restart if power returns within the Power Loss Ride-Thru Time. 2: CPU Power Active - Drive will restart if power returns as long as the CPU is working
- L3-01Error code• Prevents motor speed loss and overvoltage. Used when the load is too heavy and also during sudden acceleration/deceleration. • Adjustment is not normally required because Stall Prevention is enabled as a default.
- L3-02Error codeUsed when L3-01 = 1. 100% is equal to the drive rated current. Decrease the set value if stalling or excessive current occurs with default setting
- L3-04Error codeWhen using a braking resistor, use setting "0". 0: Disabled - The drive decelerates at the active deceleration rate. If the load is too large or the deceleration time is too short, an ov fault may occur. 1: General Purpose - The drive decelerates at the active deceleration rate, but if the main circuit DC bus voltage reaches the Stall Prevention level, deceleration will stop. Deceleration will continue once the DC bus level drops below the Stall Prevention level. 4: Overexcitation Deceleration - Decelerates with the flux level determined by n3-13 (Overexcitation Gain)
- L3-05Error codeSelects the Stall Prevention method to use to prevent drive faults during run. 0: Disabled - Drive runs a set frequency. A heavy load may cause the drive to trip on an oC or oL fault. 1: Decel Time 1 - The drive will decelerate at Decel Time 1 (C1-02) if the output current exceeds the level set by L3-06. Once the current level drops below the L3-06 level, the drive will accelerate back to its frequency reference at the active acceleration rate. 2: Decel Time 2 - Same as setting 1 except the drive decelerates at Decel Time 2 (C1-04). When output frequency is 6 Hz or less, Stall Prevention during run is disabled regardless of the setting in L3-05
- L3-06Error codeEnabled when L3-05 is set to "1" or "2". 100% is equal to the drive rated current. Decrease the set value if stalling or excessive current occurs with the default settings. Upper level is determined by C6-01 and L8-38
- L5Error codeFault Restart.........................................................................................................................107
- L5-01Error codeSets the counter for the number of times the drive attempts to restart when one of the following faults occurs: oC, ov, PF, rH, oL1, oL2, oL3, Uv1. When the drive operates without fault for 10 minutes, the counter will be reset
- L6-01Error codeSelects the overtorque operation. Overtorque is determined by the settings in parameters L6-02 and L6-03. The multi-function output settings (H2-01= B and 17) are also active if programmed. 0: Disabled 1: oL3 at Speed Agree - Alarm (overtorque detection only active during Speed Agree and operation continues after detection). 2: oL3 at RUN - Alarm (overtorque detection is always active and operation continues after detection). 3: oL3 at Speed Agree - Fault (overtorque detection only active during Speed Agree and drive output will shut down on an oL3 fault). 4: oL3 at RUN - Fault (overtorque detection is always active and drive output will shut down on an oL3 fault)
- L6-02Error codeSets the overtorque detection level. 100% is equal to the motor rated current
- L8-01Error code0: Disabled. The drive will not provide overheat protection. Supply separate means of overheat protection. 1: Enabled. Braking Resistor is protected from overheat
- L8-05Error codeSelects the detection of input current phase loss, power supply voltage imbalance, or main circuit electrolytic capacitor deterioration. 0: Disabled 1: Enabled
- L8-10Error codeControls the heatsink cooling fan operation. 0: Fan On-Run Mode - Fan will operate only when the drive is running and for 60 seconds after stop. 1: Fan always on - Cooling fan operates whenever the drive is powered up
- L8-12Error codeUsed to input the ambient temperature. This value adjusts the drive oL2 detection level