Yaskawa All models error codes
Codes
- b1-11Error codeAfter a Run command has been entered, the drive must wait for the time set to b1-11 to pass before it can begin to operate the motor
- b2-01Error codeDC Injection Current (b2-02)
- b2-02Error codeDC Injection Current (b2-02)
- b2-08Error codeSets the magnetic flux compensation as a percentage of the no-load current value (E2-03)
- b2-10Error codeAn input terminal set for DC Injection Braking 2 (H1- = 60) will make the drive use the current level set in b2-10 for DC Injection
- b2-12Error codeShort Circuit Brake Time at Start
- b2-13Error codeSets the Short-Circuit brake operation time at stop. Used to stop a motor rotating due to inertia. Disabled when set to 0.00 seconds. <32>
- b3-02Error codeSets the current level at which the speed is assumed to be detected and Speed Search is ended. Set as a percentage of the drive rated current
- b3-06Error codeSets the current injected to the motor at the beginning of Estimation type Speed Search. Set as a factor of the motor rated current
- b3-10Error codeSets the gain which is applied to the speed detected by Speed Estimation Speed Search before the motor is reaccelerated. Increase this setting if ov occurs when performing Speed Search
- b3-17Error codeSets the Speed Search restart current level as a percentage of the drive rated current
- b5-12Error codeConfigures the PID feedback loss detection. With all setting a digital output programmed for H2-01/02/03 = 3E/3F (PID feedback low/PID feedback high) is operated when the detection condition becomes true. 0: Digital output only. 1: Feedback loss detected when PID enabled. Alarm output, operation is continued without triggering a fault contact. 2: Feedback loss detected when PID enabled. Fault output, operation is stopped and a fault contact is triggered. 3: Feedback loss detection even when PID is disabled by digital input. No alarm/fault output. 4: PID Feedback error detection even when PID is disabled by digital input. An alarm is triggered and the drive continues to run. 5: PID Feedback error detection even when PID is disabled by digital input. Fault is triggered and output is shut off
- b5-14Error codeYES
- b5-18Error codeoPE08
- b5-37Error codeYES
- b6-01Error codeDwell Reference at Start
- b8-06Error codeSets the limit for the voltage search operation performed by Energy Savings in V/f Control. Disabled when set to 0%
- b20Error codeReference Torque Input Read Error(Detected when the servo is ON.)
- b31Error codeCurrent Detection Error 1
- b32Error codeCurrent Detection Error 2
- b33Error codeCurrent Detection Error 3
- bF0Error codeSystem Alarm 0
- bF1Error codeSystem Alarm 1
- bF2Error codeSystem Alarm 2
- bF3Error codeSystem Alarm 3
- bF4Error codeSystem Alarm 4
- C1-01Error codeAcceleration Time 1
- C1-05Error codeAcceleration Time 3 (Motor 2 Accel Time 1)
- C1-06Error codeDeceleration Time 3 (Motor 2 Decel Time 1)
- C1-07Error codeAcceleration Time 4 (Motor 2 Accel Time 2)
- C1-08Error codeDeceleration Time 4 (Motor 2 Accel Time 2)
- C1-09Error codeSets the time to decelerate from maximum frequency to 0 for the multi-function input fast-stop function. Note: This parameter is also used by selecting “Fast-Stop” as a Stop Method when a fault is detected
- C2SError codebağlantılarının yapılması için temel bilgilerin yanı sıra, hata tanısı, bakım ve parametre ayarlarına genel bir bakışı kapsar. Bu kitapta yazan bilgileri, sürücünün uygulama amaçlı bir deneme çalışmasına hazırlanması için ve temel işletim için kullanınız
- C3-01Error codeMotor 1 için kullanılan motor slip kompanzasyon fonksiyonu için kazancı ayarlar
- C3-02Error codeMotor 1 için kullanılan slip kompanzasyon fonksiyonu gecikme süresini ayarlar
- C3-03Error codeSets the slip compensation upper limit. Set as a percentage of motor rated slip (E2-02). Disabled when Simple V/f Control with PG (H6-01 = 3) is used
- C4-02Error codeSets the torque compensation filter time. Increase this setting when motor oscillation occurs. Reduce the setting if there is not enough response from the motor
- C4-03Error codeSets torque compensation at forward start as a percentage of motor torque
- C4-04Error codeSets torque compensation at reverse start as a percentage of motor torque
- C4-06Error codeSets the torque compensation time 2. When an ov fault occurs with sudden load changes or at the and of an acceleration, increase the setting. Note: Adjustment is not normally required. If adjusted then AFR time 2 (n2-03) should be adjusted too
- C6-01Error codeRated Output Current
- C6-02Error codeThe output of the drive is a series of high frequency pulses (PWM), so there is a certain amount of leakage current. This may cause the ground fault interrupter to operate and cut off the drive input power.
- C6-05Error codeLED Operator Display
- C80Error codeAbsolute Encoder Clear Error and Multiturn Limit Setting Error
- C90Error codeEncoder Communications Error
- C91Error codeEncoder Communications Position Data Error
- C92Error codeEncoder Communications Timer Error
- CA0Error codeEncoder Parameter Error
- Cb0Error codeEncoder Echoback Error
- CC0Error codeMultiturn Limit Disagreement