Viessmann nem alma cihazı Tüm modeller arıza kodları
Kodlar
- bCArıza koduCommunication er- ror, Vitotrol remote control, heating cir- cuit 1 (without mix- er)
- bdArıza koduCommunication er- ror, Vitotrol remote control, heating cir- cuit 2 (with mixer)
- bEArıza koduCommunication er- ror, Vitotrol remote control, heating cir- cuit 3 (with mixer)
- bFArıza koduIncorrect LON communication module
- C1Arıza koduCommunication er- ror, EA1 extension
- C2Arıza koduCommunication er- ror, solar control module or Vitosolic
- C3Arıza koduCommunication er- ror, AM1 extension
- C4Arıza koduCommunication er- ror, OpenTherm extension
- CdArıza koduCommunication er- ror, Vitocom 100, type GSM
- CFArıza koduCommunication er- ror, LON communi- cation module
- d5Arıza kodu
- d6Arıza koduHeating circuit pump stays in con- trol mode at signal "External block- ing"
- d7Arıza koduHeating circuit pump stays in con- trol mode at signal "External de- mand"
- d8Arıza koduInput DE3 at EA1 extension reports a fault
- dAArıza koduShort circuit, room temperature sen- sor, heating circuit 1 (without mixer)
- dbArıza koduShort circuit, room temperature sen- sor, heating circuit 2 (with mixer)
- dCArıza koduShort circuit, room temperature sen- sor, heating circuit 3 (with mixer)
- ddArıza koduLead break, room temperature sen- sor, heating circuit 1 (without mixer)
- dEArıza koduLead break, room temperature sen- sor, heating circuit 2 (with mixer)
- dFArıza koduLead break, room temperature sen- sor, heating circuit 3 (with mixer)
- E0Arıza koduExternal LON sub- scriber fault
- E1Arıza koduSoftware ver- sion Solar control module, type SM1
- E2Arıza koduHeating water flow rate too low during calibration. Flow switch has shut down
- E3Arıza kodu
- E4Arıza koduFault, 24 V supply voltage
- E5Arıza koduFlame amplifier fault
- E6Arıza kodu
- E7Arıza kodu
- E8Arıza koduIonisation current lies outside the permissible range
- EAArıza koduIonisation current outside permissible range during cali- bration (excessive deviation from pre- vious level)
- EA1Arıza koduNo function External demand, DHW circulation pump External demand (based on boiler application type) External blocking Call for heat demand (based on boiler application type)
- EbArıza koduRepeated flame loss during calibra- tion
- ECArıza koduParameter fault during calibration
- EdArıza koduInternal fault
- EEArıza kodu
- EFArıza koduFlame is lost imme- diately after it has formed (during safety time)
- F0Arıza koduInternal fault
- F1Arıza koduScreed drying disabled (only for weather-compensated control units)
- F2Arıza koduBoiler water tem- perature sensor has responded
- F3Arıza koduFlame signal is al- ready present at burner start
- F5Arıza koduBoiler circuit pump run-on time in heating mode: 12 min (only for constant temperature control units)
- F6Arıza kodu
- F7Arıza kodu
- F8Arıza kodu
- F9Arıza kodu
- FAArıza koduFan idle state not reached
- FCArıza koduGas train faulty, faulty modulation valve control or flue gas path blocked
- put21Arıza kodu
- ver14Arıza kodu