Mitsubishi Electric PU arıza kodları
Kodlar
- F1Arıza kodu
- F2Arıza koduL3-phased open phase detection Detect open phase two seconds after power on.
- F3Arıza kodu
- F4Arıza kodu
- F7Arıza kodu
- F9Arıza kodu
- FAArıza kodu51CM connector open Abnormal if 51CM connector circuit is open for three minutes continuously after power on. 51CM: Thermal Relay
- P1Arıza kodu
- P2Arıza kodu
- P4Arıza kodu
- P5Arıza kodu
- P6Arıza kodu
- P8Arıza kodu
- P9Arıza kodu
- U1Arıza kodu
- U2Arıza kodu
- U3Arıza kodu
- U4Arıza kodu
- U6Arıza koduCompressor over current (overload) breaking (only P35Y-P140Y) Abnormal if current value exceeds overload set value during compressor operation. P35 ·····4.5 P50 ·····5.8 P60 ·····6.4 P71 ·····8.0 P100 ·····9.0 P125 ·····15.0 P140 ·····17.0
- UDArıza koduOver heat protection (over-load operation protection/abnormal fan) Abnormal if pipe thermistor detects the value that exceeds set value during compressor operation. P1.6-P6······70:
- UEArıza kodu
- UFArıza koduCompressor over current (start-up locked) breaking Abnormal if compressor current exceeds 1.2 times of overload set value.
- UHArıza kodu
- ULArıza koduAbnormal low pressure (63H worked) Abnormal if connector (63L) is open (under0.03MPa) during compressor operation.