- E91Arıza koduThrottle sensor 1 LOW fault (IDLE)
- E9008Arıza koduCAN ID module off (ECU to ID)
- E9010Arıza koduLOW ambient pressure sensor fault
- E9021Arıza kodu5 V DC supply 1 LOW fault
- E9022Arıza kodu5 V DC supply 2 LOW fault
- E9023Arıza kodu5 V DC supply 3 LOW fault
- E9024Arıza koduSupply voltage of sensor detecting water in fuel BELOW NORMAL
- E9025Arıza koduSelf-test cut-off paths, monitoring
- E9026Arıza koduSelf-test cut-off paths, HIGH processor voltage check
- E9027Arıza koduSelf-test cut-off paths, LOW processor voltage check
- E9030Arıza koduShort circuit to EARTH, ECU main relay1
- E9031Arıza koduShort circuit to EARTH, ECU main relay2
- E9032Arıza koduShort circuit to EARTH, ECU main relay3
- E9033Arıza koduECU cut-off does not work
- E9034Arıza koduECU cut-off did not work last time
- E9036Arıza koduTotal restart after 3 recoveries in 2 seconds
- E9070Arıza kodu
- E9071Arıza koduCrankshaft speed signal, too many pulses
- E9072Arıza koduCrankshaft speed sensor, reverse connected
- E9082Arıza koduCam speed sensor, reverse connected
- E9083Arıza koduNo cam speed signal detected
- E9090Arıza koduEngine speed signal evaluation error
- E9100Arıza koduProtection upgrade fault
- E9107Arıza koduInvalid ECU source address selection
- E9131Arıza koduSolenoid valve 1, short circuit to EARTH (bank off)
- E9132Arıza koduSolenoid valve 2, short circuit to EARTH (bank off)
- E9133Arıza koduSolenoid valve 3, short circuit to EARTH (bank off)
- E9134Arıza koduSolenoid valve 4, short circuit to EARTH (bank off)
- E9135Arıza koduSolenoid valve 5, short circuit to EARTH (bank off)
- E9136Arıza koduSolenoid valve 6, short circuit to EARTH (bank off)
- E9150Arıza koduRail pressure, negative deviation
- E9151Arıza koduPRV recognised as OPEN
- E9152Arıza koduFuel filter pressure, fluctuating
- E9153Arıza koduFuel filter pressure sensor, loose contact
- E9170Arıza koduLift pump control (ECU), short circuit to earth
- E9171Arıza koduPreheater control, short circuit to earth
- E9172Arıza koduStart relay control, short circuit to earth (lower side)
- E9173Arıza koduStart relay control, short circuit to earth (upper side)
- E9174Arıza koduMPROP control, short circuit to earth
- E9230Arıza koduEngine specification mismatch
- E9231Arıza koduEngine serial number mismatch
- E9233Arıza koduID module not present
- E9234Arıza kodu
- E9235Arıza koduID module memory fault
- E9236Arıza koduID module additional memory defect
- E9237Arıza koduID module, monitoring reset
- E9238Arıza koduID module, brownout reset
- E9239Arıza koduEngine specification missing
- E9240Arıza koduEngine serial number missing