Hitachi KPI Tüm modeller arıza kodları
Kodlar
- 6-2Arıza kodu10. Error/Operation Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..103
- 7-6Arıza kodu1. Fan Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131
- 7-7Arıza kodu
- 7-8Arıza kodu
- 9-3Arıza kodu
- 13-1Arıza kodu7. Fan-IPDU P.C. Board (MCC-1659) Replacement Procedure . . . . . . . . . . . . . . . . . . . 295
- A1Arıza koduAbnormality of Active Filter
- C05Arıza koduTCC-LINK central control device transmission error
- C06Arıza koduTCC-LINK central control device reception error
- C12Arıza kodu
- CT2Arıza koduCurrent Transformer
- d1-05Arıza koduInstantaneous power failure
- d1-18Arıza kodu
- d1-26Arıza koduAbnormality of high pressure decrease
- d1-36Arıza kodu
- DSW10Arıza koduansmission Setting ired. For End Resistance Cancellation o.1 correctly in INK system. may cause abnormal transmission. ting Before End Resistance pment Cancellation N ON 1 2 1 2
- E01Arıza kodu
- E02Arıza koduRemote controller transmission error
- E03Arıza kodu
- E04Arıza kodu
- E07Arıza kodu
- E09Arıza kodu
- E10Arıza kodu
- E12Arıza koduAutomatic address starting error
- E18Arıza kodu
- E19Arıza kodu
- E23Arıza kodu
- E26Arıza kodu
- E28Arıza kodu
- E31Arıza koduThere is no communication between IPDUs (P.C. boards) in inverter box
- EEArıza kodu
- F01Arıza koduHeat exchanger temperature sensor (TCJ) has been open/short-circuited
- F02Arıza koduHeat exchanger temperature sensor (TC2) has been open/short-circuited
- F03Arıza koduHeat exchanger temperature sensor (TC1) has been open/short-circuited
- F04Arıza koduOutdoor discharge temperature sensor (TD1) has been open/short-circuited
- F05Arıza koduOutdoor discharge temperature sensor (TD2) has been open/short-circuited
- F06Arıza koduOutdoor heat exchanger liquid side temperature sensors (TE1, TE2) have been open/short- circuited
- F07Arıza koduOutdoor liquid temperature sensor (TL1,TL2,TL3) has been open/short-circuited
- F08Arıza kodu
- F09Arıza koduOutdoor heat exchanger gas side temperature sensors (TG1, TG2) have been open/short- circuited
- F10Arıza koduRoom air temperature sensor (TA) has been open/short-circuited
- F11Arıza koduDischarge air temperature sensor (TF) has been open/short-circuited
- F12Arıza koduOutdoor suction temperature sensor (TS1,TS3) has been open/short-circuited
- F13Arıza koduTemperature sensor built into indoor IPM (TH) has been open/short-circuited
- F15Arıza kodu
- F16Arıza kodu
- F17Arıza kodu
- F18Arıza koduDischarge air temperature sensor (TF) has been open/short-circuited
- F23Arıza koduOutput voltage of low pressure sensor (Ps) is zero
- F24Arıza kodu