Fresenius Tüm modeller arıza kodları
Kodlar
- W111Arıza koduUpper heater: Bag sensors, OP-SP not synchronous
- W112Arıza koduLower heater: Bag sensor detuning, no overtemperature
- W113Arıza koduLower heater: Foil sensor detuning, no overtemperature
- W114Arıza koduUpper heater: Bag sensor detuning, no overtemperature
- W115Arıza koduUpper heater: Foil sensor detuning, no overtemperature
- W116Arıza koduLower heater: FET control defective
- W117Arıza koduUpper heater: FET control defective
- W118Arıza koduBattery test: Battery not connected, defective
- W121Arıza koduBlood leak detector: Outside acceptable range, remove filtrate line
- W122Arıza koduBlood leak detector: Alarm-free after attenuation
- W127Arıza koduBlood leak detector: Calibration values missing, incorrect
- W128Arıza koduAudible alarm: Not silenced
- W129Arıza koduAudible alarm: not active
- W130Arıza kodu
- W136Arıza koduBalancing, Scale I, leakage from tubing system, objects
- W137Arıza koduBalancing, Scale II, leakage from tubing system, objects
- W138Arıza koduBalancing, upper scales, leakage from tubing system, objects
- W140Arıza koduBalancing, filtrate scales moved, leakage from tubing system
- W141Arıza kodu
- W142Arıza kodu
- W143Arıza kodu
- W144Arıza kodu
- W145Arıza koduBag change: Overload on SUB scale (CVVHDF)
- W146Arıza koduBag change: Overload on SUB scale 1 (CVVH, HF)
- W147Arıza koduBag change: Overload on SUB scale 2 (CVVH, HF)
- W152Arıza koduBag change: Overload on plasma scale 1 (MPS)
- W153Arıza koduBag change: Overload on plasma scale 2 (MPS)
- W154Arıza koduBag change: Overload on dialysate scale (CVVHDF)
- W155Arıza koduBag change: Overload on dialysate scale 1 (CVVHD)
- W156Arıza koduBag change: Overload on dialysate scale 2 (CVVHD)
- W160Arıza koduBag change: Overload on filtrate scale
- W162Arıza koduLower heater: MPS temperature > 37°C
- W163Arıza koduUpper heater: MPS temperature > 37°C
- W164Arıza koduLower heater: Temperature too high
- W165Arıza koduUpper heater: Temperature too high
- W166Arıza koduBag change: Overload SUB pre (HVCVVH)
- W169Arıza koduLower heater: Foil sensors, OP-SP not synchronous
- W170Arıza koduUpper heater: Foil sensors, OP-SP not synchronous
- W172Arıza koduLower heater: MPS foil temperature too high, risk of hemolysis
- W173Arıza koduUpper heater: MPS foil temperature too high, risk of hemolysis
- W175Arıza koduBattery capacity: Charging voltage too high, battery deactivated, no power failure
- W181Arıza koduBalancing: Movement detected on filtrate scales, leakage from tubing system
- W182Arıza kodu
- W184Arıza koduBalancing: Plasma pump delivers from wrong scale (I)
- W185Arıza koduBalancing: Plasma pump delivers from wrong scale (II)
- W190Arıza koduPower failure end
- W192Arıza koduPrime mode: Overload on dialysate scale (CVVHDF)
- W193Arıza koduPrime mode: Overload on SUB scale (CVVHDF)
- W196Arıza koduPrime mode: Overload on sub-scale-pre (HVCVVH)
- W197Arıza koduPrime mode: Overload on sub-scale-post (HVCVVH)