Kodlar
- dAL87Arıza kodu
- dAL88Arıza kodu
- dAL89Arıza kodu
- dAL90Arıza kodu
- dAL91Arıza kodu
- dC6-13Arıza kodu
- dC15-19Arıza kodu
- dC20-24Arıza kodu
- dC25Arıza kodu
- dC26Arıza kodu
- dC28Arıza kodu
- dC29Arıza kodu
- dC30Arıza kodu
- dC31Arıza koduİsteğe bağlı pil takımının mevcut durumunu gösterir. PASS: Pil paketi tamamen şarj oldu. HATA: Pil takımı voltajı düşük
- dC32Arıza kodu
- dC33Arıza kodu
- E01Arıza koduIndoor-remote controller communication trouble (detected at remote controller end)
- E2Arıza kodu
- E03Arıza kodu
- E04Arıza kodu
- E06Arıza kodu
- E07Arıza kodu
- E09Arıza kodu
- E10Arıza kodu
- E11Arıza kodu
- E16Arıza koduToo many indoor units connected / overloading
- E17Arıza kodu
- E18Arıza kodu
- E20Arıza koduDetection of refrigerant piping communication trouble during automatic address setting
- E23Arıza kodu
- E26Arıza kodu
- E31Arıza koduThere is no communication between P.C. boards in inverter box
- F01Arıza koduHeat exchanger temperature sensor (TCJ) has been open / short-circuit
- F02Arıza koduHeat exchanger temperature sensor (TC2) has been open / short-circuit
- F03Arıza koduHeat exchanger temperature sensor (TC1) has been open / short-circuit
- F04Arıza koduOutdoor discharge temperature sensor (TD1) has been open/short-circuited
- F05Arıza koduOutdoor discharge temperature sensor (TD2) has been open/short-circuited
- F06Arıza koduOutdoor heat exchanger liquid side temperature sensors (TE1, TE2, TE3) have been open/ short-circuited
- F07Arıza koduOutdoor liquid temperature sensor (TL1,TL2,TL3) has been open/short-circuited
- F08Arıza kodu
- F09Arıza koduOutdoor heat exchanger gas side temperature sensors (TG1, TG2, TG3) have been open/ short-circuited
- F10Arıza koduAmbient temperature sensor (TA) has been open / short-circuit
- F11Arıza koduDischarge temperature sensor (TF) has been open / short-circuit
- F12Arıza koduOutdoor suction temperature sensor (TS1,TS3) has been open/short-circuited
- F13Arıza koduTemperature sensor built into indoor IPM (TH) has been open/short-circuited
- F15Arıza koduWiring trouble in outdoor temperature sensors (TE1,TL1) has been detected
- F16Arıza koduWiring trouble in outdoor pressure sensors (Pd, Ps) has been detected
- F22Arıza koduOutdoor discharge temperature sensor (TD3) trouble Low pressure sensor (Ps) trouble High pressure sensor (Pd) trouble Outdoor unit pressure sensor trouble Occupancy sensor trouble Indoor unit EEPROM trouble
- F23Arıza koduOutput voltage of low pressure sensor (Ps) is zero