Carrier Aquasnap Tüm modeller arıza kodları
Kodlar
- P-21Arıza kodu
- P-22Arıza kodu
- P-23Arıza kodu
- P-24Arıza kodu
- P-25Arıza kodu
- P-26Arıza kodu
- P-27Arıza kodu
- P-29Arıza kodu
- P-30Arıza koduMaster/Slave communication Failure
- P-32Arıza koduWater pump #1 default
- P-33Arıza koduWater pump #2 default
- P-34Arıza koduCircuit A Reclaim Operation Failure
- P-35Arıza koduCircuit B Reclaim Operation Failure
- P-43Arıza koduLow entering water temperature in heating
- P-97Arıza koduWater Exchanger Temperature Sensors Swapped
- P50Arıza koduFAULT HISTORY - Last 8 faults
- P52Arıza koduDC BUS VOLTAGE - in percent of nominal
- P53Arıza koduMOTOR VOLAGE - in percent of rated output
- P54Arıza koduLOAD - in percent of drives rated output current
- P67Arıza koduMin alarm
- P68Arıza koduMax alarm
- Pr-07Arıza koduCircuit A Reclaim Pumpdown Pressure Transducer
- Pr-08Arıza koduCircuit B Reclaim Pumpdown Pressure Transducer
- R1Arıza kodu
- RH005Arıza koduYer {0}
- RS485Arıza koduTwo-directional high-speed communication using the ModBus over Ethernet network (IP) protocol
- S1Arıza koduX2, aşağıdaki gibidir: ilk şekil X1, ilk basamağa karşılık gelen sayıya ulaşana kadar 1 saniyelik aralıklarla yanıp söner, 2 saniyelik bir duraklamadan sonra, ikinci şekil X2, saniyeye karşılık gelen sayıya ulaşılana kadar tekrar 1 saniyelik aralıklarla yanıp sönmeye başlar (yalnızca iki basamaklı kodlar için). Kalıcı alarm durumu 1 + 1 + 1=3 1 31 LED ile alarm kodu 31 1 saniye boyunca LED kapalı Alarm kodunun tekrar gösterilmesi için uzaktan kumandadaki Eco düğmesine basıncontrol. By pressing the ON/OFF button, the unit is turned off and the alarm code is shown again. To restart the unit, remove the alarm cause and press the ON/OFF button again
- SP14Arıza koduESC ALARM SET
- T051Arıza koduCircuit A, Compressor 1 Failure
- T052Arıza koduCircuit A, Compressor 2 Failure
- T053Arıza koduCircuit A, Compressor 3 Failure
- T055Arıza koduCircuit B, Compressor 1 Failure
- T056Arıza koduCircuit B, Compressor 2 Failure
- T057Arıza koduCircuit B, Compressor 3 Failure
- T062Arıza koduCondenser Leaving Fluid Thermistor Failure
- T063Arıza koduCondenser Entering Fluid Thermistor Failure
- T068Arıza koduCircuit A Return Gas Thermistor Failure
- T069Arıza koduCircuit B Return Gas Thermistor Failure
- T073Arıza koduOutside Air Thermistor Failure
- T074Arıza koduSpace Temperature/Dual Chiller Thermistor Failure
- T077Arıza koduCircuit A Saturated Suction Temperature exceeds Cooler Leaving Fluid Temperature
- T078Arıza koduCircuit B Saturated Suction Temperature exceeds Cooler Leaving Fluid Temperature
- T079Arıza koduLead/Lag LWT Thermistor Failure
- T090Arıza koduCircuit A Discharge Pressure Transducer Failure
- T091Arıza koduCircuit B Discharge Pressure Transducer Failure
- T092Arıza koduCircuit A Suction Pressure Transducer Failure
- T093Arıza koduCircuit B Suction Pressure Transducer Failure
- T094Arıza koduDischarge Gas Thermistor Failure
- T110Arıza koduCircuit A Loss of Charge
- T111Arıza koduCircuit B Loss of Charge