Baxter Tüm modeller arıza kodları
Kodlar
- 32Arıza koduSystem Error 32
- 33Arıza koduSystem Error 33
- AB01Arıza koduDuring antibolus motor has exceeded the step count limit
- AB02Arıza koduDuring antibolus pusher position travel has exceeded the limit
- AB03Arıza koduAntibolus duration has exceeded the limit
- AL01Arıza koduAlarm manager software module has failed
- B0691Arıza koduDirection and Drive Motor Module (DDMM) (Daughter Board)
- B0696Arıza koduRetainer Bracket, Motor
- B6210Arıza koduSyringe size sensor
- B6660Arıza koduSecure sensors unit B6660032
- B8703Arıza koduSyringe barrel sensor cover
- BAR01Arıza koduBarrel sensor is damaged
- BN0360Arıza koduOperator’s Manual Flo-Gard GSP Syringe Infusion Pump
- BS0360Arıza koduService Manual Flo-Gard GSP Syringe Infusion Pump
- BT01Arıza kodu
- BT02Arıza kodu
- BT03Arıza kodu
- BT04Arıza koduThe battery temperature is high (greater than 60°C)
- BT05Arıza koduThe battery charging current is high (greater than 1.5A)
- BT06Arıza koduThe battery discharging current is high (greater than 1.5A)
- BT07Arıza koduThe battery charging current is low (less than 50mA)
- BT09Arıza kodu
- C5Arıza koduRetainer Bracket, Motor
- C7Arıza koduDirection and Drive Motor Module (DDMM) (Daughter Board)
- CN701Arıza koduPANEL LOCK switch is not accepted
- CN851Arıza kodu
- D4Arıza koduPusher lever sensor (D5)
- EE03Arıza koduExternal EEPROM software module has failed
- EV01Arıza koduSoftware Event module has failed
- F3Arıza koduF3 on UIM PCB is blown
- ID01Arıza koduIncorrect drug name or pump ID in EEPROM
- IF01Arıza kodu
- LCD01Arıza koduLCD display software module has failed
- LCD02Arıza koduSoftware graph plotting on display module has failed
- LED01Arıza koduLEDs control software module has failed
- M0Arıza kodupump status is corrupt at set status() _ _
- M1Arıza kodupump status is corrupt at clear status() _ _
- M8Arıza koduEEPROM read after write error in reset event log() _ _
- M9Arıza koduEEPROM read after write error in reset event log() _ _
- N0Arıza koduEEPROM read after write error in log event() _
- N1Arıza koduEEPROM read after write error in log event() _
- N2Arıza koduEEPROM read after write error in reset syserr log() _ _
- N3Arıza koduEEPROM read after write error in reset syserr log() _ _
- N4Arıza koduEEPROM read after write error in log syserr() _
- N5Arıza koduEEPROM read after write error in log syserr() _
- N6Arıza koduchecksum error on get next event() _ _
- N8Arıza koduchecksum error on log syserr() _
- N9Arıza koduchecksum error on get next syserr() _ _
- nce804Arıza koduNuisance 804:34 failure code correction
- of0Arıza koduMeasuring pumped solution in volume delivery accuracy tests