- for72Error codeVerify ground wire is connected on both incoming voltage side and motor side of Intellidrive. Ungrounded Intellidrive, with ground detection With the power disconnected, use an ohmmeter to verify which pipe the Warning LED flashing parameter disabled (will operate for 72 hours Intellidrive’s transducer is connected to. Also verify that the input ground and then fault). wire is at the same potential, e.g., has approximately the same ohm reading. Verify the input ground is connected all the way back to electrical panel
- I1Error codeThe external device detected fault condition External Fault Check external device. and closed the I1 or I2 input
- in3Error codeShorted output Check for any shorts in motor cables. Damaged wire insulation Check motor wire insulation with a megger. Over Current Missing Phase in 3-Phase motor Ohm cable and motor to confirm balanced Ohms. Entered wrong Service Factor Amps Review motor perameters in main menu