Nokia switch All models error codes
Codes
- 9Error codeThere is no valid Ethernet signal detected on the replication Ethernet of the designated SP. Faulted SP
- 91Error codeSP-%c memory threshold alarm cleared
- 93Error codeSP-%c disk space threshold alarm cleared on %s
- 901Error codeIndicates a 1 min threshold has been crossed for SS7 messaging over a link. Call volumes are larger than planned. Equipment or facility faults have caused a large number of releases
- 903Error codeIndicates a 5 min threshold has been crossed for SS7 messaging over a link. Call volumes are larger than planned. Equipment or facility faults have caused a large number of releases
- 905Error codeIndicates a 15 min threshold has been crossed for SS7 messaging over a link. Call volumes are larger than planned. Equipment or facility faults have caused a large number of releases
- 918Error codeMore than %d percent of trunks in TrkGrp %d are OOS. Facilities Faults caused trunks to go OOS or Provisioning has taken trunks OOS
- 919Error codeFacilities faults or provisioning
- 922Error codeISUP ACC Congestion Level. Call volumes are larger than planned. Equipment or facility faults have caused a large number of releases
- 923Error codeCall volumes are larger than planned or Equipment or facility faults have caused a large number of releases
- 926Error codeThis alarm is obsolete. Remote Node Unreachable - ChassisId %d SP-%c. Network
- 928Error codePVCID %s-%d receiving T1 AIS sending AIS on %s. Possible cabling fault, provisioning error or faulted IOM
- 929Error codePVCID %s-%d receiving T1 RAI sending RAI on %s. Possible cabling fault, provisioning error or faulted IOM
- 931Error codeIncorrect Times Ten schema version. Corrupted disk file system or Software or CPU subsystem error
- 932Error codePersistent database Main daemon halted. Corrupted disk file system or Software or CPU subsystem error
- 933Error codePersistent database Main daemon exited. Corrupted disk file system or Software or CPU subsystem error
- 934Error codePersistent database Replication daemon exited. Corrupted disk file system or Software or CPU subsystem error
- 935Error codeSP-%c Persistent database space exhausted. Corrupted disk file system or Software or CPU subsystem error
- 951Error codeIndicates IP connectivity between the switch and the router is broken when using the PNA IOM for IP. Router is down, PNA IOM has faulted or the OC fiber has been removed or is faulty. Check the IOM and OC are in-service. If they are, check the IP configuration, or the ATM PVC configuration to see that it matches the router
- 953Error codeIOM-%d VOIP faulted - cause - %s
- 956Error codeMG overload detected CPU usage %d
- 957Error codeMG overload cleared - total rejected calls during overload %d
- 958Error codeIndicates a software process on the SP is not responding. Software fault on the indicated SP or hardware fault on the front SP module
- 960Error codeSP-%c failover due to IP connectivity fault - SP-%c has %d conns - SP-%c has %d
- 961Error codeSP-%c faulted with status - %s(%d)
- 969Error codeIndicates MGCP cannot connect to DNS server. Faulted voice over packet facilities, equipment at remote endpoint not provisioned or equipment at DNS server faulted
- 971Error codeIndicates a software error. Software or CPU subsystem error or mismatch in software versions between the SPs
- 978Error codeIOM-%d TSU %s Error -%s
- 979Error codeIOM-%d FSU %s Error -%s
- 982Error code%s Device Error
- 983Error codeIndicates there is no input signal on an E1 on a T1 IOM. Possible cabling fault, provisioning error or faulted IOM
- 985Error codeIndicates there is framing cannot be detected on a input signal for an E1 on an E1 IOM. Possible cabling fault, provisioning error or faulted IOM
- 987Error code%s Alarm Indication Signal
- 988Error code%s Alarm Indication Signal cleared
- 989Error code%s Remote Defect Indication
- 990Error code%s Remote Defect Indication cleared
- 991Error code%s Alarm Indication Signal (Tu)
- 992Error code%s Alarm Indication Signal (Tu) cleared
- 993Error code%s Remote Defect Indication (Tu)
- 994Error code%s Remote Failure Indication (Tu) cleared
- 995Error codeIndicates a loss of pointer from the far end tributary unit on an STM1 IOM. Possible cabling fault, provisioning error or faulted IOM
- 997Error codeIndicates the an E1 of an STM interface is not provisioned. Possible cabling fault, provisioning error or faulted IOM
- 999Error codeIndicates there is framing cannot be detected on a input signal for an E1in an STM1. Possible cabling fault, provisioning error or faulted IOM
- BER-1Error codeBackground Block Error Ratio/Percentage (Type 1)
- CRError codeCritical alarms are used to indicate that a severe, service-affecting condition has occurred and that immediate corrective action is imperative, regardless of the time of day or day of the week. An access transport entity (e.g., DLC) must generate a critical alarm if more than 128 access lines are out of service
- DLP-507Error codeReplace a Fan Shelf
- DLP-515Error codeReplace a Faulted DS1 or DS3 IOM
- DLP-535Error codeReplace a Module, Fan or Fan Filter
- DLP-568Error codeRetrieve Alarms or Conditions
- DLP-609Error codeRetrieve or Delete Alarm Queue