Mitsubishi lazer kesim makinesi All models error codes
Codes
- H7Error codeCharacter error
- H70Error codeH0000 to HFFFF: Output current (hexadecimal) Increment 0.01 A (FR-F820-02330(55K) or lower, FR-F840-01160(55K) or lower) Increment 0.1 A (FR-F820-03160(75K) or higher, FR-F840-01800(75K) or higher)
- H71Error codeH0000 to HFFFF: Output voltage (hexadecimal) in 0.1 V increments
- H74Error codeH0000 to HFFFF: Two latest fault records b15 b8 b7 b0 H74 Second fault in past Latest fault H75 Fourth fault in past Third fault in past H76 Sixth fault in past Fifth fault in past H77 Eighth fault in past Seventh fault in past Fault record display example (instruction code H74) With the read data H30A0 (Last fault : THT) (Present fault : OPT) b15 b8b7 b0 0 0 1 1 0 0 0 0 1 0 1 0 0 0 0 0 Last fault Present fault (H30) (HA0) (Refer to page 533 for details on fault record read data.)
- H79Error codeb0: RUN (Inverter running) b1: During forward rotation b2: During reverse rotation b3: SU (Up to frequency) b4: OL (Overload warning) b5: IPF (iInstantaneous power failure/ undervoltage) b6: FU (Output frequency detection ) b7: ABC1 (Fault) b8: ABC2 (-) b9: Safety monitor output b10 to b14: - b15: Fault occurrence
- HF4Error codeH9696: Faults history batch clear
- I1Error codeR/L1, S/L2, T/L3 line current
- I2Error codeU, V and W line currents
- L1Error codeInrush current limit circuit
- L2Error code
- L3Error code
- M330Error codeC8 (930)
- M331Error codeC9 (930)
- M332Error codeC10 (931)
- M333Error codeC11 (931)
- MC1Error code
- MC2Error code
- MC3Error codeBetween inverter output and motor
- mm2Error codeBlade terminal model With insulation sleeve Without insulation sleeve For UL wire
- N002Error code0.1 to 999.8 s
- N026Error code0.1 to 999.8 s
- N041Error code0.1 to 999.8 s
- N500Error code1300 to 1343, 1350 to 1359
- Pf1Error codeCalculate after measuring power supply voltage, power supply side current and power supply side power. Pf1 = ----------P ----1----------100 % 3V1I1
- Pr96Error codeApprox. 25 to 120 s (The time depends on the inverter capacity and motor type.)
- R1Error codeConnected to the AC power supply terminals R/L1 and S/L2. To retain the fault display and fault output, or to use a high power factor converter (FR- HC2) or a power regeneration common converter (FR-CV), remove the jumpers across terminals R/L1 and R1/L11 and across S/L2 and S1/L21, and supply external power to these terminals. The power capacity necessary when separate power is supplied from R1/ L11 and S1/L21 differs according to the inverter capacity. FR-F820-00630(15K) or lower, FR-F840-00380(18.5K) or lower 60 VA FR-F820-00770(18.5K) or higher, FR-F840-00470(22K) or higher 80 VA
- RS-485Error codeWith the PU connector, communication can be made through RS-485. (For connection on a 1:1 basis only) Conforming standard: EIA-485 (RS-485) Transmission format: Multidrop link Communication speed: 4800 to 115200 bps Wiring length: 500 m
- V1Error codeAcross R/L1 and S/L2, S/L2 and T/L3, T/L3 and R/L1
- V2Error codeAcross U and V, V and W, and W and U
- X95Error codeSet "95" and "96" in any of Pr.180 to Pr.189
- z6HError codeCharacteristic when electron function for motor protection (When Pr.9 setting is 0(A))