Ghibli endüstriyel süpürge All models error codes
Codes
- A2Error codeNot an actual alarm-
- U-00Error codeCommunication error- In order to properly communicate the inverter needs to have the required power to the inverter. It will also digitally communicate with the inverter
- U-09Error codeInverter parameters are not recognized- Inverter has to be able to talk with the microprocessor. Loading parameters allows this communication
- U-39Error codeInverter fault- Fault in inverters internal control
- U-41Error codeInverter to motor fault - A fault in one of the three inverter/ motor output phases
- U-50Error codeShort detected in the motor windings- A short in the motor or motor winding. This could be a short phase to phase, phase to housing, or phase to klixon
- U-56Error code
- UA11Error codeOpen phase error- Loss of motor phase during operation Motor not connected- Motor disconnected during operation
- UA13Error codeADC hardware error- Inverter has failed Electronic circuit error- Internal component of the inverter is damaged Inrush current failure- Inverter has failed
- UA14Error codeOver current diversion- Inverter is detecting an over current situation
- UA16Error codeInverter overcurrent error-
- UA17Error codeInverter overload error- Excessive motor consumption Motor over temperature error Motor over temperature
- UA18Error codeUnder voltage on the DC buss Low voltage on the DC buss Error in V buss sensor- Voltage error
- UA19Error codeInverter over voltage- Excessive voltage on the inverter’s DC buss
- UA20Error codeInverter general error
- UA21Error codeInverter over heating error- Inverter power circuit over heated
- UA22Error codeVoltage error- Supply voltage is out of range Motor system error- Inverter’s microprocessor is not functioning properly
- UA23Error codeSpeed limitation error- Compatibility error between the microprocessor and the inverter
- UA25Error codeInverter communication error-
- UA27Error codeStartup fail error- Machine did not initialize when power was turned on
- UA29Error codeOvercurrent diversion error- Internal permanent magnet issue on the motor I2T overcurrent error Inverter error
- UA39Error codeInverter fan error- Fault with the inverter’s fan
- V-10Error codeInput inverter voltage out of range- Incorrect incoming voltage to inverter
- V-11Error codeUnbalanced amperage draw- The inverter detects an unbalanced amperage draw in between the motor and inverter
- V-15Error codeLow inverter voltage- The inverter is detecting a lower than normal voltage reading