Skip to content
RemFixitSearch fault code

Error code

Ghibli endüstriyel süpürge All models code U-09

No approved translation for this record yet; showing the original text.

Meaning

Inverter parameters are not recognized- Inverter has to be able to talk with the microprocessor. Loading parameters allows this communication

Member details

Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.

View details as a member

Possible causes

1. Download and verify inverter parameters. The door has to be closed in order to download parameters. 2. Verify the integrity of the motor discharge resistor and the Earth ground. Please refer to ST-112R* 3. Verify power at the inverter. Check fuses and inverter relay. 4. Verify the integrity of the communication wire harness and clean the contacts points with contact cleaner. Make sure wires are properly pushed into the connector. 5. Possible bad inverter

Solution

Solution steps are available to members and are not shown on this page. Answer the questions to open the solution.

Remote technician support

Get help from a technician over a video call.