- n8-89Error code
- n8-90Error code
- n8-91Error codeSets the amount of pull-in current that flows through the motor while operating at constant speed. Set as a percentage of the motor rated current (E5-03). Increase this setting if hunting occurs at constant speed
- o1-01Error codeSwitches the display after the power has been turned on. When using an LED operator, pressing the up arrow key will display the following data: frequency reference → rotational direction → output frequency → output current → output voltage → U1-oo. (This is done by entering the 1oo part of U1-oo. Certain monitors are not available in some control modes.)
- o1-02Error codeSelects the information that is displayed when the power is turned on. 1: Frequency Reference (U1-01) 2: Forward/Reverse 3: Output Frequency (U1-02) 4: Output Current (U1-03) 5: User Monitor (set by o1-01)
- o1-03Error codeSets the units to display the frequency reference and output frequency. 0: Hz 1: % (100% = E1-04) 2: r/min (enter the number of motor poles into E2-04/E4-04/ E5-04) 3: User defined by parameters o1-10 and o1-11
- o2-03ParameterAllows storing of parameter settings as a User Initialization Selection. 0: Saved/Not set 1: Set Defaults - Saves current parameter settings as user default settings. 2: Clear All - Clears the currently saved user settings. After saving the user parameter set value, the items of 1110 (User Parameter Initialize) are displayed in A1-03 (User Parameter Default Value)
- o2-06Error codeSets drive action when the digital operator is removed in LOCAL mode or with b1-02 = 0. 0: The drive will continue operation 1: The drive will trigger a fault (oPr) and the motor will coast to stop
- o2-07Error codeMotor Direction at Power Up when Using Operator
- o4-03Error codeSets the value of the fan operation time monitor U4-03 in units of 10 h. <6>
- o4-13Error codeMotor r/min Reset
- oH1Error code(Drive Overheat)
- oL1Error code(Motor Overload)
- oL2Error code150% of drive rated Heavy Duty current for 60 s
- oPE02Error codeNote: Other errors are given precedence over oPE02 when multiple errors occur at the same time
- oPE03Error codeA contradictory setting is assigned to multi-function contact inputs H1-01 through to H1-06. • The same function is assigned to two inputs. (this excludes “External fault” and “Not used”) • Input functions which require the setting of other input functions were set alone. • Input functions that are not allowed to be used simultaneously have been set
- S4Error codeFix the cause of the fault and reset via Fault Reset Digital Input S4
- SW1Error codewitches analog input A2 between voltage and current input
- T1Error codeDrive output
- T1-00Error codeSelects which set of motor parameters are used and set during Auto-Tuning. If Motor 2 selection (H1-oo = 16) is not selected, this parameter will not be displayed. 1: Motor 1 (sets E1-oo, E2-oo) 2: Motor 2 (sets E3-oo, E4-oo. This selection is not displayed if motor 2 has not been selected.)
- T1-01Error codePerform when setting the drive to operate in Open Loop Vector control. The motor must be able to rotate without V load during the tuning process in order to achieve a high accuracy
- T1-02Error codeMotor output and motor-rated current settings (T1-02 and T1-04) do not match
- T1-03Error codeSets the motor rated voltage in volts (V)
- T1-04Error code• The motor line-to-line resistance and the motor-rated current are not consistent with one another. • The correct current rating printed on the nameplate was not entered into T1-04
- T1-05Error codeBase frequency and base motor rotations (T1-05 and T1-07) do not match
- T1-06Error codeSets the number of motor poles
- T1-07Error codeSets the base speed of the motor in revolutions per minute r/min (RPM)
- T1-11Error codeProvides the iron loss for determining the Energy Saving coefficient. The value set to E2-10 (motor iron loss) when the power is cycled. If T1-02 is changed, an initial value valid for the selected capacity will be shown
- T3Error codeThe current is too low
- to1Error codeThe drive prohibits reverse rotation
- to40Error code7 (Swing PWM 1)
- U1-03Error codeDisplays the output current
- U1-05Error codeDisplays the motor speed feedback. Display units are determined by o1-03
- U1-06Error codeDisplays the output voltage
- U1-07Error codeDisplays the DC bus voltage
- U1-09Error codeTorque Reference (% of motor rated torque)
- U1-11Error codeDisplays the output terminal status. Multi-Function Digital Output (fault) (terminal MA/MB-MC) Multi-Function Digital Output 1 (terminal P1) enabled Multi-Function Digital Output 2 (terminal P2) enabled
- U1-12Error codeVerifies the drive operation status. During run During zero-speed During REV During fault reset signal input During speed agree Drive ready During alarm detection During fault detection
- U1-18Error codeNote: Use U1-18 to find parameters set outside of the specified setting range. Other errors are given precedence over oPE08 when multiple errors occur simultaneously
- U1-19Error codeDisplays the contents of a MEMOBUS/Modbus error. CRC Error Data Length Error Not Used Parity Error Overrun Error Framing Error Timed Out Not Used
- U2Error codeFault Trace...........................................................................................................................243
- U2-01Error codeDisplays the current fault
- U2-02Error codeDisplays the previous fault
- U2-03Error codeDisplays the frequency reference at the previous fault
- U2-04Error codeDisplays the output frequency at the previous fault
- U2-05Error codeDisplays the output current at the previous fault
- U2-06Error codeDisplays the motor speed at the previous fault
- U2-07Error codeDisplays the output voltage at the previous fault
- U2-08Error codeDisplays the DC bus voltage at the previous fault
- U2-09Error codeDisplays the output power at the previous fault