Yaskawa VZA error codes
Codes
- 20-2Error codeHarici hata; Giriş modu: N.A. kontak/N.K. kontak, Algılama modu: Normal/çalışma sırasında
- A1-03Error codeInicializar parámetros
- b1-01Error code0:Operatör - d1- değerleri 1:Analog giriş A1 veya A2 2:Seri Haberleşme - RS-422/485 3:Opsiyon kartı 4:Puls Giriş (Terminal RP)
- b1-02Error code0:Operatör - RUN ve STOP tuşları 1:Terminaller - Dijital Girişler 2:Seri Haberleşme - RS-422/485 3:Opsiyon kartı bağlı
- b2-02Error codeSets the DC Injection Braking current as a percentage of the drive rated current. In OLV the DC excitation current is determined by E2-03
- CPF00Error code* The following faults are not recorded in the error log: CPF00, 01, 02, 03, UV1, and UV2
- E1-01Error codeInput Voltage
- E1-04Error codeFor a linear V/f characteristics, set the same values for E1-07 and E1-09. In this case, the set- ting for E1-08 will be disre- garded. Ensure that the four frequencies are set according to these rules or OPE10 fault will occur: E1-04 ≥ E1-06 ≥ E1-07 ≥ E1-09
- E1-05Error codeMax. Out- put Voltage
- E1-07Error codeTension de sortie (E1-05) (E1-13) (E1-08) (E1-10) (E1-09) (E1-07) (E1-06) (E1-04) Fréquence de sortie
- E1-08Error codeOutput voltage (E1-05) (E1-13) (E1-08) (E1-10) (E1-09) (E1-07) (E1-06) (E1-04) Output frequency
- E1-10Error codeTensión de salida mínima
- E1-13Error codeBase Voltage
- E2-01Error codeMotornenn- strom
- E2-02Error codeMotor rated slip in hertz (Hz). Automatically set by Rotational Auto-Tuning
- E2-03Error codeMagnetizing current in Ampere. Automatically set by Rotational Auto-Tuning
- E2-04Error codeNumber of motor poles. Auto- matically set by Auto-Tuning
- E2-05Error codeSets the phase-to-phase motor resistance in ohms. Automatically set by Auto-Tuning
- E2-06Error codeSets the voltage drop due to motor leakage inductance as a percentage of motor rated volt- age. Automatically set by Auto-Tuning
- H1Error codeConectar la carga, poner en marcha el motor y comprobar el funcionamiento
- H4-02Error codeSets terminal AM output voltage equal to 100% monitor value
- L1Error codeZum Ansch Eingang Leistungs- Bei Antrieb kreis-Spannungsver- den nur die sorgung verwendet)
- L1-01Error codeSets the motor overload protec- tion. 0:Disabled 1:Standard fan cooled motor 2:Standard blower cooled motor 3:Vector motor
- L1-02Error codeSets the motor overload protec- tion time in min. Normally no change is necessary
- L1AError codePannello o p
- L1EError codePanneau o
- L3-01Error code0:Disabled - Motor accelerates at active acceleration rate and may stall with too heavy load or too short accel time. 1:General Purpose - Hold acceleration when current is above L3-02. 2:Intelligent - Acceleration in the shortest possible time
- L3-02Error codeSets the current level for stall prevention during acceleration
- L3-04Error code0:Disabled - Deceleration as set. OV might occur. 1:General Purpose - Decelera- tion is hold if DC bus voltage rises high
- L3-05Error code0:Disabled - Motor stall or overload might occur. 1:Decel Time 1 - Reduce speed using C1-02
- L3-06Error codeSets the current level at which stall prevention during run starts to operate
- oPE05Error code• Der Parameter zur Auswahl der START- Befehlsquelle (b1-02) oder zur Auswahl der Frequenzsollwertquelle (b1-01) wurde auf 3 eingestellt, es wurde jedoch keine Optionskarte installiert. • Die Frequenzsollwertquelle ist auf Impulsein- gang eingestellt, aber H6-01 ist nicht 0
- SW1Error codeSchaltet Analogeingang A2 zwischen Spannungs- und Stromeingang um
- SW2Error codeAktiviert oder deaktiviert den Abschlusswiderstand des internen RS422/485-Kommunikations-Ports
- SW3Error codeDient zur Auswahl von PNP- oder NPN-Modus (werkseitig eingestellt) für die digitalen Eingänge (bei PNP ist eine externe 24 V DC-Spannungsversorgung erforderlich)
- T1Error codeDrive output Connects to
- T1-01Error codeAuswahl der Autotuning- Betriebsart
- T1-02Error codeSets the motor rated power (kW)
- T1-03Error codeSets the motor rated voltage (V)
- T1-04Error codeSets the motor rated current (A)
- T1-05Error codeSets the motor base frequency (Hz)
- T1-06Error codeSets the number of motor poles
- T1-07Error codeSets the motor base speed (RPM)
- T1-11Error codeMotor-Eisen- verlust
- U1-03Error codeOutput Current (A)
- U1-05Error codeMotor Speed (Hz)
- U1-06Error codeOutput Voltage Reference (Vac)
- U1-07Error codeDC Bus Voltage (Vdc)
- U1-09Error codeTorque Reference (% of motor rated torque)
- U1-12Error codeDrive Status U1-12=00000000 1: During run 1: During zero-speed 1: During REV 1: During fault reset signal input 1: During speed agree 1: Drive ready 1: During alarm detection 1: During fault detection