Yaskawa CIMR-F7U error codes
Codes
- b1-02Error codeRun Command Selection Run Source
- b3Error codeF6 Communications Option Setup
- b8Error codeH5 Serial Communications Setup
- b8-03Error codeEnergy Saving Control Filter Time Constant Energy Saving F.T
- b8-04Error codeEnergy Saving Coefficient Value Energy Save COEF
- C1Error codeL1 Motor Overload
- C5Error codeL5 Fault Restart
- C6-01Error codeRated Output Current
- CH1Error code
- CPF00Error codeOperator Communication Fault Transmission between the Drive and the Digital Operator was not established within 5 seconds after supplying power
- CPF01Error codeOperator Communication Fault After communication started with the Digital Operator, communication stopped for 2 seconds or more
- CPF02Error codeBaseblock Circuit Fault Baseblock circuit fault at power-up
- CPF03Error codeEEPROM Fault Check sum was not valid
- CPF04Error codeCPU Internal A/D Converter Fault
- CPF05Error codeExternal A/D Converter Fault
- CPF06Error codeOption Board Connection Error
- CPF07Error codeASIC Internal RAM Fault
- CPF08Error codeWatchdog Timer Fault
- CPF09Error codeCPU-ASIC Mutual Diagnosis Fault
- CPF10Error codeASIC Version Fault
- CPF20Error codeOption Card Fault
- CPF21Error codeSelf-diagnosis Fault of Option Board
- CPF22Error codeOption Board Code Number Fault
- CPF23Error codeOption Board Interconnection Fault
- D1Error code1. 2. Place the positive (red) meter lead on terminal R/L1. Place the negative (black) meter lead on terminal ⊕ 1. Expected reading is about 0.5Vdc. 3. Place the positive (red) meter lead on terminal S/L2. Place the negative (black) meter lead on terminal ⊕ 1. Expected reading is about 0.5Vdc. 4. Place the positive (red) meter lead on terminal T/L3. Place the negative (black) meter lead on terminal ⊕ 1. Expected reading is about 0.5Vdc. 5. Place the positive (red) meter lead on terminal R/L1. Place the negative (black) meter lead on terminal (-). Expected reading is OL displayed. 6. Place the positive (red) meter lead on terminal S/L2. Place the negative (black) meter lead on terminal (-). Expected reading is OL displayed. 7. Place the positive (red) meter lead on terminal T/L3. Place the negative (black) meter lead on terminal (-). Expected reading is OL displayed. 8. Place the positive (red) meter lead on terminal (-). Place the negative (black) meter lead on terminal R/L1. Expected reading is about 0.5Vdc. 9. Place the positive (red) met
- E1Error code01 Input Voltage Setting ....................................5-12
- E1-01Error codeOvervoltage, braking resistor turn-on, stall prevention, etc.)
- E1-05Error codeMaximum Output Voltage
- E1-06Error codeMax. Voltage Frequency
- E1-08Error codeMid. Output Voltage
- E1-13Error codeBase Voltage
- E2Error code01 Motor Rated Current .....................................5-20
- E2-06Error codeMotor Leakage Inductance Leak Inductance
- E2-07Error codeMotor Iron-core Saturation Coefficient 1 Saturation Comp 1
- E2-08Error codeMotor Iron-core Saturation Coefficient 2 Saturation Comp 2
- E2-10Error codeMotor Iron Loss for Torque Compensation Tcomp Iron Loss
- E2-11Error codeSet to the motor rated power in KW. This value is automatically set during Auto-Tuning
- E2-12Error codeMotor Iron-Core Saturation Coefficient 3 Saturation Comp 3
- EF0Error codeOption Board External Fault
- EF3Error codeExternal Fault at Terminal S3 - S8 Detected when terminals S3 - S8 (H1-01 to H1-06) are programmed for external fault function that stops the Drive using ramp to stop, coast to stop, or fast stop
- Er-01Error codeMotor Data Fault
- Er-02Error codeAlarm
- Er-05Error codeNo-Load Current Fault
- Er-08Error codeRated Slip Fault
- Er-09Error codeAcceleration Fault Detected only for rotational Auto- Tuning
- Er-11Error codeMotor Speed Fault Detected only for rotational Auto- Tuning
- Er-12Error codeCurrent Detection Fault
- Er-13Error codeLeakage Inductance Fault
- F1-02Error codeOperation Selection at PG Open Circuit (PGO) PG Fdbk Loss Sel
- F1-03Error codeOperation Selection at Overspeed (OS) PG Overspeed Sel