Toshiba Estia All models error codes
Codes
- 0Error codeON (Using)
- 0AError codeAnti bacteria set temperature
- 0BError codeMixing valve position
- 0CError codeMixing Valve operation time
- 0dError codeTC sensor open or short circuit
- 0EError codeLow pressure (Ps) × 1/10
- 0FError codeHeat pump operation for hot water supply permitted / not permitted
- 01Error codeTarget water temperature for Zone1
- 1Error code• The qualified installer is a person who installs, maintains, relocates and removes the Air to Water Heat Pump made by Toshiba Carrier Air-conditioning Europe Sp. z o.o.. z o.o. or, alternatively, he or she has been instructed in such operations by an individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge related to these operations. • The qualified installer who is allowed to do the electrical work involved in installation, relocation and removal has the qualifications pertaining to this electrical work as stipulated by the local laws and regulations, and he or she is a person who has been trained in matters relating to electrical work on the Air to Water Heat Pump made by Toshiba Carrier Air-conditioning Europe Sp. z o.o. or, alternatively, he or she has been instructed in such matters by an individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge related to this work. • The qualified installer who is allowed to do the refrigerant handling and p
- 1AError codeOutdoor fan motor problem
- 1bError codeTE sensor fault
- 1CError codeCompressor drive circuit
- 1dError codeCompressor locked rotor current protection
- 1EError codeCompressor - high discharge temperature
- 1FError codeCompressor current remains too high - after current release
- 02Error codeRoom temperature correction (at heating)
- 2Error codeOutdoor fan motor
- 2BError codeOutside temperature T3
- 2CError codeSetting temperature A at T0
- 2DError codeSetting temperature B at T1
- 2EError codeSetting temperature C at T2 (= 0°C)
- 2FError codeSetting temperature D at T3
- 03Error codeRoom temperature correction (at heating)
- 3Error codeThe “Stop” operation on the remote controller will not stop the circulation pump. (The same for hot water supply, heating and cooling)
- 04Error codeIndoor to outdoor communication (includes compressor thermostat)
- 05Error codeIndoor to outdoor communication
- 06Error codeWater inlet temperature (TWI)
- 07Error codeIndoor to outdoor communication (includes compressor thermostat)
- 08Error codeIndoor heat exchanger changes temperature - but in wrong direction
- 09Error codeIndoor fan low speed, no outdoor unitoperation
- 10Error codeFloor inlet temperature sensor (TFI sensor)
- 11Error codeIndoor fan motor problem
- 12Error codeIndoor PCB problem
- 13Error codePulse motor valve (PMV) coil INJ
- 14Error codeInverter low voltage or short circuit protection
- 15Error codeMax temperature
- 16Error codeCompressor position circuit
- 17Error codeCompressor current detected during off-cycle
- 18Error codeTE or TS sensor open or short circuit
- 19Error codeTd sensor open or short circuit
- 20Error codeLow Pressure Trip
- 21Error codeHigh Pressure Trip
- 22Error codePriority mode switch temperature
- 23Error codeBoiler-heat pump switching temperature
- 24Error codeOutside air correction start temperature for hot water supply*3
- 25Error codeOutside air correction temperature for hot water supply*3
- 26Error codeNight setback setting Temperature width
- 27Error codeSet temperature shift with heating set to auto
- 28Error codeUsed to activate system auto restart after power failure. 0 = auto restart de-activated 1 = auto restart activated
- 29Error codeOutside temperature T1