Profilo pos cihazı All models error codes
Codes
- 00Error codeInternal RAM memory error
- 0-3Error code4-** Grenzen/Warnungen
- 01Error codeInternal ROM memory error
- 02Error codeSerious internal EEPROM memory error
- 2-2Error code2-20 Bremse öffnen bei Motorstrom
- 04Error codeThe motor cable or the encoder cable is damaged
- 05Error codeAmbient temperature measurement is wrong
- 09Error codeSet to “00” if no monitoring of Presence impulse sensors is required or if no presence impulse sensors are installed
- 10Error codeInternal register error
- 11Error codeInternal program error
- 12Error codeThe tension wheel lock can only work in one opening direc- tion, CW and cannot be used in CCW
- 13Error codeAdjustment of the force used to keep the door in closed position (ND motor max 30 N, HD and DD motor max 60 N). Unit N
- 14Error codeThe lock is defective
- 14-8Error code13-99 Warnung Zustandswort 14-80 Ext. 24 VDC für Option 14-** Sonderfunktionen 14-88 Optionsdatenspeicher 14-0* IGBT-Ansteuerung 14-89 Optionserkennung
- 16Error codeThedutycycleofthedooristoohighforthecurrent Speed settings and Hold Open Time
- 17Error codeIf the escape route is in the direction of the outer sensor it is a demand to have outer impulse monitored according to EN 16005 or DIN 18650. When outer impulse monitoring is selected C-switch is disabled
- 18Error codeInternal write EEPROM memory error. This error mainly occurs when it is impossible to change a configuration parameter
- 20Error codeThe control unit does not get a test answer from the fire alarm
- 21Error codeThe battery voltage drops due to low capacity dur- ing EEU test
- 25Error codeThe battery is disconnected, short circuited or the internal thermal fuse in the battery is defective. The charging current is out of specification
- 27Error codeThe LDB or LDE lock is defective
- 29Error codeSetto“00”ifnomonitoringofSidePresenceimpulsesensors is required or if no Side Presence impulse sensors are in- stalled
- 31Error code2-wire monitoring is used when a sensor has separate monitoring inputs for both presence and impulse field. If 2-wire monitoring and inner/outer impulse monitoring areselected,theC-Switchfunctionisswitchedtoinner/outer impulsemonitoring(seeparameters16and17onpage69)
- 33Error codeSerious internal programming error
- 34-7Error code34-70 MCO Alarmwort 1
- 35Error codeThe internal link voltage measurement is wrong
- 36Error codeThe door will close on fire impulse or power failure
- 38Error codeWhen this parameter is set to On (01), with a 24V (UPS) battery the operator will continue its normal operation in case of mains power failure. Monitoring will be made if parameter 10 is set to Convenience Monitoring (01). Not approved in escape routes!
- 46Error codeInternal error in the OMS Standard
- 47Error codeCorrupted communication with the OMS when se- lecting operation mode
- 49Error codeThe force applied from the operator to the door leaf during opening.Seealsoparameters50ClosingMaxForce,64Power Supply Type, and 71 Max Motor Power. The lowest value adjusted in parameters above will be used. Normal Duty: Max force 190 N. Heavy Duty: Max force 190 N. Extra Heavy Duty: 230 N. Unit N x10
- 50Error codeThe force applied from the operator to the door leaf during closing. See also parameters 49 Opening Max Force, 64 Power Supply Type, and 71 Max Motor Power. The lowest value adjusted in parameters above will be used. Normal Duty: Max force 190 N. Heavy Duty: Max force 190 N. Extra Heavy Duty: 230 N. Unit N x10
- 51Error codeWhen this parameter is set to On (01) the motor will in op- eration mode selections OFF or EXIT try to close the door withtheforceselectedbyparameter50“ClosingMaxForce”, if someone tries to open it manually. Push & Close is also known as “poor man’s lock”
- 54Error codeThe external bus is malfunctioning
- 64Error code50 / 150 / 75 W power supply. The power supply selected to theoperatordependsonthedesiredperformancelevel.See also parameters 49 Opening Max Force, 50 Closing Max Force, and 71 Max Motor Power. The lowest value adjusted in parameters above will be used
- 65Error codeThe electromechanical lock will never lock in Exit mode se- lection even if parameter 44 is set to On (01). The (+) 24 V DC to accessories like sensors is turned off when the mode selector is in Off and the door is closed. Motor power is lim- ited to 75 W even if parameter 71 is set to a higher value
- 71Error codeThe max amount of power the motor can be supplied with. See also parameters 49 Opening Max Force, 50 Closing Max Force, and 64 Power Supply Type. The lowest value adjusted in parameters above will be used. Unit W x 10
- 111Error codeAdded error E3:46
- 112Error codeAdded error E6:47
- 200-240Error codeBei Höhen über 3000 m wenden Sie sich bezüglich der PELV (Schutzkleinspannung - Protective extra low voltage) an Danfoss
- 256-259Error codeDie EEPROM-Daten der Leistungskarte sind defekt oder zu alt. Ersetzen Sie die Leistungskarte
- 380-500Error codeBei Höhen über 3000 m wenden Sie sich bezüglich der PELV (Schutzkleinspannung - Protective extra low voltage) an Danfoss
- 512-519Error codeInterner Fehler. Wenden Sie sich an Ihren Danfoss - Lieferanten oder an die Service-Abteilung von Danfoss
- 525-690Error codeBei Höhen über 2000 m wenden Sie sich bezüglich der PELV (Schutzkleinspannung - Protective extra low voltage) an Danfoss
- A0Error codeEscape Route Motor Configuration. 1-motor(01) / 2-motor(02)
- A1Error codeParameter 0-21 Displayzeile 1.2
- B4Error codeAlarm Log
- B467Error codeBack Cancel On OK Info Warn. Alarm
- b683Error codeParameter 6-10 Terminal 53 Low Voltage
- b926Error codeParameter 6-10 Terminal 53 Low Voltage