- 4Error codeVoltage (terminal AM)
- 5Error codeVoltage (terminal AM)
- 0008Error codeInverter ND rated current (A)
- 99Error codeLower limit fault detection
- 112Error codeBrake transistor alarm detection
- 128Error codeOutput side earth (ground) fault overcurrent
- 161Error codeCommunication option fault
- 164Error codeUser definition error by the PLC function
- 176Error codeParameter storage device fault (control circuit board) PU disconnection
- 179Error codeParameter storage device fault (main circuit board)
- 192Error codeCPU fault
- 196Error codeAbnormal output current detection
- 197Error codeInrush current limit circuit fault
- 201Error codeSafety circuit fault
- 230Error codePID signal fault
- 232Error codeBoard combination fault
- 241Error codeOption fault
- 245Error codeCPU fault
- 250Error codeInverter output fault Opposite rotation
- 253Error codedeceleration fault Internal circuit fault
- 2020Error codeIB(NA)-0600874ENG-B
- A702Error code0.1 to 30 s
- A800Error codeFR-A800 series inverter with built-in CC-Link IE Field Network communication function
- C8Error codeCurrent output bias signal
- C9Error codeCurrent output bias current
- C10Error codeCurrent output gain signal
- C11Error codeCurrent output gain current
- DU08Error codeOutput terminal operation
- E800Error codeSafety communication model (Ethernet + SIL3/PLe functional safety)
- een480Error codeInput voltage mode selection
- G300Error code10 to 12
- H100Error codeCooling fan operation selection
- H106Error codeCooling fan operation selection during the test operation
- H301Error code1 to 10
- H500Error code0.1 to 400%*1
- HA0Error codeOption fault
- HE6Error codeEthernet communication fault
- HP2Error code• Start signal for the point table positioning has turned ON without completing the home position return. • The Proximity dog signal is turned OFF during transition from the home position return speed to the creep speed when home position return is performed in the dog type or dog type back end reference. • The position command is given for the motor to reach the post-dog travel distance during transition from the home position return speed to the creep speed when home position return is performed in the count type. • The position command is given for the motor to reach the total of the post-dog travel distance and home position shift distance during deceleration from the creep speed after the Proximity dog signal is turned OFF in the dog type back end reference. • The speed did not reach the creep speed in the count type with front end reference
- I1Error codeR/L1, S/L2, T/L3 line current*3
- I2Error codeLine current at U, V, and W
- L2Error code
- L3Error code
- MC1Error code
- MC2Error code
- MC3Error codeBetween inverter output side and motor
- mm2Error codeBlade terminal part No
- N500Error code1300 to 1343, 1350 to 1359
- ON84Error codeMotor rot
- R1Error codeConnected to the AC power supply terminals R/L1 and S/L2. To retain the fault display and fault output, or to use the high power factor converter (FR-HC2), multifunction regeneration converter (FR-XC)*1, or power regeneration common converter (FR-CV), remove the jumpers across terminals R/L1 and R1/L11 and across S/L2 and S1/ L21, and supply external power to these terminals. The power capacity necessary when separate power is supplied from R1/L11 and S1/L21 differs according to the inverter capacity. FR-A820-00630(11K) or lower, FR-A840-00380(15K) or lower: 60 VA FR-A820-00770(15K) or higher, FR-A840-00470(18.5K) or higher: 80 VA