Miele buharlı ütü All models error codes
Codes
- F4110Error codefault check sum Service setting
- F4111Error codefault check sum language
- F4112Error codefault check sum input/output-allocation
- F4113Error codeFAULT CS SYSTEM COMPONENT
- F4114Error code_ _ fault check sum programme memory
- F4115Error codefault check sum Block memory
- F4116Error codefault check sum mashine history
- F4117Error codefault check sum operation data
- F4118Error codefault check sum faults statistic
- F4119Error codefault check sum operation fault
- F4120Error codeFAULT CS DRYER LOW PRESSURE TABLE _ _ _
- F4121Error codefault check sum Standard programme
- F4122Error codefault check sum Standard block
- F4123Error codefault Backup-matching
- F4124Error codefault motor without rotation
- F4125Error codetime overrun (Timeout) in communication between control ELP 230 and frequency converter EFU 230
- F4126Error codefault drive Tacho
- F4127Error codefault drive Tacho after safety time
- F4128Error codefault drive Tacho in programme stop
- F4129Error codefault drive Tacho in programme stop
- F4130Error codefault drive FU-safety brunt
- F4131Error codefault drive Motor klixon
- F4132Error codeFAULT POSITION NOT ADJUSTED
- F4133Error code_ _ _ FAULT POSITION ADJUSTED
- F4134Error code_ _ fault imbalance
- F4135Error codefault imbalance switch
- F4136Error codefault heating system NTC1
- F4137Error codefault heating system NTC1 Desinfection
- F4138Error codefault heating system TGS a contact
- F4141Error codeFAULT HEATING _ SYSTEM TGS DURING HEATING PHASE
- F4142Error code_ _ _ FAULT HEATING SYSTEM TGS MEMORY
- F4143Error code_ _ _ FAULT THERMOSTOP
- F4144Error code_ switch door lock 2F6/6 does not switch or motorklixon F3 has tripped
- F4145Error codeFAULT DOOR LOCK RELEASE
- F4146Error code_ _ FAULT DOOR LOCK DOOR OPEN
- F4147Error code_ _ _ FAULT DOOR LOCK DOOR CLOSE
- F4148Error code_ _ _ FAULT DOOR RELEASE SIGNAL
- F4149Error code_ fault Notentriegelung door open
- F4150Error codeFAULT SAFETY LOCK DOOR CLOSED
- F4153Error codeAnalog pressure sensor recognize overflow level or is faulty
- F4154Error codefault drainage
- F4155Error codefault drainage spin
- F4156Error codesafety pilot notifies a fault (F10, exit 3)
- F4159Error codefault check dispenser system
- F4160Error codeUntil ID 846: level switch B1/1, contact 1-3, when dispenser open. From ID 1000: electric connector on dispenser module (plug 40X GND-IN 7 defect)
- F4164Error codeAnaloger-pressure sensor on ELP 230 defect
- F4165Error codeInterruption plug EB 230 65X, to ELP 230 30X. Or EB 230 defect
- F4166Error codefault cradle system in programme
- F4167Error codefault net interruption
- F4168Error codeFAULT CHIP CARD SLT