- HVAC8BF3F5Error codeSU1 | EOnRoofUnitCompressor2 | LowPressureDisturbance
- HVAC8BF4F4Error codeSU2 | EOnRoofUnitCompressor2 | HighPressureDisturbance
- HVAC8BF4F5Error codeSU2 | EOnRoofUnitCompressor2 | LowPressureDisturbance
- HVAC8BF5F4Error codeSU3 | EOnRoofUnitCompressor2 | HighPressureDisturbance
- HVAC8BF5F5Error codeSU3 | EOnRoofUnitCompressor2 | LowPressureDisturbance
- HVAC8BF6F4Error codeSU4 | EOnRoofUnitCompressor2 | HighPressureDisturbance
- HVAC8BF6F5Error codeSU4 | EOnRoofUnitCompressor2 | LowPressureDisturbance
- HVAC8BF7F4Error codeSU5 | EOnRoofUnitCompressor2 | HighPressureDisturbance
- HVAC8BF7F5Error codeSU5 | EOnRoofUnitCompressor2 | LowPressureDisturbance
- HVAC8BF8F4Error codeSU6 | EOnRoofUnitCompressor2 | HighPressureDisturbance
- HVAC8BF8F5Error codeSU6 | EOnRoofUnitCompressor2 | LowPressureDisturbance
- HVAC8BF9F4Error codeSU7 | EOnRoofUnitCompressor2 | HighPressureDisturbance
- HVAC8BF9F5Error codeSU7 | EOnRoofUnitCompressor2 | LowPressureDisturbance
- HVAC8CF0E3Error codeElemanı 'CU X1/31 | water valve frontbox heating | Short to VBAT'
- HVAC8CF0E4Error codeElemanı 'CU X1/31 | water valve frontbox heating | Short to GND'
- HVAC8CF2F4Error codeSU0 | EOnRoofUnitCompressor3 | HighPressureDisturbance
- HVAC8CF2F5Error codeSU0 | EOnRoofUnitCompressor3 | LowPressureDisturbance
- HVAC8CF3F4Error codeSU1 | EOnRoofUnitCompressor3 | HighPressureDisturbance
- HVAC8CF3F5Error codeSU1 | EOnRoofUnitCompressor3 | LowPressureDisturbance
- HVAC8CF4F4Error codeSU2 | EOnRoofUnitCompressor3 | HighPressureDisturbance
- HVAC8CF4F5Error codeSU2 | EOnRoofUnitCompressor3 | LowPressureDisturbance
- HVAC8CF5F4Error codeSU3 | EOnRoofUnitCompressor3 | HighPressureDisturbance
- HVAC8CF5F5Error codeSU3 | EOnRoofUnitCompressor3 | LowPressureDisturbance
- HVAC8CF6F4Error codeSU4 | EOnRoofUnitCompressor3 | HighPressureDisturbance
- HVAC8CF6F5Error codeSU4 | EOnRoofUnitCompressor3 | LowPressureDisturbance
- HVAC8CF7F4Error codeSU5 | EOnRoofUnitCompressor3 | HighPressureDisturbance
- HVAC8CF7F5Error codeSU5 | EOnRoofUnitCompressor3 | LowPressureDisturbance
- HVAC8CF8F4Error codeSU6 | EOnRoofUnitCompressor3 | HighPressureDisturbance
- HVAC8CF8F5Error codeSU6 | EOnRoofUnitCompressor3 | LowPressureDisturbance
- HVAC8CF9F4Error codeSU7 | EOnRoofUnitCompressor3 | HighPressureDisturbance
- HVAC8CF9F5Error codeSU7 | EOnRoofUnitCompressor3 | LowPressureDisturbance
- HVAC8DF0E3Error codeElemanı 'CU X1/32 | footwell flap | Short to VBAT'
- HVAC8DF0E4Error codeElemanı 'CU X1/32 | footwell flap | Short to GND'
- HVAC8DF2F4Error codeSU0 | EOnRoofUnit1 | CompressorSuctionFault
- HVAC8DF3F4Error codeSU1 | EOnRoofUnit1 | CompressorSuctionFault
- HVAC8DF4F4Error codeSU2 | EOnRoofUnit1 | CompressorSuctionFault
- HVAC8DF5F4Error codeSU3 | EOnRoofUnit1 | CompressorSuctionFault
- HVAC8DF6F4Error codeSU4 | EOnRoofUnit1 | CompressorSuctionFault
- HVAC8DF7F4Error codeSU5 | EOnRoofUnit1 | CompressorSuctionFault
- HVAC8DF8F4Error codeSU6 | EOnRoofUnit1 | CompressorSuctionFault
- HVAC8DF9F4Error codeSU7 | EOnRoofUnit1 | CompressorSuctionFault
- HVAC8EF0E3Error codeElemanı 'CU X1/23 | footwell flap | Short to VBAT'
- HVAC8EF0E4Error codeElemanı 'CU X1/23 | footwell flap | Short to GND'
- HVAC8EF2F4Error codeSU0 | EOnRoofUnit2 | CompressorSuctionFault
- HVAC8EF3F4Error codeSU1 | EOnRoofUnit2 | CompressorSuctionFault
- HVAC8EF4F4Error codeSU2 | EOnRoofUnit2 | CompressorSuctionFault
- HVAC8EF5F4Error codeSU3 | EOnRoofUnit2 | CompressorSuctionFault
- HVAC8EF6F4Error codeSU4 | EOnRoofUnit2 | CompressorSuctionFault
- HVAC8EF7F4Error codeSU5 | EOnRoofUnit2 | CompressorSuctionFault
- HVAC8EF8F4Error codeSU6 | EOnRoofUnit2 | CompressorSuctionFault