Mercedes-Benz All models error codes
Codes
- HVAC52F9E4Error codeElemanında '50Y05: 2/1-Wegeventil Heizung Fahrerarbeitsplatz FAP zusaetzlich' şaseye kısa devre var.
- HVAC53F0F3Error codeElemanı 'CU | CAN - CCVS Pkt Message | Communication Interrupt'
- HVAC53F1F3Error codeCU | SU7 | BlackboxMsg4 (EDB only) | Communication Interrupt
- HVAC53F2E3Error codeElemanı 'SU0 X2/11 | water valve roof heating left | Short to VBAT'
- HVAC53F2E4Error codeElemanı 'SU0 X2/11 | water valve roof heating left | Short to GND'
- HVAC53F3E3Error codeElemanı 'SU1 X2/11 | air flap TopAir roof unit rear right | Short to VBAT'
- HVAC53F3E4Error codeElemanı 'SU1 X2/11 | air flap TopAir roof unit rear right | Short to GND'
- HVAC53F4E3Error codeElemanı 'SU2 X2/11 | water valve roof heating summe r/l | Short to VBAT'
- HVAC53F4E4Error codeElemanı 'SU2 X2/11 | water valve roof heating summe r/l | Short to GND'
- HVAC53F5E3Error codeSubstation3 | Halfbridge X2/11 | Short to Ubatt
- HVAC53F5E4Error codeSubstation3 | Halfbridge X2/11 | Short to ground
- HVAC53F6E3Error codeSubstation4 | Halfbridge X2/11 | Short to Ubatt
- HVAC53F6E4Error codeSubstation4 | Halfbridge X2/11 | Short to ground
- HVAC53F7E3Error codeElemanında '54Y09: Wasserventil HT Heisswasserkreislauf' artı kutba kısa devre var.
- HVAC53F7E4Error codeElemanında '54Y09: Wasserventil HT Heisswasserkreislauf' şaseye kısa devre var.
- HVAC53F8E3Error codeSubstation6 | Halfbridge X2/11 | Short to Ubatt
- HVAC53F8E4Error codeSubstation6 | Halfbridge X2/11 | Short to ground
- HVAC53F9E3Error codeElemanında '50Y05: 2/1-Wegeventil Heizung Fahrerarbeitsplatz FAP zusaetzlich' artı kutba kısa devre var.
- HVAC53F9E4Error codeElemanında '50Y05: 2/1-Wegeventil Heizung Fahrerarbeitsplatz FAP zusaetzlich' şaseye kısa devre var.
- HVAC54F0F3Error codeElemanı 'CU | CAN - CurrLang Pkt Message | Communication Interrupt'
- HVAC54F1F3Error codeAraç içi-CAN iletişiminde fonksiyon arızası var.
- HVAC54F2E3Error codeElemanı 'Substation0 | Halfbridge X2/1 | Short to Ubatt'
- HVAC54F2E4Error codeElemanı 'Substation0 | Halfbridge X2/1 | Short to ground'
- HVAC54F3E3Error codeElemanı 'SU1 X2/1 | air flap TopAir roof unit rear left | Short to VBAT'
- HVAC54F3E4Error codeElemanı 'SU1 X2/1 | air flap TopAir roof unit rear left | Short to GND'
- HVAC54F4E3Error codeElemanı 'SU2 X2/1 | water valve roof cooling summe r/l | Short to VBAT'
- HVAC54F4E4Error codeElemanı 'SU2 X2/1 | water valve roof cooling summe r/l | Short to GND'
- HVAC54F5E3Error codeSubstation3 | Halfbridge X2/1 | Short to Ubatt
- HVAC54F5E4Error codeSubstation3 | Halfbridge X2/1 | Short to ground
- HVAC54F6E3Error codeSubstation4 | Halfbridge X2/1 | Short to Ubatt
- HVAC54F6E4Error codeSubstation4 | Halfbridge X2/1 | Short to ground
- HVAC54F7E3Error codeSubstation5 | Halfbridge X2/1 | Short to Ubatt
- HVAC54F7E4Error codeSubstation5 | Halfbridge X2/1 | Short to ground
- HVAC54F8E3Error codeSubstation6 | Halfbridge X2/1 | Short to Ubatt
- HVAC54F8E4Error codeSubstation6 | Halfbridge X2/1 | Short to ground
- HVAC54F9E3Error codeElemanında '50Y04: 3/2-Wegeventil Heizung Fahrerarbeitsplatz FAP zusaetzlich' artı kutba kısa devre var.
- HVAC54F9E4Error codeElemanında '50Y04: 3/2-Wegeventil Heizung Fahrerarbeitsplatz FAP zusaetzlich' artı kutba kısa devre var.
- HVAC55F0F3Error codeElemanı 'CU | CAN - ET1 Pkt Message | Communication Interrupt'
- HVAC55F1F3Error codeAraç içi-CAN iletişiminde fonksiyon arızası var.
- HVAC55F2E3Error codeElemanı 'SU0 X2/2 | air flap roof unit left | Short to VBAT'
- HVAC55F2E4Error codeElemanı 'SU0 X2/2 | air flap roof unit left | Short to VBAT'
- HVAC55F3E3Error codeElemanı 'SU1 X2/2 | air flap TopAir roof unit rear left | Short to VBAT'
- HVAC55F3E4Error codeElemanı 'SU1 X2/2 | air flap TopAir roof unit rear left | Short to GND'
- HVAC55F4E3Error codeElemanı 'SU2 X2/2 | water valve roof cooling summe r/l | Short to VBAT'
- HVAC55F4E4Error codeElemanı 'SU2 X2/2 | water valve roof cooling summe r/l | Short to GND'
- HVAC55F5E3Error codeSubstation3 | Halfbridge X2/2 | Short to Ubatt
- HVAC55F5E4Error codeSubstation3 | Halfbridge X2/2 | Short to ground
- HVAC55F6E3Error codeSubstation4 | Halfbridge X2/2 | Short to Ubatt
- HVAC55F6E4Error codeSubstation4 | Halfbridge X2/2 | Short to ground
- HVAC55F7E3Error codeSubstation5 | Halfbridge X2/2 | Short to Ubatt