Codes
- HVAC501BF0F3Error code51A17: Steuergerät Unterstation 7 HVAC alt istasyonu parametrelemesi başarısız oldu.
- HVAC501BF0F4Error codeElemanı 'SUx | unused - compressor 2 | high pressure disturbance'
- HVAC501BF0F5Error codeElemanı 'SUx | unused - compressor 2 | low pressure disturbance'
- HVAC501BF0FFError codeElemanı 'CU X3/12,21,30 | highside 6,7,8 - wakeup for substations | Half bridge IC Power Supply Failure'
- HVAC501BF1E2Error codeYolcu çalışma alanının taban bölgesinde ısıtma gücü çok düşük.
- HVAC501BF1E3Error codeElemanında 'SU0 X1/16 solo bus | SU1 X1/16 articulated bus | high pressure sensor cooling fluid - front section (on-roof-unit only) | Short to VBAT' artı kutba kısa devre var.
- HVAC501BF1E4Error codeElemanında 'SU0 X1/16 solo bus | SU1 X1/16 articulated bus | high pressure sensor cooling fluid - front section (on-roof-unit only) | Short to GND' şaseye kısa devre var.
- HVAC501BF1ECError code'Elektrikli soğutma kompresörü' yapı parçasında hatası
- HVAC501BF1F3Error codeCU | CAN - unused - MUX3_B43 - WarmWtrFuelCell_Rq Message | Communication Interrupt
- HVAC501BF2E2Error codeElemanı 'SU0 | EEPROM Checksum Error | ConfigParam'
- HVAC501BF2E3Error codeElemanında 'SU0 X2/6 | hard-wired additional heater on/off | Short to VBAT' artı kutba kısa devre var.
- HVAC501BF2E4Error codeElemanı 'SU0 X2/6 | hard-wired additional heater on/off | Short to GND'
- HVAC501BF2E5Error codeSU0 X1/27 | discharge temperature sensor rear section or solo (on roof unit only) | Open Circuit
- HVAC501BF2E7Error codeElemanı 'SU0 X2/1,2,6 | air flap roof unit left and not used highside 5 (optional) | half bridge IC temperature PreWarning'
- HVAC501BF2E8Error code'SU0 X1/24' yapı elemanı PWM sinyali uymuyor.
- HVAC501BF2EEError codeElemanı 'SU0 | air humidity and dewpoint sensor | Electric Error'
- HVAC501BF2F3Error codeElemanı 'SU0 X2/7,16 | Internal CAN | Bus Off Error'
- HVAC501BF2F4Error codeSU0 | unused - heatpump loop1 | collective disturbance
- HVAC501BF2F5Error codeSU0 | Heat pump compressor 1 | low pressure disturbance
- HVAC501BF2FFError codeElemanı 'SU0 X2/1,2,6 | air flap roof unit left and not used highside 5 (optional) | half bridge IC Power Supply Failure'
- HVAC501BF3E2Error codeElemanı 'SU1 | EEPROM Checksum Error | ConfigParameter'
- HVAC501BF3E3Error codeElemanı 'SU1 X2/2 | air flap TopAir roof unit rear left | Short to VBAT'
- HVAC501BF3E4Error codeElemanı 'SU1 X2/2 | air flap TopAir roof unit rear left | Short to GND'
- HVAC501BF3E5Error codeElemanı 'SU1 X1/18 | prerun heat exchanger cold water - front section (51B35) | Open Circuit'
- HVAC501BF3E7Error codeElemanı 'SU1 X2/1,2,6 | air flap TopAir roof unit rear left or unused highside 5 | Half bridge IC temperature PreWarning'
- HVAC501BF3E8Error codeElemanı 'SU1 X1/33 | diagnostic PWM ventilator - room temperature sensor roof rear | Duty Cycle Out of Valid range'
- HVAC501BF3EEError codeElemanı 'SU1 | Watchdog | Reset'
- HVAC501BF3F3Error codeElemanı 'SU1 X2/7,16 | Internal CAN | Bus Off Error'
- HVAC501BF3F4Error codeSU1 | unused - heatpump loop1 | collective disturbance
- HVAC501BF3F5Error codeSU1 | Heat pump compressor 1 | low pressure disturbance
- HVAC501BF3FFError codeElemanı 'SU1 X2/1,2,6 | air flap TopAir roof unit rear left and unused highside 5 | Half bridge IC Power Supply Failure'
- HVAC501BF4E2Error codeElemanı 'SU2 | EEPROM Checksum Error | ConfigParam'
- HVAC501BF4E3Error codeElemanında 'SU2 X2/1 | water valve roof cooling summe r/l | Short to VBAT' artı kutba kısa devre var.
- HVAC501BF4E4Error codeElemanında 'SU2 X2/1 | water valve roof cooling summe r/l | Short to GND' şaseye kısa devre var.
- HVAC501BF4E5Error codeElemanı 'SU2 X1/18 | diagnostic condenser blowers | Open Circuit'
- HVAC501BF4E7Error codeElemanı 'SU2 X2/1,2,6 | water valve | Half bridge IC temperature PreWarning'
- HVAC501BF4E8Error codeSubstation2 | PWM Input X1/33 | Frequency Out of Valid range
- HVAC501BF4EEError codeElemanı 'SU2 | Watchdog | Reset'
- HVAC501BF4F3Error codeElemanı 'SU2 X2/7,16 | Internal CAN | Bus Off Error'
- HVAC501BF4F4Error codeSU2 | unused - heatpump loop1 | collective disturbance
- HVAC501BF4F5Error codeSU2 | Heat pump compressor 1 | low pressure disturbance
- HVAC501BF4FFError codeElemanı 'SU2 X2/1,2,6 | water valve | Half bridge IC Power Supply Failure'
- HVAC501BF5E2Error codeElemanı 'Substation3 | EEPROM Parameters Download Failed'
- HVAC501BF5E3Error codeHVAC-alt istasyonunda 3 (soket X1, Pin 4) artıya doğru kısa devre var.
- HVAC501BF5E4Error codeYapı elemanı '51A08: Steuergerät Unterstation 3', düşük gerilim algıladı.
- HVAC501BF5E5Error codeHVAC-alt istasyonunda 3 (soket X1, Pin 4) kopukluk var.
- HVAC501BF5E7Error codeSU3 | unused - Servo Motor X1/22,31 or Servo Motor X1/32,23 | Halfbridge IC temperature PreWarning
- HVAC501BF5E8Error codeSubstation3 | PWM Input X1/33 | Frequency Out of Valid range
- HVAC501BF5EEError codeSubstation3 | Watchdog | Reset
- HVAC501BF5F3Error codeSubstation3 | EEPROM parameter configuration error