Mercedes-Benz All models error codes
Codes
- HVAC2DF3E4Error codeElemanı 'SU1 X1/18 | prerun heat exchanger cold water - front section (51B35) | Short to GND'
- HVAC2DF3E5Error codeElemanı 'SU1 X1/18 | prerun heat exchanger cold water - front section (51B35) | Open Circuit'
- HVAC2DF4E3Error codeElemanı 'SU2 X1/18 | diagnostic condenser blowers | Short to VBAT'
- HVAC2DF4E4Error codeElemanı 'SU2 X1/18 | diagnostic condenser blowers | Short to GND'
- HVAC2DF4E5Error codeElemanı 'SU2 X1/18 | diagnostic condenser blowers | Open Circuit'
- HVAC2DF5E3Error codeSubstation3 | Temperature Sensor X1/18 | Short to Ubatt
- HVAC2DF5E4Error codeSubstation3 | Temperature Sensor X1/18 | Short to ground
- HVAC2DF5E5Error codeSubstation3 | Temperature Sensor X1/18 | Open Circuit
- HVAC2DF6E3Error codeSubstation4 | Temperature Sensor X1/18 | Short to Ubatt
- HVAC2DF6E4Error codeSubstation4 | Temperature Sensor X1/18 | Short to ground
- HVAC2DF6E5Error codeSubstation4 | Temperature Sensor X1/18 | Open Circuit
- HVAC2DF7E3Error codeSubstation5 | Temperature Sensor X1/18 | Short to Ubatt
- HVAC2DF7E4Error codeSubstation5 | Temperature Sensor X1/18 | Short to ground
- HVAC2DF7E5Error codeSubstation5 | Temperature Sensor X1/18 | Open Circuit
- HVAC2DF8E3Error codeSubstation6 | Temperature Sensor X1/18 | Short to Ubatt
- HVAC2DF8E4Error codeSubstation6 | Temperature Sensor X1/18 | Short to ground
- HVAC2DF8E5Error codeSubstation6 | Temperature Sensor X1/18 | Open Circuit
- HVAC2DF9E3Error codeElemanında 'Wärmepumpe vorn, deicing switch' artı kutba kısa devre var.
- HVAC2DF9E4Error codeElemanında 'Wärmepumpe vorn, deicing switch' şaseye kısa devre var.
- HVAC2DF9E5Error codeElemanında 'Wärmepumpe vorn, deicing switch' kopukluk var.
- HVAC2EF0E4Error codeElemanı 'CU X1/10,19,28 | frontbox blower and blower floor heater front | VDD - Undervoltage for PWM module'
- HVAC2EF1E2Error codeYolcu çalışma alanının tavan bölgesinde ısıtma gücü çok düşük.
- HVAC2EF2E3Error codeElemanı 'SU0 X2/22 | ECU Supply | Over Voltage'
- HVAC2EF2E4Error codeElemanı 'SU0 X2/22 | ECU Supply | Under Voltage'
- HVAC2EF3E3Error codeElemanı 'SU1 X2/22 | ECU Supply | Over Voltage'
- HVAC2EF3E4Error codeElemanı 'SU1 X2/22 | ECU Supply | Under Voltage'
- HVAC2EF4E3Error codeElemanı 'SU2 X2/22 | ECU Supply | Over Voltage'
- HVAC2EF4E4Error codeElemanı 'SU2 X2/22 | ECU Supply | Under Voltage'
- HVAC2EF5E3Error codeSubstation3 | ECU Supply X2/22 | Over Voltage
- HVAC2EF5E4Error codeYapı elemanı '51A08: Steuergerät Unterstation 3', düşük gerilim algıladı.
- HVAC2EF6E3Error codeSubstation4 | ECU Supply X2/22 | Over Voltage
- HVAC2EF6E4Error codeSubstation4 | ECU Supply X2/22 | Under Voltage
- HVAC2EF7E3Error codeSubstation5 | ECU Supply X2/22 | Over Voltage
- HVAC2EF7E4Error codeYapı elemanı '51A10: Steuergerät Unterstation 5', düşük gerilim algıladı.
- HVAC2EF8E3Error codeSubstation6 | ECU Supply X2/22 | Over Voltage
- HVAC2EF8E4Error codeSubstation6 | ECU Supply X2/22 | Under Voltage
- HVAC2EF9E3Error code'51A17: Steuergerät Unterstation 7' yapı elemanında aşırı gerilim
- HVAC2EF9E4Error codeYapı parçasındaki '51A17: Steuergerät Unterstation 7' düşük gerilim
- HVAC2FF0E4Error codeElemanı 'CU X1/10,19,28 | frontbox blower and blower floor heater front | VREG - Undervoltage for PWM module'
- HVAC2FF1E2Error codeYolcu çalışma alanının taban bölgesinde ısıtma gücü çok düşük.
- HVAC2FF2E3Error code'51B13 (Hava nemi/erime noktası sensörü)' yapı elemanında aşırı gerilim
- HVAC2FF2E4Error codeElemanı 'SU0 X2/18 | air humidity and dewpoint sensor | Under Voltage'
- HVAC2FF3E3Error codeSubstation1 | LIN Supply X2/18 | Over Voltage
- HVAC2FF3E4Error codeSubstation1 | LIN Supply X2/18 | Under Voltage
- HVAC2FF4E3Error code'51A07 (Alt istasyon 2 kumanda kutusu)' kumanda cihazındaki 'LIN-Bus gerilim beslemesi' yapı parçasında aşırı gerilim var.
- HVAC2FF4E4Error code'51A07 (Alt istasyon 2 kumanda kutusu)' kumanda cihazındaki 'LIN-Bus gerilim beslemesi' yapı parçasında düşük gerilim var.
- HVAC2FF5E3Error codeSubstation3 | LIN Supply X2/18 | Over Voltage
- HVAC2FF5E4Error codeSubstation3 | LIN Supply X2/18 | Under Voltage
- HVAC2FF6E3Error codeSubstation4 | LIN Supply X2/18 | Over Voltage
- HVAC2FF6E4Error codeSubstation4 | LIN Supply X2/18 | Under Voltage