- HVAC04F2E3Error codeElemanı 'SU0 X2/20 | compressor clutch | Short to VBAT'
- HVAC04F2E4Error codeElemanı 'SU0 X2/20 | compressor clutch | Short to GND'
- HVAC04F2E5Error codeElemanı 'SU0 X2/20 | compressor clutch | Open Circuit'
- HVAC04F3E3Error codeElemanı 'SU1 X2/20 | HGBP valve front section (on-roof-unit only and articulated bus only) | Short to VBAT '
- HVAC04F3E4Error codeElemanı 'SU1 X2/20 | HGBP valve front section (on-roof-unit only and articulated bus only) | Short to GND '
- HVAC04F3E5Error codeElemanı 'SU1 X2/20 | HGBP valve front section (on-roof-unit only and articulated bus only) | Open Circuit '
- HVAC04F4E3Error codeElemanı 'SU2 X2/20 | compressor clutch | Short to VBAT'
- HVAC04F4E4Error codeElemanı 'SU2 X2/20 | compressor clutch | Short to GND'
- HVAC04F4E5Error codeElemanında 'SU2 X2/20' kopukluk var.
- HVAC04F5E3Error codeSubstation3 | Powerstage X2/20 | Short to Ubatt
- HVAC04F5E4Error codeSubstation3 | Powerstage X2/20 | Short to ground
- HVAC04F5E5Error codeSubstation3 | Powerstage X2/20 | Open Circuit
- HVAC04F6E3Error codeSubstation4 | Powerstage X2/20 | Short to Ubatt
- HVAC04F6E4Error codeSubstation4 | Powerstage X2/20 | Short to ground
- HVAC04F6E5Error codeSubstation4 | Powerstage X2/20 | Open Circuit
- HVAC04F7E3Error codeElemanında 'Kumanda kutusu 'Genleşme valfının ayarlanması'' artı kutba kısa devre var.
- HVAC04F7E4Error codeElemanında 'Kumanda kutusu 'Genleşme valfının ayarlanması'' şaseye kısa devre var.
- HVAC04F7E5Error codeElemanında 'Kumanda kutusu 'Genleşme valfının ayarlanması'' kopukluk var.
- HVAC04F8E3Error codeElemanında 'Kumanda kutusu 'Genleşme valfının ayarlanması' ( Ön araç )' artı kutba kısa devre var.
- HVAC04F8E4Error codeElemanında 'Kumanda kutusu 'Genleşme valfının ayarlanması' ( Ön araç )' şaseye kısa devre var.
- HVAC04F8E5Error codeElemanında 'Kumanda kutusu 'Genleşme valfının ayarlanması' ( Ön araç )' kopukluk var.
- HVAC04F9E3Error codeSubstation7 | Powerstage X2/20 | Short to Ubatt
- HVAC04F9E4Error codeSubstation7 | Powerstage X2/20 | Short to ground
- HVAC04F9E5Error codeSubstation7 | Powerstage X2/20 | Open Circuit
- HVAC05F0E2Error codeKalorifer CAN-Bus' u: 5 Alt istasyonu ile iletişim kesilmiş.
- HVAC05F0E3Error codeControl Unit | Powerstage X3/30 | Short to Ubatt
- HVAC05F0E4Error codeControl Unit | Powerstage X3/30 | Short to ground
- HVAC05F1E2Error code'SU0 X1/16 solo bus | SU1 X1/16 articulated bus | high pressure sensor cooling fluid - front section (on-roof-unit only) | Implausible Error' elemanında fonksiyon arızası var.
- HVAC05F1E3Error codeElemanında 'SU0 X1/16 solo bus | SU1 X1/16 articulated bus | high pressure sensor cooling fluid - front section (on-roof-unit only) | Short to VBAT' artı kutba kısa devre var.
- HVAC05F1E4Error codeElemanında 'SU0 X1/16 solo bus | SU1 X1/16 articulated bus | high pressure sensor cooling fluid - front section (on-roof-unit only) | Short to GND' şaseye kısa devre var.
- HVAC05F1E5Error codeÇıkışta Kopukluk var:Ausgang für Wasserpumpe 'Bodenkreislauf vorn'
- HVAC05F2E3Error codeElemanında 'SU0 X2/6 | hard-wired additional heater on/off | Short to VBAT' artı kutba kısa devre var.
- HVAC05F2E4Error codeElemanı 'SU0 X2/6 | hard-wired additional heater on/off | Short to GND'
- HVAC05F2E5Error codeElemanında '53M11: Motor Mischkreislauf Pumpe Dach' kopukluk var.
- HVAC05F3E3Error codeSubstation 2 | Output X18/4 | Short To UBatt
- HVAC05F3E4Error codeSubstation 2 | Output X18/4 | Short To Ground
- HVAC05F3E5Error codeSubstation 2 | Output X18/4 | Open Circuit
- HVAC05F4E3Error codeElemanında 'SU2 X2/1 | water valve roof cooling summe r/l | Short to VBAT' artı kutba kısa devre var.
- HVAC05F4E4Error codeElemanında 'SU2 X2/1 | water valve roof cooling summe r/l | Short to GND' şaseye kısa devre var.
- HVAC05F4E5Error codeSubstation 3 | Output X18/4 | Open Circuit
- HVAC05F5E3Error codeSU3 | unused - Powerstage X2/6 | Short to VBAT
- HVAC05F5E4Error codeSU3 | unused - Powerstage X2/6 | Short to GND
- HVAC05F5E5Error codeGiriş ve çıkış döşenmemiş.
- HVAC05F6E3Error codeSU4 | unused - Powerstage X2/6 | Short to VBAT
- HVAC05F6E4Error codeSU4 | unused - Powerstage X2/6 | Short to GND
- HVAC05F6E5Error codeGiriş ve çıkış döşenmemiş.
- HVAC05F7E3Error codeElemanında 'Elektrikli genleşme valfi 'Soğutma devreleri için plakalı ısı değiştiricisi'' artı kutba kısa devre var.
- HVAC05F7E4Error codeElemanında 'Elektrikli genleşme valfi 'Soğutma devreleri için plakalı ısı değiştiricisi'' şaseye kısa devre var.
- HVAC05F7E5Error codeGiriş ve çıkış döşenmemiş.
- HVAC05F8E3Error codeElemanında 'Elektrikli genleşme valfi 'Soğutma devreleri için plakalı ısı değiştiricisi' ( Ön araç )' artı kutba kısa devre var.