Mercedes-Benz All models error codes
Codes
- CPC302T4F0E3Error codeAccelerator pedal sensor 1 supply (DO_LP_HS_01) - Short to High
- CPC302T4F0E4Error codeAccelerator pedal sensor 1ground (DO_LP_LS_03) - Short to GND
- CPC302T4F3E2Error codeLIN node STSR: Drivemodeswitch: Error Position implausible
- CPC302T4F3ECError codeLIN node STSR: Drivemodeswitch: HW error potentiometer 1 and 2
- CPC302T4F3EEError codeITPM Error: Vehicle calibration inconsistent
- CPC302T5F0E3Error codeAccelerator pedal sensor 2 supply (DO_LP_HS_02) - Short to High
- CPC302T5F0E4Error codeAccelerator pedal sensor 2 ground (DO_LP_LS_04) - Short to GND
- CPC302T5F3E2Error codeLIN node STSR: Retarderswitchposition: Plausibility error microswitch and hallsensor
- CPC302T5F3E7Error codeLIN node STSR: Retarderswitchposition: HW error microswitch
- CPC302T5F3ECError codeLIN node STSR: Retarderswitchposition: Error hallsensor
- CPC302T5F3EEError codeLIN node STSR: Retarderswitchposition: Error microswitch and hallsensor
- CPC302T5FFEEError codeTest bench active
- CPC302T6F0ECError codePPC data - CAN timeout
- CPC302T6F3EEError codeXSS configuration inconsistent
- CPC302T6F3F3Error codeLIN node STSR: Response Error Current state STSR in LIN component
- CPC302T7F3ECError codeLIN node STSR: General electric failure STSR
- CPC302T8F3EEError codeAG: No gear switchable
- CPC302T8FFE3Error codeCPC internal - no driver shutdown by watchdog
- CPC302T9F3EEError codeAG: Unexpected shift behaviour
- CPC302T50D03Error codeCoolant level sensor (CL_5V/CL_SENS) - Short to High
- CPC302T50D04Error codeCoolant level sensor supply (CL_5V) - Short to Low
- CPC302T60D0EError codeAGND_01 - Short to Low or Open Circuit
- CPC302T60D02Error codeAir filter supply (AF_5V) - Short to High or GND
- CPC302T60D03Error codeAGND_01 - Short to High
- CPC302T60D04Error codeAir filter supply (AF_5V) - Short to GND
- CPC302T70D0EError codeAGND_03 - Short to GND
- CPC302T70D03Error codeAGND_03 - Short to High
- CPC302T90A07Error codeair filter dirty/blocked
- CPC302T4150EError codeChassis-CAN (VCAN/Prop Net #2) - Busoff
- CPC302T6060CError codeVRDU data - CAN timeout
- CPC302T8000EError codeOptimized Idle: charging system or battery failure
- CPC302T60202Error codeCPC internal - EEPROM checksum error in supplier area
- CPC302T70902Error codeRotation speed of the generator (T_ALT_W) Open Circuit or Short to GND or UBATT or v-belt slips
- CPC302T80000Error codeT30, T15 Overvoltage
- CPC302T80001Error codeT30, T15 Undervoltage
- CPC302T80002Error codeTerminal 15 state implausible
- CPC302T80005Error codeT_30 - Open Circuit
- CPC302T80602Error codeTachograph (TO_SP_SENS) frequency fault
- CPC302T80603Error codeTachograph input (TO_SP_SENS) - Short to High or Open Circuit
- CPC302T80604Error codeTachograph input (TO_SP_SENS) - Short to GND
- CPC302TA050CError codeTCM data not plausible
- CPC302TA050EError codeTCM J1939 source address 3 timeout
- CPC302TAF3EEError codePTConf Error: No response from MCM for requests
- CPC302TB000CError codeAccelerator pedal sensor (AP1_PWM, AP2_PWM) drifted out of learned range
- CPC302TB000DError codeAccelerator pedal (AP1_PWM, AP2_PWM) wrong paramezation
- CPC302TB0002Error codeAccelerator pedal (AP1_PWM, AP2_PWM) defective
- CPC302TB0003Error codeAmbient air temperature sensor input (AI_01 or AI_07) - Short to High or Open Circuit
- CPC302TB0004Error codeAmbient air temperature sensor input (AI_01 or AI_07) - Short to Low
- CPC302TB0007Error codeAccelerator pedal (AP1_PWM, AP2_PWM) blocked
- CPC302TB0008Error codeAccelerator pedal sensor input 1 (AP1_PWM) - Open Circuit or Short to High or GND