Gree All models error codes
Codes
- J8Error codeOver-high pressure ratio protection
- L0Error codeHydro box malfunction
- L4Error codePower supply over-current protection
- L7Error codeThe master IDU is powered off. The communication of the master IDU fails. The main board of the master IDU is faulty. No master IDU is set in the system
- LAError codeDış Ünite DC Fan Motoru Arızası
- LEError codeKompresörün Ani Durmalara Karşı Koruması
- n6Error codeOperation method: In "n6" status, press "MODE" button to enter the query of outdoor unit error code (If the wired controller controls multiple indoor units, only the errors memorized by the indoor unit that has the smallest project number can be queried). Press " " or " " button to switch the error number. Press -SWING/ENTER‖ button to return to the upper-level menu. Display mode: Temperature zone displays the error number and error code from left to right (1~5, errors are arranged from the earliest to the latest). Timer zone displays the project code of outdoor unit
- of1Error codeAmbient temperature
- of2Error codeAmbient temperature
- P1Error codeSuction pressure
- P3Error codeCompressor drive module reset protection
- P22Error codeCorrected value of ambient temperature sensor of indoor unit (for heating, fast heating and warming mode)
- P37Error codeCooling temperature setting for auto mode
- P38Error codeHeating temperature setting for auto mode
- P48Error codeMinimum opening degree setting for heating breakdown of indoor unit expansion valves
- P49Error codeHighest hot water temperature setting of water tank
- P50Error codeSetting of cooling air discharge temperature for fresh air indoor unit
- P51Error codeSetting of heating air discharge temperature for fresh air indoor
- P52Error codeSetting of indoor fan speed in AHRI energy efficiency test mode
- P53Error codeSetting of water pump status in special
- P54Error codeCycling days of high-temperature sterilizing
- P55Error codeSetting of static pressure for DC fresh air unit
- P59Error codeWater temperature setting of auto heat recovery
- P65Error codeOperating time of water returning pump
- P74Error codeHighest water outlet temperature automatically set by floor heating
- P75Error codeLowest water outlet temperature automatically set by floor heating
- P76Error codeAutomatically setting revision value of floor heating water temperature
- P77Error codeHighest notch B of water pump of hydro box
- P79Error codeSetting of corresponding engineering number of indoor unit for shunt valve
- P81Error codeMaximum setting value of floor heating water yielding temperature
- PAError codeAC Akım Koruması
- PEError codeSıcaklık Değişimlerinden Koruma
- PFError codeDış Ünite Güç Modül Kartı Sensör Hatası
- PJError codeInverter compressor startup failure
- PUError codeKapasitör Şarj Hatası
- s0Error codepeed Pressure protection switch for fan speed adjustment
- s1Error codeystem Interface of high pressure protection
- s2Error codeystem Interface of low pressure protection
- SA6Error codeStatic pressure(Pa)
- T1Error codeTemperature Air- inlet
- T2Error codeTemperature Air- outlet
- T3Error codeTemperature Air- inlet
- T4Error codeTemperature Air- outlet
- tE1Error codetE / tE1 / EC
- U5Error codeAC akım algılama devresi arızası
- U6Error codeWarning against valve error