CNC All models error codes
Codes
- 1Error codeDisconnection
- 02Error codeControl Voltage Low
- 2Error codeDischarge Alarm
- 3Error codeOvervoltage
- 4Error codeAbnormal Current
- 5Error codeOvercurrent
- 6Error codeLow Voltage
- 7Error codeOverload
- 40-49Error codeExcessive following error on axis 0 to 9
- 50-59Error codeExcessive following error on axis 10 to 19
- 60-69Error codeExcessive following error on axis 20 to 29
- 70-71Error codeExcessive following error on axis 30 and 31
- 114Error code
- A6Error codeFan stop warning
- AL-02Error codeGenellikle yükte iken devir kaybı olduğunu gösterir. Kayışların gevşekliğini veya spindle motorunun manyetik sensörünün kirlendiğini/kaydığını kontrol edin
- AL-24Error codeSerial Link Error
- AT343Error codeMitsutoyo
- DS0001Error codeIn feed axis control , the difference in the amount of positional deviation between the master and slave axes exceeded the parameter (No. 8323) setting value. This alarm occurs only for the slave axis
- DS0004Error codeThe malfunction prevention function detected the command in which a value exceeding the maximum speed was specified
- DS0005Error codeThe malfunction prevention function detected the command in which a value exceeding the maximum acceleration was specified
- DS0006Error codeThe malfunction prevention function detected an illegal execution sequence
- DS0007Error codeThe malfunction prevention function detected an illegal execution sequence
- DS0008Error codeThe malfunction prevention function detected an illegal execution sequence
- DS0009Error codeThe malfunction prevention function detected an illegal execution sequence
- DS0010Error codeThe malfunction prevention function detected an invalid reference area
- DS0011Error codeThe malfunction prevention function detected an invalid reference area
- DS0012Error codeThe malfunction prevention function detected an invalid reference area
- DS0013Error codeThe malfunction prevention function detected an invalid reference area
- DS0016Error code1) The settings of parameters No.1883 and No.1884 fall outside the range. 2) The current position at establishment of the reference position subtracted by the distance between the reference positions (detection unit) exceeded ±2147483647. Change the current position or reference position to prevent this situation
- DS0021Error codeA macro program start operation cannot be accepted. 1) The feed hold signal *SP is 0. 2) An alarm is generated. 3) The SRN signal is 1
- DS0131Error codeAn attempt was made to display an external operator message or external alarm message, but five or more displays were required simultaneously
- DS0132Error codeAn attempt to cancel an external operator message or external alarm message failed because the specified message number was not found
- DS0133Error codeA value other than 0 to 4095 was specified as the external operator message or the external alarm message number
- DS0300Error codeA setting to zero position for the absolute position detector (association with reference position and the counter value of the absolute position detector) is required. Perform the return to the reference position. This alarm may occur with other alarms simultaneously. In this case, other alarms must be handled first
- DS0306Error codeThe battery voltage of the absolute position detector has dropped to a level at which data can no longer be held. Or, the power was supplied to the Pulsecoder for the first time. If this problem recurs after the power is turned off and then back on, the battery or cable may be defective.
- DS0307Error codeThe battery voltage of the absolute position detector has dropped to a level at which a replacement is required.
- DS0308Error codeThe battery voltage of the absolute position detector dropped to a level at which a replacement was required in the past.
- DS0405Error codeThe axis specified in automatic zero return was not at the correct zero point when positioning was completed. Perform zero return from a point whose distance from the zero return start position to the zero point is 2 or more revolutions of the motor. Other probable causes are: - The positional deviation after triggering the deceleration dog is less than 128. - Insufficient voltage or malfunctioning Pulsecoder
- DS1124Error codeOUTPUT REQUEST ERROR An output request was issued during external data output, or an output request was issued for an address that has no output data
- DS1150Error codeA/D converter malfunction
- DS2003Error codeThe spindle controlled with the servo motor is set as a PMC-controlled axis
- E1Error codeOverload warning
- E8Error codePower supply warning
- ER01Error code
- ER17Error code
- ER33Error code
- ER43Error code
- ER97Error code
- IE0001Error codeThe malfunction prevention function detected that stored stroke check 1 on the positive side was exceeded
- IE0002Error codeThe malfunction prevention function detected that stored stroke check 1 on the negative side was exceeded