Carrier Aquasnap All models error codes
Codes
- T5Error codeAllows to read and reset the alarms
- T8Error codeSpace Temperature Thermistor
- T112Error codeCircuit A High Saturated Suction Temperature
- T113Error codeCircuit B High Saturated Suction Temperature
- T114Error codeCircuit A Low Suction Superheat
- T115Error codeCircuit B Low Suction Superheat
- T116Error codeCircuit A Low Cooler Suction Temperature
- T117Error codeCircuit B Low Cooler Suction Temperature
- T118Error codeHigh Discharge Gas Temperature Alert
- T126Error codeCircuit A High Discharge Pressure
- T127Error codeCircuit B High Discharge Pressure
- T133Error codeCircuit A Low Suction Pressure
- T134Error codeCircuit B Low Suction Pressure
- T153Error codeReal Time Clock Hardware Failure
- T155Error codeSerial EEPROM Storage Failure
- T170Error codeLoss of communication with the Compressor Expansion Module
- T173Error codeLoss of Communication with EMM
- T174Error code4 to 20 mA Cooling Set Point Input Failure
- T175Error codeLoss of Communication with the AUX Board
- T176Error code4 to 20 mA Temperature Reset Input Failure
- T177Error code4 to 20 mA Demand Limit Input Failure
- T190Error codeCooler Pump 1 Aux Contacts Failed to Close at Start-Up
- T191Error codeCooler Pump 2 Aux Contacts Failed to Close at Start-Up
- T192Error codeCooler Pump 1 Failed to Provide Flow at Start-Up
- T193Error codeCooler Pump 2 Failed to Provide Flow at Start-Up
- T194Error codeCooler Pump 1 Aux Contacts Opened During Normal Operation
- T195Error codeCooler Pump 2 Aux Contacts Opened During Normal Operation
- T196Error codeFlow Lost While Pump 1 Running
- T197Error codeFlow Lost While Pump 2 Running
- T198Error codeCooler Pump 1 Aux Contacts Closed While Pump Off
- T199Error codeCooler Pump 2 Aux Contacts Closed While Pump Off
- T200Error codeCooler Flow/Interlock Contacts failed to Close at start-up
- T203Error codeLoss of Communication with slave chiller
- T204Error codeLoss of Communication with master chiller
- T206Error codeHigh Leaving Chilled Water Temperature
- T300Error codeCooler Pump 1 Scheduled Maintenance Due
- T301Error codeCooler Pump 2 Scheduled Maintenance Due
- T500Error codeCurrent Sensor Board A1 Failure
- T501Error codeCurrent Sensor Board A2 Failure
- T502Error codeCurrent Sensor Board A3 Failure
- T503Error codeCurrent Sensor Board B1 Failure
- T504Error codeCurrent Sensor Board B2 Failure
- T505Error codeCurrent Sensor Board B3 Failure
- T950Error codeLoss of Communication with Water System Manager
- T951Error codeLoss of Communication with Chillervisor System Manager
- T952Error codeLoss of Communication with Hydronic System Manager
- th-21Error codeSpace Temperature Thermistor
- tor10Error codeOutdoor Fan Motor 10 OF
- tor11Error codeOutdoor Fan Motor 11 OF
- tor12Error codeOutdoor Fan Motor 12 OF