Carrier Aquasnap All models error codes
Codes
- A1NError codeThe hydraulic cooling circuit includes a single low-pressure centrifugal pump. The circuit also contains the safety valve and the manual shut-off valves
- A1PError codeThe hydraulic cooling circuit includes a storage tank and single variable speed low-pressure centrifugal pump, equipped with Low noise motor (4 poles), Also provided in the hydraulic circuit are an expansion vessel, pressure relief valve and system isolating valves with fittings
- A1VError codeThe hydraulic heating circuit includes a single variable speed, low-pressure centrifugal pump. The circuit also contains the safety valve and the manual shut-off valves."
- A1ZError codeThe hydraulic cooling circuit includes a storage tank and single low-pressure centrifugal pump. Also provided in the hydraulic circuit are an expansion vessel, pressure relief valve and system isolating valves with fittings
- A2Error codeTahliye basıncı güvenliği
- A2-01Error codeCompressor A2 Motor Temperature Too High
- A2-02Error codeCompressor A2 Crankcase Heater Failure
- A2-03Error codeCompressor A2 High Pressure Switch
- A2-04Error codeCompressor A2 Motor Temperature Sensor PTC Out Of Range
- A2-06Error codeCompressor A2 Low Control Voltage Alert
- A2NError codeThe hydraulic heating circuit includes 2 pumps (running+stand-b) low-pressure centrifugal pump. The circuit also contains the safety valve and the manual shut-off valves
- A2ZError codeThe hydraulic cooling circuit includes a storage tank and 2 pumps (running+stand- by) low-pressure centrifugal pump. Also provided in the hydraulic circuit are an expansion vessel, pressure relief valve and system isolating valves with fittings
- A3Error codeÇıkış suyu sıcaklığı sınırın altında
- A3-01Error codeCompressor A3 Motor Temperature Too High
- A3-02Error codeCompressor A3 Crankcase Heater Failure
- A3-03Error codeCompressor A3 High Pressure Switch
- A3-04Error codeCompressor A3 Motor Temperature Sensor PTC Out Of Range
- A3-06Error codeCompressor A3 Low Control Voltage Alert
- A4Error codeCompressor motor tripped
- A4-01Error codeCompressor A4 Motor Temperature Too High
- A4-02Error codeCompressor A4 Crankcase Heater Failure
- A4-03Error codeCompressor A4 High Pressure Switch
- A4-04Error codeCompressor A4 Motor Temperature Sensor PTC Out Of Range
- A4-06Error codeCompressor A4 Low Control Voltage Alert
- A5Error codeKompresör tahliyesi çok sıcak
- A6Error codeSoğutulmuş su akışı kayboldu
- A8Error codeKompresör termal koruması
- A156Error codeCritical Serial EEPROM Storage Failure
- A157Error codeA/D Hardware Failure
- A172Error codeLoss of Communication with EXV Board
- A189Error codeCooler Pump Auxiliary Contact Inputs Miswired
- A198Error codeCooler Pump 1 Aux Contacts Closed While Pump Off
- A199Error codeCooler Pump 2 Aux Contacts Closed While Pump Off
- A207Error codeCooler Freeze Protection
- A208Error codeEWT or LWT Thermistor failure
- A220Error codeCondenser Pump Interlock Failure to Close at Start-Up
- A221Error codeCondenser Pump Interlock Opened During Normal Operation
- A222Error codeCondenser Pump Interlock Closed When Pump is Off
- ACF19Error codeUser water flow switch alarm
- AP1Error codeAlarm user inlet water temperature sensor
- AP11Error codeAlarm expansion probe 1 (if used)
- AP21Error codeAlarm expansion probe 2 (if used)
- B1Error codeCompressor B1 Failure
- B1-01Error codeCompressor B1 Motor Temperature Too High
- B1-02Error codeCompressor B1 Crankcase Heater Failure
- B1-03Error codeCompressor B1 High Pressure Switch
- B1-04Error codeCompressor B1 Motor Temperature Sensor PTC Out Of Range
- B1-06Error codeCompressor B1 Low Control Voltage Alert
- B2Error codeCompressor B2 Failure
- B060Error codeFan Panosu/Kanalı