Alarko All models error codes
Codes
- E96Error codeŞebeke voltajı düşük/yüksek
- E98Error codeGenel iç iletişim veya yazılım koruma kodu; teknik müdahale gerekir
- E99Error codeServis modu / fabrika test kodu veya ciddi iç hata göstergesi
- EEError codeTuş Kilidi (Normal)
- F0Error codeSensör Arızaları
- F1Error codeOda Sensörü (Split)
- F1xError codeDonma koruma, pompa sıkışma önleme
- F2Error codeİç Batarya Sensörü
- F4Error codeSahte alev - gaz vanası kapalıyken brülörde alev algılanıyor
- F05Error codeFan veya hava akış hatası
- F5Error codeFark basınç anahtarı problemi (hava akışı arızası)
- FFError codeBağlantı
- H2OError codeSu basıncı düşük (Seradens SRD ailesi) - rakam yerine H2O yazısı yanar
- H20Error codeSİSTEMDE SU YETERSİZ
- HSError codeDefrost (Normal)
- m3Error codePompa tipine göre, bkz.Ekler
- P02Error codeGaz tipini seçme
- P03Error codeWorking temperature range on heating (CH) cycle
- P04Error codeFan speed at start-up (during ignition) (rpm equivalent of this fan speed is calculated by multiplying entered value by 40)
- P05Error codeFan speed at minimum capacity for DHW cycle (rpm equivalent of this fan speed is calculated by multiplying entered value by 40)
- P06Error codeFan speed at maximum capacity for DHW cycle (rpm equivalent of this fan speed is calculated by multiplying entered value by 40 and adding 2500)
- P07Error codeFan speed at minimum capacity for CH cycle (rpm equivalent of this fan speed is calculated by multiplying entered value by 40)
- P16Error codeIt is used for commissioning modulating pump if it is used in the appliance
- P18Error codeModulating pump minimum power (% of pump maximum speed)
- P19Error codeModulating pump maximum power (% of pump maximum speed)
- P20Error codeModulating pump brand/model selection
- P21Error codeOutside temperature compensation coefficient (KD in Figure 3). KD value equals the value of this parameter divided by 10.
- P22Error codeThe type of the flow sensing component used in the appliance. If flow sensor is used, the flame is generated according to the flow rate. If the parameter value is set to 10, then the flame is formed at flow rate of 1 l/min. Likewise, if it is 20, then the flame generation flow rate is 2 l/min
- P23Error codeThe time interval in which fan speed falls from a set value (threshold value) to the minimum fan speed. Fan speed drops suddenly until the threshold value, it decreases in time from this value to the minimum. This property is used to prevent fan speed from falling to “0” suddenly when heating need is instantly over (for example when hot water tap is closed). 200 value of this parameter corresponds to approximately 5 seconds. The service people must not modify this parameter unless there is an emergency condition
- P24Error codeThe threshold value which is the first stop point of suddenly falling fan speed in case the heating need is over (rpm equivalent of this fan speed is calculated by multiplying entered value by 40). The service people must not modify this parameter unless there is an emergency condition
- P26Error codeThe type of the pressure sensing component used in the appliance
- P28Error codeDemo mode enabled/disabled. Demo mode makes it possible to navigate on menu without encountering any error code. It can be used in exhibition halls or showrooms to introduce the appliance to customers only with an electrical connection
- SSP20Error codeItem
- SSP24Error codeItem
- SSP28Error codeItem
- SSP36Error codeItem