ACS Klima fan All models error codes
Codes
- P22Error codeDC BRAKE VOLTAGE 0%
- P25Error codeCurrent limit: (%)
- P26Error codeMotor overload: 100
- P50Error codeFAULT HISTORY - Last 8 faults
- P52Error codeDC BUS VOLTAGE - in percent of nominal. Usual-
- P53Error codeMOTOR VOLTAGE - in percent of rated output
- P54Error codeLOAD - in percent of drives rated output current
- P67Error codeMin alarm
- P68Error codeMax alarm
- P120Error codeCircuit A Low Saturated Suction Temp-Comp A2 Shutdown
- P121Error codeCircuit B Low Saturated Suction Temp-Comp B2 Shutdown
- P126Error codeCircuit A High Head Pressure, Comp Shutdown
- P127Error codeCircuit B High Head Pressure Comp Shutdown
- RMS01Error codeActive Alarm ------------------------ Active Alarm ------------------------ Active Alarm ------------------------ Active Alarm ------------------------
- S1Error codeGENERAL INPUTS Filter Status Input Fan Request From IGC Remote Input State Economizer Control Input Remote Economizer Enable Econo Position Override Supply Fan Status Switch Demand Limit Switch 1 Demand Limit Switch 2 Dehumidify Switch Input
- T24Error codeEconomizer Installed? Return Air Temperature Air Temp Lvg Supply Fan Outside Air Temperature Occupied? Supply Air State Supply Fan VFD Speed Economizer Act. Curr. Pos. Economizer Act. Cmd. Pos OK to Use Economizer? Ok Test Mech. D/C Act. Title 24 Previous SAT Title 24 Econ Samp Pos Title 24 SAT Check Time Elapsed Seconds Title 24 Test Mark RAT-OAT OK for Title 24
- T051Error codeCircuit A, Compressor 1 Failure
- T052Error codeCircuit A, Compressor 2 Failure
- T055Error codeCircuit B, Compressor 1 Failure
- T056Error codeCircuit B, Compressor 2 Failure
- T064Error codeCircuit A Saturated Temperature Transducer Failure
- T065Error codeCircuit B Saturated Temperature Transducer Failure
- T072Error codeEvaporator Discharge Reset Sensor Failure
- T073Error codeOutside Air Temperature Thermistor Failure
- T074Error codeSpace Temperature Thermistor Failure
- T075Error codeReturn Air Thermistor Failure
- T076Error codeOutside Air Relative Humidity Sensor Failure
- T077Error codeSpace Relative Humidity Sensor Failure
- T078Error codeReturn Air Relative Humidity Sensor Failure
- T082Error codeSpace Temperature Offset Sensor Failure
- T090Error codeCircuit A Discharge Pressure Transducer Failure
- T091Error codeCircuit B Discharge Pressure Transducer Failure
- T092Error codeCircuit A Suction Pressure Transducer Failure
- T093Error codeCircuit B Suction Pressure Transducer Failure
- T120Error codeCircuit A Low Saturated Suction Temperature Alert
- T121Error codeCircuit B Low Saturated Suction Temperature Alert
- T122Error codeCircuit A High Saturated Suction Temperature (or at Startup)
- T123Error codeCircuit B High Saturated Suction Temperature (or at Startup)
- T126Error codeCircuit A High Head Pressure Alert
- T127Error codeCircuit B High Head Pressure Alert
- T128Error codeDigital Scroll High Discharge Temperature Alert
- T153Error codeReal Time Clock Hardware Failure
- T155Error codeSerial EEPROM Storage Failure Error
- T177Error code4-20 mA Demand Limit Failure
- T178Error code4-20 mA Static Pressure Reset/VFD Fail
- T210Error codeBuilding Pressure Transducer Failure
- T211Error codeStatic Pressure Transducer Failure
- T220Error codeIndoor Air Quality Sensor Failure
- T221Error codeOutdoor Air Quality Sensor Failure
- T229Error codeEconomizer Minimum Position Override Input Failure