Destron mikroçip okuyucu Because printers vary in their capacity error codes
Codes
- E-4Error codeIs the convection fan motor operating when the error code occurs? See “No Convection Motor Operation”. No Yes Is the hall effect sensor (HES) registering a motor speed (Approximately 1500 for high speed and approximately 700 Test HES connection points and for low speed)?* ensure HES wires are installed No Yes on the appropriate terminals of the low voltage relay board. Is there 10 VDC across Confirm 12 VDC to LRB. when the motor is stopped? Yes Replace faulty motor Is there 3-5 VDC across due to failed HES. No the Red-Brown HES wires when the motor is running? Yes If E3 continues to display, contact Alto-Shaam factory Technical Support. *Note: This can be seen in the service remote control. The speeds should closely match
- e02Error codeControl Temperature High
- e03Error codeFan Motor Error
- e04Error codeFan Motor 2 Error
- e11Error codeConvection Temperature High
- e13Error codeBoiler Temperature High
- e15Error codeCondenser Temperature High
- e20Error codeB11 Core Temperature Probe Single Point Fault - HACCP only
- e21Error codeN6 Cavity Probe Fault
- e22Error codeB10 Core Temp Probe Fault
- e23Error codeB4 Boiler Probe Fault
- e24Error codeB5 Bypass Probe Fault
- e25Error codeB3 Condenser Probe Fault
- e26Error codeN8 Boiler Safety Temperature Probe Fault
- e27Error codeBoiler Element Temperature High
- e34Error codeSteam Generator Drain Pump Fault
- e36Error codeSteam Temperature High
- e53Error codeFan Motor High Temperature
- e54Error codeFan Motor 2 High Temperature
- e93Error codeCommunication Error FROM Display Board
- e94Error codeCommunication Error TO Display Board