Delta Ohm anemometre All models error codes
Codes
- aD0Error codea<Measurements><CR><LF> ⋅ ⋅ ⋅ a<Measurements><CR><LF> where: a = address of the instrument (1 character) <Measurements> = sequence of measured values Commands aD1!, aD2!, etc. are sent only if all the expected values are not received with command aD0!. y y y ⇒ Sequence of measurements in the most complete model: <WS><WD><T><RH><AH><DP><P><R><C> with: <WS> = wind speed <WD> = wind direction in degrees <T> = temperature (sensor Pt100) <RH> = relative humidity in %RH <AH> = absolute humidity in g/m3 <DP> = dew point temperature <P> = barometric pressure <R> = solar radiation in W/m2 <C> = compass angle in degrees Notes: The positive values are always preceded by a + sign to identify the beginning of the measurement value. <DP> measurement has the same format as tem- perature. If a quantity measurement is in error condition, all the digits of the sent value will consist in a series of 9. The fields corresponding to quantities not meas- ured by that particular model are always present. A value consisting in a serie
- HD52Error codeMast HD 52.3DP Wind speed, wind direction and solar radiation. HD 52.3DP4 Wind speed, wind direction, solar radiation and barometric pressure
- RU4MError code& n
- RU5MError code& n
- RU5WError code& n