CNC All models error codes
Codes
- SP9141Error codeSerial sensor one-rotation signal undetected
- SR67AError codeMagnescale
- SUError code01 veya AL -24 dışındaki alarm koşulları altında açıldığında
- SV0001Error codeIn feed axis control , the amount of compensation for synchronization exceeded the parameter (No. 8325) setting value. This alarm occurs only for a slave axis
- SV0002Error codeIn feed axis control , the amount of synchronization error exceeded the parameter (No. 8332) setting value. When the synchronization is not completed after power-up, the determination is made by the parameter value (No. 8332) multiplied by the parameter (No. 8330) multiplier. This alarm occurs only for a slave axis only
- SV0003Error codeT Since as axis in synchronization, composite, or superimposed mode caused a servo alarm, the mode could not be continued, If one of the axes in a mode causes a servo alarm, all axes relating to the axis enter the servo-off state. This alarm is generated to enable the cause of the servo-off state to be checked
- SV0005Error codeIn feed axis control , for synchronization, the difference value of the machine coordinate between a master and slave axes exceeded the parameter (No. 8314) setting value. This alarm occurs for a master or slave axis
- SV0007Error codeT When a multiaxis amplifier was used in a 2-path system across paths, a servo alarm occurred on an axis belonging to another path. When a 2-path system and multiple servo axes between paths are controlled by a multiaxis amplifier, if a servo alarm occurs on an axis belonging to another path of the same amplifier, the MCC of the amplifier goes down and SV0401 V-READY OFF occurs on an axis belonging to the local path in the same amplifier. Since SV0401 is caused by a servo alarm occurred on an axis in another path, SV0007 is caused together to clearly indicate the fact. The axis belonging to another path in the same amplifier resolves the cause of the servo alarm
- SV0301Error codeSince the absolute-position detector caused a communication error, the correct machine position could not be obtained. (data transfer error) The absolute-position detector, cable, or servo interface module is thought to be defective
- SV0302Error codeSince the absolute-position detector caused an overtime error, the correct machine position could not be obtained. (data transfer error) The absolute-position detector, cable, or servo interface module is thought to be defective
- SV0303Error codeSince the absolute-position detector caused a framing error, the correct machine position could not be obtained. (data transfer error) The absolute-position detector, cable, or servo interface module is thought to be defective
- SV0304Error codeSince the absolute-position detector caused a parity error, the correct machine position could not be obtained. (data transfer error) The absolute-position detector, cable, or servo interface module is thought to be defective
- SV0305Error codeSince the absolute-position detector caused a pulse error, the correct machine position could not be obtained. The absolute-position detector, or cable is thought to be defective
- SV0360Error codeThe checksum alarm occurred on the built-in Pulsecoder
- SV0361Error codeThe phase data abnormal alarm occurred on the built-in Pulsecoder
- SV0362Error codeThe speed count abnormal alarm occurred on the built-in Pulsecoder
- SV0363Error codeThe clock alarm occurred on the built-in Pulsecoder
- SV0364Error codeA digital servo soft detected an abnormality on the built in Pulsecoder
- SV0365Error codeThe digital servo software detected abnormal data on the built-in Pulsecoder
- SV0366Error codeA pulse error occurred on the built-in Pulsecoder
- SV0367Error codeA count error occurred on the built-in Pulsecoder
- SV0368Error codeThe communications data could not be received from the built-in Pulsecoder
- SV0369Error codeA CRC error or stop bit error occurred in the communications data from the built-in Pulsecoder
- SV0380Error codeSeparate detector error
- SV0381Error codeAn abnormal alarm in the position data occurred on the separate detector
- SV0382Error codeA count error occurred on the separate detector
- SV0383Error codeA pulse error occurred on the separate detector
- SV0384Error codeThe digital servo software detected abnormal data on the separate detector
- SV0385Error codeThe communications data could not be received from the separate detector
- SV0386Error codeA CRC error or stop bit error occurred in the communications data from the standalone detector
- SV0387Error codeAn abnormality occurred on a separate detector. For more information, contact the scale manufacturer
- SV0409Error codeAn abnormal load was detected on the servo motor, during Cs axis, or spindle positioning (T series) axis. The alarm can be canceled by RESET
- SV0417ParameterA digital serve parameter setting is incorrect. [When bit 4 of diagnosis information No. 203 is 1.] An illegal parameter was detected by the servo software. Identify the cause with reference to diagnosis information No. 352. [When bit 4 of diagnosis information No. 203 is 0.] The CNC software detected an illegal parameter. Probable causes are given below (see diagnosis information No. 280). 1) The value specified in parameter No. 2020 as the motor model falls outside the specified range. 2) The motor rotation direction in parameter No. 2022 is not set to a correct value (111 or -111). 3) The speed feedback pulse count per motor rotation in parameter No. 2023 is set to a negative or other incorrect value. 4) The position feedback pulse count per motor rotation in parameter No. 2024 is set to a negative or other incorrect value
- SV0420Error codeIn feed axis control , for synchronization, the difference value of torque between a master and slave axes exceeded the parameter (No. 2031) setting value. This alarm occurs for a master axis
- SV0430Error codeThe servo motor has overheated
- SV0431Error codePower Supply (PS) : Overheat Servo Amplifier : Overheat
- SV0432Error codePower Supply (PS) : The control power supply voltage has dropped. Servo Amplifier : The control power supply voltage has dropped
- SV0433Error codePower Supply (PS) : Low DC link voltage Servo Amplifier : Low DC link voltage
- SV0434Error codeServo Amplifier : Low control power voltage
- SV0435Error codeServo Amplifier : Low DC link voltage
- SV0438Error codeServo Amplifier : Motor overcurrent
- SV0439Error codePower Supply (PS) : The DC link voltage is too high. Servo Amplifier : The DC link voltage is too high
- SV0440Error codePower Supply (PS) : Excessive generative discharge Servo Amplifier : Excessive generative discharge, or abnormal error in generative power circuit
- SV0441Error codeThe digital servo software detected an abnormality in the motor current detection circuit
- SV0442Error codePower Supply (PS) : The spare charge circuit for the DC link is abnormal
- SV0443Error codePower Supply (PS) : Internal cooling fan failure. Servo Amplifier : Internal cooling fan failure
- SV0444Error codeServo Amplifier : Internal cooling fan failure
- SV0449Error codeServo Amplifier : The IPM (Intelligent Power Module) detected an alarm
- SV0453Error codeSoftware disconnection alarm of the α Pulsecoder. Turn off the power to the CNC, then remove and insert the Pulsecoder cable. If this alarm is issued again, replace the Pulsecoder
- SV0454Error codeThe magnetic pole detection function terminated abnormally. The magnetic pole could not be detected because the motor did not run